Sunblind (FbSunblind)Sunblind functionsSunblind (FbSunblind)WAGO-I/O-PRO CAA Library ElementsCategory:Building AutomationName:FbSunblindType: Function Function block X ProgramLibrary Name:Building_common.libApplicable to:All programmable fieldbus controllersInput Parameter: Data type: Comment:xSunblindSwitchUp BOOL Switch command Sunblind UPxSunblindSwitchDown BOOL Switch command Sunblind DOWNxMoveToShadowPosition BOOL Move to shadow positionxSafety BOOL Signal input: safety positionxManualAutomatic BOOL Switch-over Manual/AutomaticuiT_WholePosTimeIn10telSecuiT_WaittimeUpDownIn10telSecUINTUINTMotor running timeValue range: 0 – 3000 [0.1s]Default setting = 700Pause when changing directionValue range: 6 – 30 [0.1s]Default setting = 7uiT_SwitchShortIn10telSec UINT Time for brief key actuationDefault setting = 5uiT_MoveShadowPosIn10telSecUINTMotor running time DOWN for shadowpositionValue range: 0 – 3000 [0.1s]Default setting = 300uiT_MoveShortIn10telSec UINT Sunblind setting time via switchcommandDefault setting = 2uiT_MoveTurnLamellaIn10telSecUINTSunblind setting time, automaticValue range: 0 – 30 [0.1s]Default setting = 4xTurnAutomatic BOOL Turn automatic ON / OFFDefault setting = FALSEFeedback Value: Data type: Comment:xDoSunblindUp BOOL Actuator command, sunblind UPxDoSunblindDown BOOL Actuator command, sunblind DOWNbPos_0_200 BYTE Return information of the sunblindposition0 = sunblind up200 = sunblind downSubject to design changes WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D-32385 Minden Tel.: 05 71 / 8 87-0 E-Mail: info@wago.comCopyright © 2009 Hansastr. 27 • D-32423 Minden Fax.: 05 71 / 8 87-169 Web:http://www.wago.com8

Sunblind (FbSunblind)Sunblind functionsSunblind (FbSunblind)WAGO-I/O-PRO CAA <strong>Library</strong> ElementsCategory:<strong>Building</strong> <strong>Automation</strong>Name:FbSunblindType: <strong>Function</strong> <strong>Function</strong> block X Program<strong>Library</strong> Name:<strong>Building</strong>_common.libApplicable to:All programmable fieldbus controllersInput Parameter: Data type: Comment:xSunblindSwitchUp BOOL Switch command Sunblind UPxSunblindSwitchDown BOOL Switch command Sunblind DOWNxMoveToShadowPosition BOOL Move to shadow positionxSafety BOOL Signal input: safety positionxManualAutomatic BOOL Switch-over Manual/AutomaticuiT_WholePosTimeIn10telSecuiT_WaittimeUpDownIn10telSecUINTUINTMotor running timeValue range: 0 – 3000 [0.1s]Default setting = 700Pause when changing directionValue range: 6 – 30 [0.1s]Default setting = 7uiT_SwitchShortIn10telSec UINT Time <strong>for</strong> brief key actuationDefault setting = 5uiT_MoveShadowPosIn10telSecUINTMotor running time DOWN <strong>for</strong> shadowpositionValue range: 0 – 3000 [0.1s]Default setting = 300uiT_MoveShortIn10telSec UINT Sunblind setting time via switchcommandDefault setting = 2uiT_MoveTurnLamellaIn10telSecUINTSunblind setting time, automaticValue range: 0 – 30 [0.1s]Default setting = 4xTurnAutomatic BOOL Turn automatic ON / OFFDefault setting = FALSEFeedback Value: Data type: Comment:xDoSunblindUp BOOL Actuator command, sunblind UPxDoSunblindDown BOOL Actuator command, sunblind DOWNbPos_0_200 BYTE Return in<strong>for</strong>mation of the sunblindposition0 = sunblind up200 = sunblind downSubject to design changes WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D-32385 Minden Tel.: 05 71 / 8 87-0 E-Mail: info@wago.comCopyright © 2009 Hansastr. 27 • D-32423 Minden Fax.: 05 71 / 8 87-169 Web:http://www.wago.com8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!