12.07.2015 Views

Solutions for tunnels - OBO Bettermann

Solutions for tunnels - OBO Bettermann

Solutions for tunnels - OBO Bettermann

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BSK fire protection duct <strong>for</strong> direct wall and ceiling mountingBSK fire protection duct I 90/E 30, internal height 50 mmCable routingTypeDimensionBDimensionHDimensionhDimensionbLengthWeightmm mm mm mm mmkg/100 mBSK 090506 120 95 50 60 1000 730.000 7215 15 0BSK 090511 170 95 50 110 1000 940.000 7215 15 4BSK 090521 270 95 50 210 1000 1350.000 7215 15 8Fire protection duct I90/I30, to DIN 4102 Part 11 and Part 12, incl. 12 x countersunk headscrews and 3 x 1 m sealing strip.BSK end piece I 90/E 30 <strong>for</strong> internal height 50 mmTypeDimensionBDimensionHEnd piece <strong>for</strong> fire protection duct BSK I90/E30Including bolts and sealing strip.WeightItem No.mm mmpcs kg/100 pcs.BSK-E090506 120 95 1 38.000 7215 25 0BSK-E090511 170 95 1 51.000 7215 25 2BSK-E090521 270 95 1 78.000 7215 25 4/pc.Pack./mItem No.BSK wall connection collar I 90 <strong>for</strong> internal height 50 mmTypePack.WeightItem No.pcs kg/100 pcs.BSK-K05061 40.000 7215 53 3BSK-K0511 1 45.000 7215 53 7BSK-K0521 1 55.000 7215 54 1/pc.Wall connection collar <strong>for</strong> BSK, consisting of three single plates, to double the insulation <strong>for</strong> wallpenetrations. Incl. fastening material Only <strong>for</strong> I90 classification.BSK fire protection duct I 90/E 30, internal height 105 mmTypeDimensionBDimensionHDimensionhDimensionbLengthWeightmm mm mm mm mmkg/100 mBSK 091016 220 150 105 220 1000 1430.000 7215 16 2BSK 091026 320 150 105 260 1000 1830.000 7215 16 6/mFire protection duct I90/I30, to DIN 4102 Part 11 and Part 12, incl. 12 x countersunk headscrews and 3 x 1 m sealing strip.BSK end piece I 90/E 30 <strong>for</strong> internal height 105 mmTypeDimensionBDimensionHEnd piece <strong>for</strong> fire protection duct BSK I90/E30Including bolts and sealing strip.WeightItem No.Item No.mm mmpcs kg/100 pcs.BSK-E091016 220 150 1 93.000 7215 25 6BSK-E091026 320 150 1 131.000 7215 25 8/pc.Pack.BSK wall connection collar I 90 <strong>for</strong> internal height 105 mmTypeWeightItem No.pcs kg/100 pcs.BSK-K10161 65.000 7215 54 5BSK-K1026 1 75.000 7215 54 9/pc.Wall connection collar <strong>for</strong> BSK, consisting of three single plates, to double the insulation <strong>for</strong> wallpenetrations. Incl. fastening material Only <strong>for</strong> I90 classification.Pack.12 LTB Lösungskatalog Tunnelbau / en / 06/04/2010 (LLExport_01022)34 <strong>OBO</strong> LTBAlways indicate the article number when ordering.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!