Catalog: ET115.26-EG7 (908)TABLE OF CONTENTS<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Construction Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Standard and Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Coils, Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Electric Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<strong>Fan</strong> Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Motor, <strong>Fan</strong> and Sound Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Guide Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19NOTES:• ENVIRO-TEC ® offers Web-Select ® , the industry’s first web-based rating and selection program for completeunit, <strong>coil</strong> and sound selection. See your representative for more information.• Some drawings are not shown in this catalog.• All data herein is subject to change without notice.• Drawings not for installation purposes; refer to IOM manual.• ETL Report Number 539840.• City of New York Material and Equipment Acceptance (MEA) File Numbers:- <strong>HL</strong>F and <strong>HL</strong>P: MEA 53-98-E- <strong>HL</strong>E: MEA 53-98-E Vol. II .2 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)FEATURES AND BENEFITSHIGH PERFORMANCEENVIRO-TEC ® <strong>HL</strong> Series horizontal low profile fan <strong>coil</strong>units are designed to maximize flexibility of selectionand installation.The units are also designed to exceed the stringentquality standards of the institutional market, whileremaining cost competitive in the light commercial segmentof the market.ENVIRO-TEC ® horizontal fan <strong>coil</strong> units set the newstandards for quality, flexibility, and competitive pricing.DESIGN FLEXIBILITYThe extensive variety of standard options available onthe <strong>HL</strong> Series units are where you find the versatility tofit any HVAC system designer’s needs.Options include: rear or bottom ducted return, foil facedor elastomeric closed cell foam insulation, solid or telescopingbottom panels for unit recessing, single wallstainless steel drain pans, electric heat with single pointpower connection. All electric heat units are listed withETL as an assembly and carry the cETL label.All units comply with the latest edition of ARI Standard440 for testing and rating fan <strong>coil</strong> units, are certified,and display the ARI symbol.High Efficiency motors, fan relays, disconnects andfusing mean easier coordination between mechanicaland electrical trades.Coil options allow for three or four row chilled water orDX cooling <strong>coil</strong>s. One or two row hot water or standardsteam <strong>coil</strong>s may be placed in the preheat or reheatposition.All units are thoroughly inspected and tested prior toshipment, eliminating potential problems at startup.Motor wiring is brought to a junction box on the outsideof the unit casing, reducing electrical hook-up time.Plenum units are field reversible for either rear or bottomreturn without special adapters, tools or additionalparts.All <strong>HL</strong> Series fan <strong>coil</strong> units have the option of a hingedcover electrical enclosure in the bottom of the unit. Theexpansive compartment allows for easy access to allelectrical components, terminal blocks and wiring.Factory furnished valve packages assure proper fit,operation and performance.For fast track jobs, the <strong>HL</strong> Series fan <strong>coil</strong> is availableon Quick Ship with 5, 10 or 15 day lead times.QUALITY PRODUCTConcealed Model <strong>HL</strong> Series fan <strong>coil</strong> units are built fromgalvanized steel. This metal surpasses the ASTM 125hour salt spray test for corrosion and rust. ExposedModel <strong>HL</strong>E cabinetry is powder coated galvannealedsteel.Standard insulation is 1/2 inch thick fiberglass, complyingwith UL 181 and NFPA 90A. Optional foil faced or elastomericclosed cell foam insulation may be specified.All units, with or without electric heat, are cETL listedand labeled. All wiring is in compliance with NEC, assuringsafety and quality for the owner.<strong>HL</strong> Series fan <strong>coil</strong> units have a removable fan assembly.The entire fan assembly can be removed from the unitand serviced easily on a workbench.Silent solid state relays are available for fan and electricheat control in sound sensitive environments.CONVENIENT INSTALLATIONAll <strong>HL</strong> Series fan <strong>coil</strong> units are shipped completelyassembled, reducing field installation time and labor.ENVIRO-TEC 3


Catalog: ET115.26-EG7 (908)CONSTRUCTION FEATURES<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>MODEL <strong>HL</strong>P<strong>HL</strong> Series fan <strong>coil</strong>s have many standard and optional features which are unique to the industry(see page 6 for a complete listing).1/2" thick fiberglass insulation(standard), or foil faced orelastomeric closed cell foaminsulation (optional)Galvanized steel casing withstanding125 hour salt spray test per ASTM B-1171 1/2" duct collar allows quick fieldconnection of duct workETL and ARI 440listed and labeledIntegral filter rack with 1"filter and integral rearducted (shown) orbottom return onall plenum unitsPermanently lubricated,three tap, PSC fanmotors designed forquiet and efficientoperationSingle point powerconnection on all unitswith electric heatOptionalsecondary drainconnection foradded security(not shown)Removable fan board for completebottom or rear access and servicingOptional electricresistance heat is ETLlisted as an assemblyfor safety complianceEntire electric heat assembly can be removedfrom the bottom for servicingOptional hinged coverelectrical enclosureallows easy bottomaccess to all electricalcomponentsSingle wall galvanized orstainless steel (optional)drain pans are positivelysloped to drain connectionsDrain pans can beeasily removed forcleaning, and reversedfor opposite side drainconnectionsChilled water or DX cooling<strong>coil</strong>s up to 4 rowsHot water heating <strong>coil</strong>s orsteam <strong>coil</strong>s up to 2 rowscan be mounted in the preheator reheat positionBottom access to bothentering and leaving sidesof all <strong>coil</strong>s for cleaningMaximum 6 total rowsof <strong>coil</strong> combinedMODEL <strong>HL</strong>E<strong>Horizontal</strong> Exposed CabinetMODEL <strong>HL</strong>F<strong>Horizontal</strong> Free Return4 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)CONSTRUCTION FEATURESMODELS <strong>HL</strong>F/<strong>HL</strong>P/<strong>HL</strong>EELECTRICAL ENCLOSUREThe bottom hinged electrical enclosure provides accessto a spacious electrical compartment. This compartmenthouses all electric heat and control components.Terminal strips are furnished for simple power andcontrol wiring connections. Multiple knockouts allowwiring entries from either side of the compartment.DRAIN PANStandard drain pans are externally insulated, single wallgalvanized steel with an option for stainless steel. Drainpans are available with secondary drain connection.On concealed models, the <strong>HL</strong> Series drain pan is easilyremovable for cleaning or reversing connections.TELESCOPING BOTTOM PANELThe telescoping bottom panel allows for fully recessingthe unit while permitting service access into the ceilingplenum. The architectural ceiling panel is finished witha durable powder coat paint.FILTERSOne inch throwaway filters are tight fitting to prevent airbypass. Filters are easily removable from the bottomthrough the access panel or plenum.COILSAll fan <strong>coil</strong>s are available in 2 or 4 pipe configurations.The heating <strong>coil</strong> may be placed in the reheat or preheatposition. On concealed models, heating and cooling<strong>coil</strong>s are available with right, left or opposite sideconnections.FAN DECKThe fan assembly is easily removed withoutdisconnecting the ductwork for service access to motorsand blowers at, or away from the unit.ENVIRO-TEC 5


Catalog: ET115.26-EG7 (908)STANDARD AND OPTIONAL FEATURES<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>STANDARD FEATURESConstructionAll <strong>Units</strong>• ARI 440 certified and labeled• Galvanized steel construction• 1/2" thick fiberglass insulation• 1 1/2" duct discharge collar• Four point hanger mounting bracketsPlenum units• Integral filter rack with 1" throwaway filter• Integral rear ducted return - field reversibleto bottom returnExposed units• Stamped louver supply and return air grilles• Durable powder coat paint• 18 gauge bottom panel constructionCoils• Cooling - 3 or 4 row chilled water or DX, heat pump compatible• Heating - 1 or 2 row hot water or steam – reheat or preheatposition• 6 total rows of cooling and heating <strong>coil</strong>s maximum• 1/2" O.D. seamless copper tubes• 0.016" tube wall thickness• High efficiency aluminum fin surface for optimizing heattransfer, pressure drop and carryover• Left or right hand, same or opposite sideconnections• Access to entering and leaving air sides forcleaning• Removable for service• Manual air ventsDrain Pans• Single wall, galvanized steel, externally insulated – fireretardant and antimicrobial• Positively sloped to drain connection• Removable, field reversible• 7/8" O.D. primary drain connection<strong>Fan</strong> Assemblies• Forwardly curved, DWDI centrifugal type• 115 volt, single phase, three tap PSC motors• Quick disconnect motor connections• Removable fan/motor deck for serviceElectrical• cETL listed for safety compliance• Electrical junction box for field wiring terminations• Terminal block for field connectionsElectric Heat• ETL listed as an assembly for safety compliance• Integral electric heat assembly with removableelements for easy service• reset primary and back-up secondarythermal limits• Single point power connection• Bottom hinged electrical enclosureOPTIONAL FEATURESConstructionAll units• Foil faced fiberglass insulation• Elastomeric closed cell foam insulationPlenum units• Bottom return• 1" pleated filters (MERV 6)• Spare 1" throwaway filters• Telescoping Bottom PanelsExposed units• 1" pleated filters (MERV 6)• Double deflection discharge grille• Ducted supply and/or returnCoils• Automatic air vents• Stainless steel <strong>coil</strong> casings• 0.025" tube wall (standard on steam)Drain Pans• Stainless steel construction with external insulation• 5/8" O.D. secondary drain connection• Auxiliary drip pans, galvanized or stainless steel<strong>Fan</strong> Assemblies• 208-230, 220 & 277 volt, single phase, three tap PSCmotorsElectrical• Bottom hinged cover electrical enclosure• SCR fan speed controller• <strong>Fan</strong> relay packages• Silent solid state fan relays• Toggle disconnect switch• Condensate overflow switch (drain pan)• Main fusing• Unit and remote mounted three speed fan switchesElectric Heat• Manual reset secondary thermal limits• Door interlocking disconnect switches• Main fusing• Silent relay/contactorsPiping Packages• Factory assembled – shipped loose for field installation• 1/2" and 3/4", 2 way and 3 way normally closed, twoposition electric motorized valves• Isolation ball valves with memory stop• Fixed and adjustable flow control devices• Unions and P/T ports• Floating point modulating control valves• High pressure close-off actuators(1/2" = 50 PSIG; 3/4" = 25 PSIG)Thermostats• Remote mounted analog, digital display orprogrammable• 2 and 4 pipe control sequences• Automatic and manual changeover• Integral three speed fan switches6 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)COILS, PHYSICAL DATACOILSENVIRO-TEC ® offers hot water, chilled water, direct expansion (DX), and standard steam <strong>coil</strong>s for specific applicationwith all <strong>HL</strong> Series <strong>Fan</strong> Coil <strong>Units</strong>. Strict on-site inspection before, during, and after installation guarantees thehighest quality and performance available.STANDARD FEATURES• Cooling - 3 or 4 row chilled water or DX• Heating - 1, 2, 3 or 4 row hot water or, 1 or 2 row steam• 6 total rows of cooling and heating <strong>coil</strong>s maximum• 1/2" O.D. seamless copper tubes• 0.016" tube wall thickness• High efficiency aluminum fin surface for optimizing heat transfer,pressure drop and carryover• Left or right hand, same or opposite side connections• Manual air ventsOPTIONAL FEATURES• Automatic air vents• Stainless steel <strong>coil</strong> casings• 0.025" tube wall thickness(standard on steam <strong>coil</strong>s)• DX <strong>coil</strong>s are heat pump compatibleENVIRO-TEC ® offers Web-Select, the industry’s first web-based fan <strong>coil</strong> rating and selection program for completeunit, <strong>coil</strong> and sound selection. See your representative for more information.UNITSIZE202530405060COILFACEAREA1.04[.09]1.35[.13]1.56[.14]2.08[.19]2.60[.24]3.13[.29]RETURN AIRGRILLEFREE AREASUPPLY AIRGRILLEFREE AREAMODEL <strong>HL</strong>EFILTERFACEAREA0.47 [.04] 0.40 [.04] 1.77 [.16]0.58 [.05] 0.50 [.05] 2.36 [.22]0.68 [.06] 0.56 [.05] 2.36 [.22]0.81 [.08] 0.80 [.07] 2.95 [.27]1.01 [.09] 0.96 [.09] 3.54 [.33]1.15 [.11] 1.20 [.11] 4.13 [.38]NOMINAL FILTERSIZES30 x 8.5 x 1[762 x 216 x 25](2) 20 x 8.5 x 1[508 x 216 x 25](2) 20 x 8.5 x 1[508 x 216 x 25](1) 20, (1) 30 x 8.5 x 1[508, 762 x 216 x 25](2) 30 x 8.5 x 1[762 x 216 x 25](2) 20, (1) 30 x 8.5 x 1[508, 762 x 216 x 25]FILTERFACEAREA1.18[.11]1.54[.14]1.77[.16]2.36[.22]2.95[.27]3.54[.33]MODEL <strong>HL</strong>PNOMINAL FILTERSIZES20 x 8.5 x 1[508 x 216 x 25]26 x 8.5 x 1[660 x 216 x 25]30 x 8.5 x 1[762 x 216 x 25](2) 20 x 8.5 x 1[508 x 216 x 25](1) 20, (1) 30 x 8.5 x 1[508, 762 x 216 x 25](2) 30 x 8.5 x 1[762 x 216 x 25]NOTES:1. Face and free areas are in square feet [square meters].2. Filter sizes are in inches [millimeters].3. Return Air Grille Free Area applies to <strong>HL</strong>E and Telescoping Bottom Panel return grilles.4. Supply Air Grille Free Area applies to <strong>HL</strong>E supply grille and minimum free area allowable for a supply grille supplied byothers.ENVIRO-TEC 7


Catalog: ET115.26-EG7 (908)<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>PHYSICAL DATAMODEL / SIZE<strong>HL</strong>F 20<strong>HL</strong>F 25<strong>HL</strong>F 30<strong>HL</strong>F 40<strong>HL</strong>F 50<strong>HL</strong>F 60<strong>HL</strong>F 20<strong>HL</strong>F 25<strong>HL</strong>F 30<strong>HL</strong>F 40<strong>HL</strong>F 50<strong>HL</strong>F 60<strong>HL</strong>P 20<strong>HL</strong>P 25<strong>HL</strong>P 30<strong>HL</strong>P 40<strong>HL</strong>P 50<strong>HL</strong>P 60<strong>HL</strong>P 20<strong>HL</strong>P 25<strong>HL</strong>P 30<strong>HL</strong>P 40<strong>HL</strong>P 50<strong>HL</strong>P 60<strong>HL</strong>E 20<strong>HL</strong>E 25<strong>HL</strong>E 30<strong>HL</strong>E 40<strong>HL</strong>E 50<strong>HL</strong>E 60<strong>HL</strong>E 20<strong>HL</strong>E 25<strong>HL</strong>E 30<strong>HL</strong>E 40<strong>HL</strong>E 50<strong>HL</strong>E 60Rows333333444444333333444444333333444444COILFPI101010101010101010101010101010101010101010101010101010101010101010101010ARI STANDARD RATINGSAIRFLOWCFM(Dry Flow)330450640800114015903204306107801040151027042054077010101460260410520740970137024031045065082011302403004406307801040COOLINGCAPACITYQT(BTUH)8000115001320018500240003400085001160015900222002850041400690010900119001810022300323008800109001510021300272003860063008900104001630019500275006300870012800189002340031900QS(BTUH)59008500990014300193002650060008600104001660022500313005300810081001390018200256006000810010300159002140028400480065007100124001570021500470063008300140001830024200Flow Rate(GPM)1.82.63.24.25.47.61.82.63.94.96.49.21.62.52.84.15.07.21.62.53.54.86.18.61.52.02.53.74.46.1WATERWPDft-wg1.63.47.63.77.414.63.16.610.97.212.927.11.23.16.13.57.113.32.56.010.06.911.923.81.12.24.92.95.610.0POWERINPUT(WATTS)NOTE: Based on 80°F DB and 67°F WB EAT, 45°F EWT, 10°F temperature rise, high fan speed. Motor type is PSC andmotor voltage is 115/1/60. Airflow under dry <strong>coil</strong> conditions. Models <strong>HL</strong>E tested at 0.0" external static pressure. Models <strong>HL</strong><strong>Fan</strong>d <strong>HL</strong>P tested at 0.05" external static pressure.1.52.03.14.25.37.12.14.07.95.59.116.88113815226340248977135151261380466811321522633724897713015126136146675127135245337402651251302353213838 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)PHYSICAL DATAUNIT TYPE<strong>HL</strong>P<strong>HL</strong>F<strong>HL</strong>EUNIT SIZENOMINALCFMHEATING CAPACITY1 ROW 2 ROWQS (MBH) GPM WPD QS (MBH) GPM WPD20 250 8.6 0.4 0.2 15.7 0.8 0.925 400 15.0 0.6 0.6 21.0 1.1 3.130 500 16.1 0.8 0.6 29.2 1.5 3.240 750 23.6 1.2 1.5 40.5 2.1 1.650 1000 28.7 1.5 0.7 53.7 2.7 2.960 1400 36.1 1.9 1.1 66.9 3.4 4.720 250 7.9 0.4 0.3 14.0 0.8 1.525 350 10.8 0.6 0.5 19.3 1.0 2.630 450 13.5 0.7 0.9 24.0 1.3 4.840 650 20.4 1.1 2.0 34.0 1.8 1.750 850 22.5 1.2 0.7 40.7 2.1 3.160 1200 30.9 1.6 1.2 55.4 2.9 5.5NOTE: Based on 70°F DB EAT, 180°F EWT, 40°F temperature drop, high fan speed.COILROWSNOTE: Unit weight data is in pounds [kilograms].UNIT WEIGHT DATACOMPONENTUNIT SIZE20 25 30 40 50 60<strong>HL</strong>F BASE UNIT 40 [18] 51 [23] 59 [27] 69 [31] 91 [41] 111 [50]<strong>HL</strong>P BASE UNIT 45 [20] 56 [25] 65 [30] 80 [36] 103 [47] 123 [56]<strong>HL</strong>E BASE UNIT 119 [54] 138 [63] 155 [70] 181 [82] 220 [100] 257 [117]1 ROW - DRY 8 [4] 10 [5] 11 [5] 13 [6] 15 [7] 18 [8]1 ROW - WET 10 [5] 12 [5] 13 [6] 15 [7] 18 [8] 21 [10]2 ROW - DRY 11 [5] 13 [6] 15 [7] 18 [8] 22 [10] 26 [12]2 ROW - WET 14 [6] 16 [7] 18 [8] 22 [10] 27 [12] 32 [15]3 ROW - DRY 14 [6] 17 [8] 19 [9] 24 [11] 29 [13] 34 [15]3 ROW - WET 17 [8] 21 [10] 24 [11] 30 [14] 36 [16] 42 [19]4 ROW - DRY 17 [8] 20 [9] 23 [10] 29 [13] 36 [16] 42 [19]4 ROW - WET 21 [10] 25 [11] 29 [13] 36 [16] 45 [20] 53 [24]ENVIRO-TEC 9


Catalog: ET115.26-EG7 (908)ELECTRIC HEAT<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>ENVIRO-TEC ® offers electric heating <strong>coil</strong>s for specific application with all <strong>HL</strong> Series <strong>Fan</strong> Coil units. This allows theflexibility to provide an unrivaled amount of electric heat options in one complete package.STANDARD FEATURES• ETL listed as an assemblyfor safety compliance• Single point power connection• Mounted in preheat position• Automatic reset primary and back-upsecondary thermal limits• Internal wiring rated at 105°C• Integral electric heat assembly withremovable element for easy service• Stainless steel terminals and hardwareOPTIONAL FEATURES• Silent solid state relays• Manual reset secondary limits• Door interlocking disconnect switch• Main fusingUSEFUL FORMULASkW* = CFM x ΔT x 1.085**34131Ø AMPs = kW x 1000Volts* 1kW = 3413 BTU/H** Capacity at sea levelAltitude Considerations:Reduce by 0.034 for each 1000 ft. of altitudeabove sea level.Example: 5000 ft./1000 ft. = 55 x 0.034 = 0.171.085 - 0.17 = 0.915ELECTRICAL CALCULATIONS INFORMATION1. Refer to MCA/MOP calculator at www.enviro-tec.com for MCA and/or MOP calculations.2. Non-Fused Door Interlock Disconnect Switch shall be sized according to MCA.3. Fused Door Interlock Disconnect Switch and Main Fusing shall be sized according to MOP.UNITSIZE2025304050ELECTRIC HEAT SELECTION CHART (AMPS)MBH 5.1 6.8 10.2 13.7 17.1 20.5 25.6 27.3 34.1KW 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0VOLTSAMPS115 13.0 17.4 26.1208 7.2 9.6 14.4230 6.5 8.7 13.0277 5.4 7.2 10.8115 13.0 17.4 26.1208 7.2 9.6 14.4230 6.5 8.7 13.0277 5.4 7.2 10.8115 13.0 17.4 26.1 34.8 43.5208 7.2 9.6 14.4 19.2 24.0 28.8230 6.5 8.7 13.1 17.4 21.7 26.1277 5.4 7.2 10.8 14.4 18.1 21.7115 17.4 26.1 34.8 43.5208 9.6 14.4 19.2 24.0 28.8 33.7230 8.7 13.1 17.4 21.7 26.1 30.4277 7.2 10.8 14.4 18.1 21.7 25.3115 26.1 34.8 43.5208 14.4 19.2 24.0 28.8 33.7 38.5230 13.1 17.4 21.7 26.1 30.4 34.8277 10.8 14.4 18.1 21.7 25.3 28.9115 26.1 34.8 43.5208 14.4 19.2 24.0 28.8 33.7 38.560230 13.1 17.4 21.7 26.1 30.4 34.8 43.5277 10.8 14.4 18.1 21.7 25.3 28.9 36.1NOTES:1. Shaded areas of the electric heat selection chart indicate kW and voltage options not available.2. Available voltages are single phase, 60 hertz.3. Size heater for Leaving Air Temperature (LAT) less than 104°F.4. Silent, solid state heater relay is available for sound sensitive environments.5. Ask your ENVIRO-TEC ® representative about continuously modulating electric heat using SSR and special control options.10 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)FAN PERFORMANCE CURVES1. <strong>Fan</strong> curves on the following pages depict actual performance of each motor tap without any additional fan balance adjustment.Actual capacities which fall below each curve can be obtained by adding an adjustment device. <strong>Units</strong> should not berun prior to installation of downstream ductwork; otherwise, damage to the motor may result.2. ENVIRO-TEC ® <strong>Fan</strong> Coil <strong>Units</strong> are equipped with permanent split-capacitor (PSC) motors with three taps (High, Medium and<strong>Low</strong>) which provides variable horsepower outputs. Most often, size selections are conservative and actual CFM requirementsand/or external static pressure requirements are lower than those specified. In this case, the unit fan motor can be run at lowor medium tap, substantially reducing the operating cost of the unit.3. All fan curves are for 115/1/60 motors and include pressure losses for cabinet, electric heater, and 3 or 4 row <strong>coil</strong>. Plenumunits include a clean 1" throwaway filter. For other <strong>coil</strong> configurations, adjust performance curves based on pressure lossesfor the <strong>coil</strong>s using Web-Select ® .4. See page 14 for fan motor electrical data.5. For additional high static pressure applications and rating points, contact factory.Size 20Size 250.40Model <strong>HL</strong>P (Plenum)0.80Model <strong>HL</strong>P (Plenum)0.35HIGH0.700.30MED0.60ESP (IN. W.G.)0.250.200.15LOWESP (IN. W.G.)0.500.400.30MEDHIGH0.100.20LOW0.050.100.000 50 100 150 200 250 300SCFM3 ROW COIL4 ROW COIL0.000 50 100 150 200 250 300 350 400 450 500SCFM3 COILROW4 ROW COIL0.40Model <strong>HL</strong>F (Free Return)0.80Model <strong>HL</strong>F (Free Return)0.35HIGH0.700.30MEDLOW0.60HIGHESP (IN. W.G.)0.250.200.15ESP (IN. W.G.)0.500.400.30LOWMED0.100.200.050.100.000 50 100 150 200 250 300 350 400SCFM3 ROW COIL4 ROW COIL0.000 50 100 150 200 250 300 350 400 450 500SCFM3 ROW COIL4 ROW COIL0.40Model <strong>HL</strong>E (Exposed Cabinet)0.70Model <strong>HL</strong>E (Exposed Cabinet)0.350.60HIGH0.300.50MEDESP (IN. W.G.)0.250.200.15ESP (IN. W.G.)0.400.30LOW0.100.200.05HIGHMEDLOW0.000 50 100 150 200 250 3003 ROW COILSCFM4 ROW COIL0.100.000 50 100 150 200 250 300 350SCFM3 ROW COIL4 ROW COILENVIRO-TEC 11


Catalog: ET115.26-EG7 (908)FAN PERFORMANCE CURVESSize 30<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>Size 40Model <strong>HL</strong>P (Plenum)Model <strong>HL</strong>P (Plenum)0.350.80ESP (IN. W.G.)0.300.250.200.15HIGHMEDLOWESP (IN. W.G.)0.700.600.500.400.30HIGHMED0.100.200.050.10LOW0.000 50 100 150 200 250 300 350 400 450 500 550 600SCFM3 ROW COIL4 ROW COIL0.000 100 200 300 400 500 600 700 800 900SCFM3 ROW COIL4 ROW COIL0.40Model <strong>HL</strong>F (Free Return)0.90Model <strong>HL</strong>F (Free Return)ESP (IN. W.G.)0.350.300.250.200.15HIGHMEDLOWESP (IN. W.G.)0.800.700.600.500.400.30HIGHMED0.100.200.050.10LOW0.000 50 100 150 200 250 300 350 400 450 500 550 600 650 700SCFM3 ROW COIL4 ROW COIL0.000 100 200 300 400 500 600 700 800 900SCFM3 ROW COIL4 ROW COIL0.40Model <strong>HL</strong>E (Exposed Cabinet)0.80Model <strong>HL</strong>E (Exposed Cabinet)0.350.700.300.60ESP (IN. W.G.)0.250.200.15ESP (IN. W.G.)0.500.400.300.100.20HIGH0.05MEDLOW0.000 50 100 150 200 250 300 350 400 450 5003 ROW COILSCFM4 ROW COIL0.10MEDHIG<strong>HL</strong>OW0.000 50 100 150 200The thick 250 line 300 indicates 350 3 row 400<strong>coil</strong>450 500 550 600 650 7003 ROW COILSCFM4 ROW COIL12 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)FAN PERFORMANCE CURVESSize 50Size 60Model <strong>HL</strong>P (Plenum)Model <strong>HL</strong>P (Plenum)0.800.900.700.80HIGH0.600.70MEDESP (IN. W.G.)0.500.400.30MEDHIGHESP (IN. W.G.)0.600.500.400.30LOW0.200.200.10LOW0.100.000 200 400 600 800 1000 1200SCFM3 ROW COIL4 ROW COIL0.000 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600SCFM3 ROW COIL4 ROW COILModel <strong>HL</strong>F (Free Return)Model <strong>HL</strong>F (Free Return)1.000.900.900.80HIGH0.800.70HIGH0.70MED0.60MEDESP (IN. W.G.)0.600.500.400.30LOWESP (IN. W.G.)0.500.400.300.200.20LOW0.100.100.000 200 400 600 800 1000 1200 1400SCFM3 ROW COIL4 ROW COIL0.000 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700SCFM3 ROW COIL4 ROW COIL0.90Model <strong>HL</strong>E (Exposed Cabinet)0.80Model <strong>HL</strong>E (Exposed Cabinet)0.800.700.700.600.60ESP (IN. W.G.)0.500.40ESP (IN. W.G.)0.500.400.300.30HIGHHIGH0.20MED0.20MED0.10LOW0.10LOW0.000 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 8503 ROW COILSCFM4 ROW COIL0.000 100 200 300 400 500 600 700 800 900 1000 1100 12003 ROW COILSCFM4 ROW COILENVIRO-TEC 13


Catalog: ET115.26-EG7 (908)MOTOR, FAN AND SOUND DATA<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>UNITSIZE202530405060MOTOR AND FAN DATAFAN MOTOR # OF 115 VOLTS 208-230 VOLTS 277 VOLTSSPEED H.P. (QTY.) FANS AMPS WATTS AMPS WATTS AMPS WATTSHigh (1) 1/300.8 57 0.6 77 0.3 71Medium (1) 1/50 1 0.4 39 0.3 49 0.3 48<strong>Low</strong> (1) 1/60 0.3 33 0.3 43 0.3 41High (1) 1/151.1 125 0.5 120 0.5 120Medium (1) 1/30 1 0.9 90 0.3 80 0.3 80<strong>Low</strong> (1) 1/60 0.5 60 0.2 60 0.2 60High (1) 1/101.9 165 0.8 158 0.8 162Meduim (1) 1/30 2 0.8 76 0.3 75 0.5 65<strong>Low</strong> (1) 1/60 0.5 47 0.2 54 0.4 41High (1) 1/62.5 261 1.4 284 1.0 254Medium (1) 1/12 2 1.5 162 0.5 171 0.5 152<strong>Low</strong> (1) 1/40 0.6 75 0.4 79 0.3 74High(1) 1/81.6 215 0.9 216 0.8 214(1) 1/6 2.5 257 1.4 233 1.0 255Medium(1) 1/15 1.3 145 0.6 109 0.5 1323(1) 1/12 1.5 156 0.5 106 0.5 151<strong>Low</strong>(1) 1/40 0.8 69 0.3 63 0.3 86(1) 1/40 0.6 75 0.4 62 0.3 84High (2) 1/65.0 522 2.8 568 2.0 508Medium (2)1/12 4 3.0 324 1.0 342 1.0 304<strong>Low</strong> (2) 1/40 1.2 150 0.6 158 0.6 148NOTES:1. Motor electrical data is nameplated data. Actual data will vary with application.2. 230 volt motor is nameplated for 208-230/1/60. Use 230 volt motor data for 208 volt applications.3. Unit size 30, 208-230 and 277 volt motors are 1/12 HP at high tap.SOUND DATATOTAL SOUND POWER LEVELUNIT SIZE FAN SPEED SCFMOCTAVE BAND / CENTER FREQUENCY (HZ)2/125 3/250 4/500 5/1000 6/2000 7/4000 8/8000High 282 55 59 53 50 46 38 3620 Medium 216 50 52 47 44 38 31 32<strong>Low</strong> 175 47 48 43 39 32 27 31High 420 58 62 57 54 51 44 3925 Medium 286 53 53 49 45 41 34 29<strong>Low</strong> 180 48 42 38 36 33 27 27High 522 60 60 57 56 50 44 4030 Medium 458 57 55 54 52 46 40 36<strong>Low</strong> 269 48 44 43 39 32 27 31High 810 65 68 64 60 55 51 4740 Medium 565 59 59 57 51 46 40 35<strong>Low</strong> 300 51 46 41 36 28 27 30High 1050 61 66 68 62 56 52 4950 Medium 840 56 61 63 55 49 44 40<strong>Low</strong> 490 48 53 59 46 39 33 32High 1400 67 72 70 68 59 54 5160 Medium 1050 61 65 67 57 52 47 42<strong>Low</strong> 500 50 56 48 40 33 28 31NOTES:1. Sound data tested in accordance with ARI 350-2000.2. Sound levels are expressed in decibels, dB RE: 1 x 10 -12 watts.3. Total sound power level data based on Model <strong>HL</strong>P with fan CFM at corresponding motor tap with 115/1/60 volt motor, 3 or4 row <strong>coil</strong>, 1" throwaway filter, 0.0" external static pressure and standard rated internal pressure losses.14 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)DIMENSIONAL DATAMODEL <strong>HL</strong>F FREE RETURN UNITSDrawings are not to scale and not for submittal or installation purposes.ENVIRO-TEC 15


Catalog: ET115.26-EG7 (908)DIMENSIONAL DATA<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>MODEL <strong>HL</strong>P PLENUM UNITSDrawings are not to scale and not for submittal or installation purposes.16 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)DIMENSIONAL DATAMODEL <strong>HL</strong>E EXPOSED CABINET UNITSDrawings are not to scale and not for submittal or installation purposes.ENVIRO-TEC 17


Catalog: ET115.26-EG7 (908)DIMENSIONAL DATA<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>TELESCOPING BOTTOM PANELDrawings are not to scale and not for submittal or installation purposes.18 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)GUIDE SPECIFICATIONSGENERALFurnish and install ENVIRO-TEC ® Model <strong>HL</strong> <strong>Horizontal</strong>Concealed Direct Drive <strong>Fan</strong> Coil <strong>Units</strong> where indicatedon the plans and in the specifications. <strong>Units</strong> shall becompletely factory assembled, tested and shipped asone piece. All units shall be capable of meeting orexceeding the scheduled capacities for cooling, heatingand air delivery. All unit dimensions for each model andsize shall be considered maximums. <strong>Units</strong> shall be ETLlisted in compliance with UL/ANSI Standard 1995, andbe certified as complying with the latest edition of ARIStandard 440.CONSTRUCTIONAll unit chassis shall be fabricated of heavy gaugegalvanized steel panels able to meet 125 hour saltspray test per ASTM B-117. All exterior panels shallbe insulated with 1/2" thick insulation with a maximumk value of .24 (BTU • in) / (hr • ft 2 • °F) and rated fora maximum air velocity of 5000 f.p.m. Insulation mustmeet all requirements of ASTM C1071 (includingC665), UL 181 for erosion, and carry a 25/50 ratingfor flame spread/smoke developed per ASTM E-84,UL 723 and NFPA 90A.All concealed units shall have a minimum 1-1/2" ductcollar on the discharge. Plenum and exposed unitsshall have a minimum 3/4" duct collar on the return.All exposed units shall have exterior panels fabricatedof galvannealed steel. The fan and filter bottomaccess panel shall be attached with quarter turn quickopen fasteners to allow for easy removal and accessfor service.Option: Provide foil faced insulation in lieu of standard.Foil insulation shall meet or exceed the requirementsstated above, and in addition meet ASTM StandardsC-665 and C-1136 for biological growth in insulation.Insulation shall be lined with aluminum foil, fiberglassscrim reinforcement, and 30 pound kraft paper laminatedtogether with a flame resistant adhesive. Allexposed edges shall be sealed to prevent any fibersfrom reaching the air stream.Option: Provide Elastomeric Closed Cell Foam Insulationin lieu of standard. Insulation shall conform to UL 181for erosion and NFPA 90A for fire, smoke and melting,and comply with a 25/50 Flame Spread and SmokeDeveloped Index per ASTM E-84 or UL 723. Additionally,insulation shall comply with Antimicrobial PerformanceRating of 0, no observed growth, per ASTM G-21.Polyethylene insulation is not acceptable.Unit mounting shall be by hanger brackets provided atfour locations. Hanger brackets shall include rubbergrommet isolators with brass eyelets for threaded rod.PAINTED FINISHAll painted cabinet exterior panels shall be finished witha heat cured anodic acrylic powder paint of the standardfactory color.SOUND<strong>Units</strong> shall have published sound power level datatested in accordance with ARI Standard 350-2000 (nonductedequipment) and ARI Standard 260-2001 (ductedequipment).FAN ASSEMBLYUnit fan shall be a dynamically balanced, forwardlycurved, DWDI centrifugal type constructed of 18 gaugezinc coated galvanized steel for corrosion resistance.Motors shall be high efficiency, permanently lubricatedsleeve bearing, permanent split-capacitor type with ULand CSA listed automatic reset thermal overload protectionand three separate horsepower taps. Single speedmotors are not acceptable.The fan assembly shall be easily removable for servicingthe motor and blower at, or away from the unit. Theentire fan assembly shall be able to come out of theunit by removing two screws and unplugging the motor.Plenum unit fan assemblies shall be easily servicedthrough an access panel provided.Option: Provide an electronic (SCR) fan speed controlleras an aid in balancing the fan capacity. The speedcontroller shall have a turn down stop to prevent thepossibility of harming the motor bearings, and incorporateelectrical noise suppression to minimize noise onthe incoming power lines.Option: Devices used to energize and de-energize(switch) fan speeds must be totally silent. Magnetic,mercury, and/or quiet relays and/or contactors are notacceptable.COILSAll cooling and heating <strong>coil</strong>s shall optimize rows andfins per inch to meet the specified capacity. Coils shallhave seamless copper tubes and shall be mechanicallyexpanded to provide an efficient, permanent bondbetween the tube and fin. Fins shall have high efficiencyaluminum surface optimized for heat transfer, airpressure drop and carryover.ENVIRO-TEC 19


Catalog: ET115.26-EG7 (908)GUIDE SPECIFICATIONS<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>All <strong>coil</strong>s shall be hydrostatically tested at 450 PSIG airpressure under water, and rated for a maximum of 300PSIG working pressure at 200°F.Direct expansion cooling <strong>coil</strong>s shall include a fixedorifice metering device. All evaporator <strong>coil</strong>s shall befactory sealed and charged with a minimum 5 PSIGnitrogen or refrigerated dry air.Steam <strong>coil</strong>s shall be standard steam type suitable fortemperatures above 35°F and 15 PSIG maximum workingpressure.Option: Coil casing shall be fabricated from StainlessSteel.All <strong>coil</strong>s shall be provided with a manual air vent fittingto allow for <strong>coil</strong> venting.Option: Provide automatic air vents in lieu of manualair vents.Heating <strong>coil</strong>s shall be furnished in the reheat or preheatposition on units with chilled water <strong>coil</strong>s, or in the reheatposition for DX <strong>coil</strong>s.DRAIN PANSPrimary condensate drain pans shall be single wall,heavy gauge galvanized steel for corrosion resistance,and extend under the entire cooling <strong>coil</strong>. Drain pansshall be of one-piece construction and be positivelysloped for condensate removal. Drain pans on concealedmodels shall be field reversible for right or lefthand connections.The drain pan shall be externally insulated with a fireretardant, closed cell foam insulation. The insulationshall carry no more than a 25/50 Flame Spread andSmoke Developed Rating per ASTM E-84 and UL 723and an Antimicrobial Performance Rating of 0, noobserved growth, per ASTM G-21.Option: Provide a single wall primary drain pan constructedentirely of heavy gauge stainless steel forsuperior corrosion resistance. Stainless steel drain pansshall be externally insulated and meet or exceed therequirements stated above.FILTERSAll plenum and exposed units shall be furnished with aminimum 1" nominal glass fiber throwaway filter. Filtersshall be tight fitting to prevent air bypass. Plenum unitfilters shall be easily removable from the bottom of theunit without the need for tools.Option: Provide unit with 1" pleated filter (MERV 6).ELECTRICAL<strong>Units</strong> shall be furnished with single point power connection.Provide an electrical junction box with terminal stripfor motor and other electrical terminations. The factorymounted terminal wiring strip consists of a multiple positionscrew terminal block to facilitate wiring terminationsfor the electric control valves and thermostats.Option: Provide a hinged electrical enclosure in thebottom of the unit for easy access to all electrical components,terminal blocks and wiring.ELECTRIC HEATFurnish an electric resistance heating assembly as anintegral part of the fan <strong>coil</strong> unit, with the heating capacity,voltage and kilowatts scheduled. The heaterassembly shall be designed and rated for installationon the fan <strong>coil</strong> unit without the use of duct extensionsor transitions, and be located in the unit as to notexpose the fan assembly to excessive leaving air temperaturesthat could affect motor performance.The heater and unit assembly shall be listed for zeroclearance and meet all NEC requirements, and be ETLlisted with the unit as an assembly in compliance withUL/ANSI Standard 1995.All heating elements shall be open <strong>coil</strong> type nichromewire mounted in ceramic insulators and located in aninsulated heavy gauge galvanized steel housing. Allelements shall terminate in a machine staked stainlesssteel terminal secured with stainless steel hardware forcorrosion resistance. The element support bracketsshall be spaced no greater than 3-1/2" on center. Allinternal wiring shall be rated for 105°C minimum.Option: Provide a secondary drain connection on theprimary drain pan for condensate overflow.20 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)GUIDE SPECIFICATIONSAll heaters shall include overtemperature protectionconsisting of an automatic reset primary thermal limitand back up secondary thermal limit. All heaters shallbe single stage.Option: Provide a manual reset secondary thermallimit.All units with electric heat shall have a bottom hingedelectrical enclosure for easy access and service to theelectrical components and wiring. An incoming linepower distribution block shall be provided and designatedto accept single point power wiring capable ofcarrying 125% of the calculated load current.Option: Devices used to energize and de-energize(switch) electric heat must be totally silent. Magnetic,mercury, and/or quiet relays and/or contactors are notacceptable.PIPING PACKAGESProvide a standard factory assembled valve pipingpackage to consist of a 2 or 3 way, on/off, motorizedelectric control valve and two ball isolation valves.Control valves are piped normally closed to the <strong>coil</strong>.Maximum entering water temperature on the controlvalve is 200°F, and maximum close-off pressure is 40PSIG (1/2") or 20 PSIG (3/4"). Maximum operatingpressure shall be 300 PSIG.Option: Provide 3-wire floating point modulating controlvalve (fail-in-place) in lieu of standard 2-position controlvalve with factory assembled valve piping package.Option: Provide high pressure close-off actuators for2-way on/off control valves. Maximum close-off pressureis 50 PSIG (1/2") or 25 PSIG (3/4)".Option: Provide either a fixed or adjustable flow controldevice for each piping package.Option: Provide pressure-temperature ports for eachpiping package.Piping package shall be completely factory assembled,including interconnecting pipe, and shipped separatefrom the unit for field installation on the <strong>coil</strong>, so as tominimize the risk of freight damage.ENVIRO-TEC 21


Catalog: ET115.26-EG7 (908)NOTES<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong>22 ENVIRO-TEC


<strong>HL</strong> <strong>Fan</strong>-Coil <strong>Units</strong> <strong>Low</strong>-<strong>Profile</strong>, <strong>Horizontal</strong> Catalog: ET115.26-EG7 (908)NOTESENVIRO-TEC 23


Printed on recycled paperCatalog: ET115.26-EG7 (908) Supersedes: Nothing© 2008 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USAwww.johnsoncontrols.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!