On-line Reid Vapor Pressure Analyzer forcontinuous measurement of hydrocarbon vaporpressures Measurement range of 0-35psi (0-2500 mbar) Superior repeatability of 0.05 psi (3.5 mbar) elevated sample temperatures of up to 75°C Rapid analysis cycle of 6 minutes or less Optional validation sample system Optional stream switching Remote diagnostics over IP Suitable for light crude oil applications

On-line Reid Vapor Pressure <strong>Analyzer</strong> forcontinuous measurement of hydrocarbon vaporpressures Measurement range of 0-35psi (0-2500 mbar) Superior repeatability of 0.05 psi (3.5 mbar) elevated sample temperatures of up to 75°C Rapid analysis cycle of 6 minutes or less Optional validation sample system Optional stream switching Remote diagnostics over IP Suitable for light crude oil applications


OPERATING PRINCIPLEThe P-<strong>700</strong>’s measurement cycle is based on the ASTM Methods D-323, D-4953and D-5482 and correlates to D-5191 and D-6377. This is done by using a digitallycontrolled syringe sample handling system, micro-volume solenoid valves and anangled measurement chamber equipped with a high-resolution pressure sensor andmagnetic stirrer.NONCOptionalMeasurementChamberPressureSensorCNONCCStirrer BarNONCCStream 1 INStream 1 OUTStream 2 INStream 2 OUTValidation/Grab SampleDigitalSyringeCell Purge DrainPurge Gas


To further enhance the precision and usefulness of the Model P-<strong>700</strong> <strong>RVP</strong> <strong>Analyzer</strong>, an optional validation/grab sample system can be added. This will allow the end user to either introduce a reference solution or aknown sample for immediate analysis. This feature provides a simple system verification or a quick analysisof a non-automated sample stream. The optional dual-stream sampling system offers an economic way ofautomatically monitoring two sample streams with a minimal loss of measurement response time.36 1 2 "927POWER IN(1/2 FNPT)SIGNALOUT(1/2 FNPT)CUSTOMERCONNECTION(1/2 FNPT)CUSTOMERCONNECTIONBOXAIR IN(1/4 FNPT)SAMPLE OUT(1/4 FNPT)SAMPLE IN(1/4 FNPT)ELECTRONICSENCLOSUREMAINPOWERSWITCH71"1803MEASUREMENTENCLOSURE30"762FREE STANDINGATMOSPHERICDRAIN(1/4 FNPT)22"559WALL MOUNT


PRODUCT GUIDEPetroleum <strong>Analyzer</strong>s•Flash Point•Salt in Crude•<strong>RVP</strong>•<strong>RVP</strong>/VL20•Cloud Point•Freeze Point•Pour Point•Viscosity•Viscosity IndexOther Products•UV-Oil in Water•Environmental Cabinets•3 Sided Shelters•Sample ConditioningSystems•Sample RecoverySystems•Spare Parts<strong>Analyzer</strong> Services•Field Service•Start-Ups•Training•Technical SupportANALYSIS PERFORMANCEMeasurement Cycle Time6 minutes or lessMeasurement Range0-35 psi, 0-175 kPa, 0-1.75 Bar (selectable)Repeatability± 0.05 psi (± 0.0035 bar)Reproducibility± 0.1 psi (± 0.007 bar)Resolution (Pressure Sensor)± 0.1 psi (± 0.007 bar)Accuracy Meets or Exceeds ASTM Methods D-323, D-4953, D-5482, & D-5191Temperature Accuracy± 0.1°C (± 0.2°F) of full scaleSAMPLE REQUIREMENTSSample Flow RateMin. 40 cc/min – Max. 100 cc/minSample Return PressureAtmospheric - 35 psi (2.4 Bar)Sample PressureMin. 20 psi (1.4 bar) – Max. 45 psi (3.1 bar) - optional sample conditioning systemavailable (P/N <strong>700</strong>538)Sample Temperature2°C (35 °F) - Max 40°C (105°F)Sample Particulates Less than 10 μm - optional sample conditioning system available (P/N <strong>700</strong>538)Sample ConditionsHomogenous, single-phase sample without water or water moistureENCLOSURE/INSTALLATION REQUIREMENTSDimensionsWidth 37.0 in (940mm) – Height 71.0 in (1803mm) – Depth 30.0 in (762mm)Weightapproximately 500 lbs (228 kg)Operating TemperatureMin. 40°F (5°C) – Max. 105°F (40°C)Enclosure Material Cast Aluminum Copper Free Alloy (Max Copper Content 0.3%)Area ClassificationSee Catalog Numbers BelowPowerJumper Selected 100 to 240 VAC (± 10%), 50/60 Hz, single phase, 2APurge AirClean, dry Instrument air at Min. 40 psi (2.7 bar) – Max. 100 psi (6.8 bar)Cabinet Cooling Purge Gas SupplyClean, dry Instrument air at Min. 80 psi (5.5 bar) – Max. 120 psi (8.2 bar)END USER CONNECTIONSAnalog Output SignalSingle isolated self powered 4-20 mA analog output (optional second output available),selectable for sample Flash Point values or temperature indicationRelay Output ContactThree SPDT relays with contacts rated at 3A resistive load at 250VAC, selectable forsample Flash Point alarm, analyzer maintenance warning or analyzer fault alarmSerial Input/Output SignalTCP/IP ModBus output availableHOW TO ORDERANALYZER SYSTEMSCatalog Number P-<strong>700</strong>-1400Catalog Number P-<strong>700</strong>-1500OPTIONSACCESSORIESCatalog Number <strong>700</strong>228Catalog Number <strong>700</strong>538Catalog Number <strong>700</strong>175Catalog Number <strong>700</strong>176ORB Model P-<strong>700</strong> <strong>RVP</strong> <strong>Analyzer</strong>, CSA-CUS Ex d Class I Division 1 Groups B, C, DORB Model P-<strong>700</strong> <strong>RVP</strong> <strong>Analyzer</strong>, ATEX Ex d IIB + H2 T6 GbSample Recovery System(low pressure and high pressure, contact ORB for further details)Sample Conditioning Panel (for sample pressures greater than 35 psiand sample particulates greater than 10μm)1-Year Spare Parts Kit2-Year Spare Parts KitLit. No. P-<strong>700</strong>-EN-US / AUG120518 II 2 GXPROOFatex/ceXPROOFCSA/CUSPURGEDatex/cepurgedulcsa/csaGENERALPURPOSEORB Instruments, Inc.4724 South ChristianaChicago, IL 60632 / USAPhone: + (1) 773 927-8600Fax: + (1) 773 927-8620Email: sales@orbinstruments.<strong>com</strong>www.orbinstruments.<strong>com</strong>