Objects pane GR-185Kind• FreezeFreezes the signal or net at the specified value until it is forced again or until it is unforcedwith a noforce command (CR-200).Freeze is the default for Verilog nets and unresolved VHDL signals and Drive is thedefault for resolved signals.If you prefer Freeze as the default for resolved and unresolved signals, you can changethe default force kind in the modelsim.ini file (see "Control variables located in INI files"(UM-502)).• DriveAttaches a driver to the signal and drives the specified value until the signal or net isforced again or until it is unforced with a noforce command (CR-200). This type of forceis illegal for unresolved VHDL signals.• DepositSets the signal or net to the specified value. The value remains until there is a subsequentdriver transaction, or until the signal or net is forced again, or until it is unforced with anoforce command (CR-200).• Delay ForAllows you to specify how many time units from the current time the stimulus is to beapplied.• Cancel AfterCancels the force after the specified period of simulation time.<strong>ModelSim</strong> <strong>SE</strong> <strong>GUI</strong> <strong>Reference</strong>