Why Draft Commander® 3000 A/T? - Weis Fire & Safety Equipment

Why Draft Commander® 3000 A/T? - Weis Fire & Safety Equipment

Why Draft Commander® 3000 A/T? - Weis Fire & Safety Equipment

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

‣ Two (2) 10 ft high pressure hoses for the UL vacuum and pressure plugs on theapparatus. One (1) end equipped with quick disconnects and the other end threadedswivel male to attach to the UL ports on the apparatus.‣ All gauges mounted in the monitoring station and labeled. A large 5 ½” wide by 13” tallsmooth board converter chart shall be etched on the face of the pump test station showingsize of tips, flow gallons per minute and PSI reading for each tip used.‣ One (1) etched fire pump test flow chart 20” wide X 18” high. Chart is to illustrate andgive instructions for pressure settings, pitot readings and equipment needed to perform aservice test on 500-2,500 GPM from draft. Located on front of monitor station.See example on page 12.Hose Storage Compartment and Misc. <strong>Equipment</strong>:‣ One large compartment 65” wide by 24” tall by 28” depth with V type bottom to storefire hose used for testing the fire apparatus. Large enough to store six (6) sections of 3”fire hose in 50 ft sections of coiled hose, spanner wrench, mallet, tools and etc.‣ Compartment to be ventilated and equipped with aluminum tread plate door withpneumatic openers, stainless steel hinges and stainless handles.‣ Compartment to be made of ⅛” aluminum treaded plate.‣ Each door to be equipped with chrome lift handlesSide Compartments:‣ Two heavy duty side compartments 40” wide by 6 ½” tall by 7” depth (one (1) each side)in front of fenders shall hold all flow tips.‣ Each nozzle tip to have individual compartments labeled with the size of tips.‣ Doors to be made of diamond plate aluminum with quick release hold downs.Additional Supplied <strong>Equipment</strong>:‣ Five 50 ft sections of 3” fire hose with 2 ½” couplings. Hose is 600# test and is doublejacket.‣ One 6” male by 5” female NST thread light weight adapter‣ One 6” male by 4 ½” ” female NST thread light weight adapter‣ One 6” male by 4” female NST thread light weight adapter‣ One 2 ½ male NST by 3” male NST thread light weight adapters‣ One 6” male by 2 ½” female NST thread light weight adapters‣ One 2 ½” double female adapter NST‣ One 2 ½” double male adapter NST‣ One heavy duty rubber mallet‣ One (1) UV rated vinyl net cover for top of open area of reservoir tank to keep reservoirclean. Cover to be white and to be net type material to remove air and heat fromreservoir with twist disconnects to hold down net and for ease of removal.‣ Two spanner wrenches and hydrant wrench with holder.Additional Requirements:‣ A list of 15 or more mobile pump testing unit users must be provided as per thesespecifications.‣ Operation and Training Manual along with a video will be provided upon delivery ofthe mobile pump testing unit.‣ The mobile pump testing unit has been in service and field tested for over five (5) years.‣ Descriptive information such as literature/brochures of these specifications to befurnished with bid.‣ Hands on personnel training and operations to be included.Page 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!