12.07.2015 Views

FW Murphy 2008 - Howard Instruments

FW Murphy 2008 - Howard Instruments

FW Murphy 2008 - Howard Instruments

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>FW</strong> <strong>Murphy</strong> <strong>2008</strong>CONDENSED CATALOG


Reliable.Innovative.Customer Focused.


MURPHY PRODUCTSFor more than 65 years, people and companiesaround the world have depended on <strong>Murphy</strong>for monitoring and protection of their engines anddriven equipment.Our product line covers instruments thatmonitor critical functions of your equipment.We have J1939/CAN instrumentation,compressor controls, custom panels,auto start/stop controllers, sensors and more.


INDEXINTRODUCTION1WORLD MAP2INDEX3GAGES4 - 8DISPLAYS8 - 9ENGINE CONTROLS10 - 11PANELS AND SYSTEMS12 - 15COMPRESSOR CONTROLS16 - 17PROCESS MONITORING INSTRUMENTS18 - 21


GAGES<strong>Murphy</strong> is known for its gages, and there’s a good reason why.They’re durable and dependable. They’re highly accurate andlong-lasting. We didn’t make them so popular – our customersdid. We just make them solid and reliable every time.Mechanical Pressure Swichgage ®and <strong>Murphy</strong>gage ® <strong>Instruments</strong>(Catalog Section 05)Featured Product: 20P Gage●●●●●Classic Swichgage designCombination indicating pressure gage and limit switchPressure limit switch visible and adjustableSwitch can activate alarms and/orshutdown equipmentExceeds SAE StandardsMost of these products have standard normally open switch outputs.pressuredifferentialpressurevacuumhazardousrated*20P/25P • • • • •A20P/A25P • • • • • •20V/A20V/25V/A25V • • • •2"2.5"4.5"51mm 64mm 114mmNO/NCsystems*diaphragm(90˚ sweep)bourdon tube(270˚sweep)20DP/A20DP/25DP/A25DP • • • • • •20VWC/25VWC/A25VWC • • • •20BPG** • • •OPL-series • • • • •OPL-BP-series • • • • •45APE • • • • • •PT167EX • • • •*Specific models only**No contacts4 CONDENSED CATALOG <strong>2008</strong>


GAGESMechanical TemperatureSwichgage ® andGage <strong>Instruments</strong> (Catalog Section 10)Featured Product: A20T gage●●●●●Corrosion-resistant polycarbonate caseIndicating temperature gage and limit switchSwitch can activate alarms and/or shutdownequipmentContact(s) isolated from groundStandard normally open switch outputsmetal casepolycarbonatecasedirectmount2"51mm2.5"64mm4.5"114mmhazardousrated*NO/NCsystems*diaphragm(90˚sweep)bourdon tube(270˚sweep)bimetal20T/25T • • • • •A20T/A25T • • • • • •SPL-series • • • •20BTG** • • •45TE-series • • • • •SDB-series • • • •*Specific models only**No contactsADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 5


GAGES continuedElectric Swichgage ®and Gage <strong>Instruments</strong> and Senders(Catalog Section 70)Featured Product:EGS21P Electric Swichgage●●●●EG Air Core movement designRugged design exceeds SAE J1810 standardsAdjustable set pointSolid-state switch outputOther EG Products:● CANDrive – J1939 to electric gage convertorgage sender pressure temperature fuel level voltage andcurrentswitchingweathersealedEG21-series • • • • • •EGS21-series • • • • • • •ESP-series • • n/aEST-series • • n/aESF-series • • n/a6 CONDENSED CATALOG <strong>2008</strong>


GAGES continuedHourmeters and Tachometers(Catalog Section 20)Featured Product: ATHATachometer/Hourmeter●●●●Sensing from magnetic sensor signal orbattery charging alternatorHigh visibility analog readoutAir core movementEasy calibration through dial lightingtachometer hourmeter digital analog mag pickup alternatorbatteryvoltage electromechanicalignitionbacklightMT90 • • • • •MTH6 • • • • • •TM-series • • •AT-series • • • • • • •EGT/H-series • • • • • • •ADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 7


GAGES continuedDISPLAYSPowerView Analog Gages(Catalog Section 78)Featured Product:PVM20-T Temperature Gage●●●●●●Displays J1939 parameters in an analog gageSmooth needle movement270° sweep pointerWide selection of lens and bezel styles and colorsAdjustable LED backlightingPV101 drives the PVM gages, they can also be drivenby other products when using the PVS-5 power supplyCommon parameters include: pressure, temperature, time, speed, volts and fuel.Power Supplyinput voltage2”51mm3.5”89mmDisplaysJ1939 DataDriven byPV101PVA gage 6 - 32 • • • • •PVAA gage 8 - 32 • • • •PVM gage 5 • • • • •RS485 J1939 AudiblealarmJ1939/CAN PowerView (Catalog Section 78)DisplaysFeatured Product: PV101 Display●●●Displays SAE J1939 standard and proprietary messagesWide operating temperature range (-40 to 185°F/85°C).Displays SAE J1939 diagnostic trouble codes withtext translations for diagnosing most commonequipment malfunctions8 CONDENSED CATALOG <strong>2008</strong>


Electronic engines are a mystery to most people. Not to <strong>Murphy</strong>.We’ve cracked the code of the modern ECU to give operators aclear view of what their engines are doing at any time. Ourdisplays use cutting-edge technology, without sacrificing durabilityDISPLAYSJ1939/CAN PowerView (Catalog Section 78)DisplaysFeatured Product:PV1000 Display●●●●●<strong>Murphy</strong>’s flagship J1939 displayLarge full-color VGA screenFull integration within a single displayGPS display capabilities built-inRemote keypad option availablePower Supply Display CAN ports optionalGPS displayscreen size(diagonal)PV101 12/24 B/W LCD 1 4” (102mm)PV1000 12/24 Color VGA 4 • 6.5” (165mm)Other J1939 Products:● XM500 – CAN i/o module● CANdrive - Interface to drive electric gages● SenderCAN - Analog Input to CAN● FuelCAN - Fuel Sender to CANADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 9


ENGINE CONTROLSEngine Controllers (Catalog Section 40)Featured Product: Cascade CD101Auto-Start/Stop Controller●●●Automatic start and stop control with easy configurationDesigned for both mechanical and electronically controlled enginesJ1939 Ready – works directly with <strong>Murphy</strong>Link TM PVA gagesAdditional options are available. Call <strong>Murphy</strong> for advice on your specific applications.autostart/stopdigital display LEDindicatormechanicalenginessupportelectronicengines support(J1939)EMS-series • • • • •eGuard • • • • • •Cascade CD101 • • • • • • •ASM-series • • • • •A91 • • • • •basicconfigurableOther Engine Controls:● Keystart – manual start/stop and automatic fault protectionTattletale ® Annunciators and Magnetic Switch Relays(Catalog Section 25)Featured Product: Tattletale Annunciators●●●Translates Swichgage contact operations into decisions to operate alarms or shutdown devicesShows which monitored function caused an alarm or shutdownWeather resistant caseannunciator mag switch 12/24 VDC 120 VAC CD ignition electricallatch117-series • • • •518-series • • • •MS-series • • • • • •mechanicallatch10 CONDENSED CATALOG <strong>2008</strong>


ENGINE CONTROLSFeatured Product: RP75 Rack Puller for Diesel Engines●●●●Electro-Mechanical Controls(Catalog Section 40)Pulls injection pump or air intake shut-off lever30 lbf operating forceAvailable for 12- or 24-volt systemsOperates on signal from Swichgage instrumentsthrottle clutch rack puller ETR ETS Omnivoltage12 VDC 24 VDCAT03069 • • • •CO3 • • •RP75 • • • •RP2307-RP2310 • • • •Battery Chargers (Catalog Section 75)Featured Product: Guardian Battery Charger●●●●High-quality constructionControlled charge currentsAuto boostTemperature compensationFloatChargingAutoboostTemperaturecompensationMaximumcurrent ADCNominalvoltage VDCCharge fallrelay outputSentry • • • 5A at 12v 12 •Guardian • • • 10A at 12/24VDC 12/24 •20A at 24 VDCADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 11


PANELS ANDSYSTEMS<strong>Murphy</strong> has spent years cultivating its expertise in electronicengines and ECUs. Now we're delivering our knowledge directlyto you. We have a staff of application engineers dedicated tobuilding just the right panel for your application. From customprogramming and configuration to equipment dashes andcustom displays -- if you can imagine it, we can build it.Panel Systems for Electronically-Controlled Engines (Catalog Section 30)Featured Product: M-Series <strong>Murphy</strong>Link TM Panel●●●●●Standard panel for modern electronic enginesCombines analog gages with the award-winning PowerView 101 displayStandard wiring harnesses available for most manufacturer’s ECUsDeutsch connectors for easy installationOptional controllers available for engine automationPanels for Deutz 1011/2011, 912/913, and 914 EnginesmechanicalengineselectronicenginesdigitaldisplayanaloggagesautostartI/OWDU 500 series • • Cascade 4/4WDU 600 series • • PV101 Tach Cascade 4/4WDU 800 series • EG and TachPanels for Pump Control / Power UnitsmechanicalengineselectronicenginesdigitaldisplayanaloggagesautostartThrottleto InputI/OM110-series • PV101M320-series • PV101 PVAM520-series • • Cascade 4/4M620-series • • PVA Cascade 4/4M720-series • • eGuard PVA eGuard • 32/812 CONDENSED CATALOG <strong>2008</strong>


PANELS ANDSYSTEMSPanel Systems for Mechanically-Controlled Engines (Catalog Section 30)Featured Product: MC100 Panel●●●Configurable panel – standard panel sizes that can be configuredwith multiple optionsChoose your gages, starting method, tachometer, mountingoptions – even add a hinged door or hinged faceplateCustomize your panel online. Get it shipped within a weekApplicationsMC10075160/WHBEA150WD300WDU-277Online Quote/Spec Capability - General ShutdownShutdown for Irrigation AppsBasic Micro ControllerIncludes SV Series Fuel Shut-off valveDeutz 413, 511, 912 and 913 EnginesPanel Systems for Generator Sets(Catalog Section 30)Featured Product: MGC150 Panel●●●Cascade/eGuard controller optionsProvision for optional PVA gages or PowerViewQuick disconnect and standard MEH harness availablemechanicalengineselectronicenginesmetering (voltsamps hertz)digitaldisplayanalog gages autostart I/O applicationsMGC25 • • • Power Gen. - Meter onlyMGC50 • • Pwr Gen.- w/KeyswitchMGC100 • • • PVA/M or EG • Power Gen. - CascadeMGC150 • • • PV101 • Power Gen. - CascadeMGC300 • • included w/iGuardincluded w/iGuard• 32/8 Power Gen. - iGuardMGC350 • • included w/iGuardincluded w/iGuard• 52/28 Power Gen. - iGuardADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 13


PANELS ANDSYSTEMSPanel Systems for BasicShutdown (Catalog Section 50)<strong>Murphy</strong>’s Control Systems and Services offers a full line ofcontrol panels. We offer controls and interfaces for a widerange of applications — from engines and motors, to pumpsand compressors. We start with a basic platform, then addyour custom design. Instrumentation, layout, software — youget it exactly how you want it. It’s the total <strong>Murphy</strong> treatment —reliable control backed by full customer service.Basic Shutdown Panel Featuring The TTD TM Controller●●Fully-configurable fault annunciatorIncludes alarm and shutdown controlcommunications I/O configurableI/Onon-incendiveinputsintrinsicallysafe inputsareaclassificationTTD RS232/RS485* 48/4 • csa cl. I, div. 2NO/NCgrps. B, C, DLCDT 47/3 • • csa cl. I, div. 1NO/NCgroup D*Communication ports utilized for operation visibilityPanel Systems for Low PressureWellhead Control (Catalog Section 50)Basic Autostart Control PanelFeaturing The WellPro TM Controller●●Fully-configurable fault annunciatorIncludes alarm and shutdown controlcommunicationsconfigurableI/Onon-incendiveinputsintrinsicallysafe inputsareaclassificationWellPro RS485, USB* 17/8 • •** csa cl. I, div. 2NO/NCgrps. B, C, D*Communication ports utilized for operation visibility and control.**Available with use of external barriers.Control Systems and Services features weather-proof enclosures with safety glass windowspainted to specifications or stainless steel, vibration/shock mounted subpanel inserts andtemperature-controlled solutions when required.UL and/or CSA approvals for control panels available. Additional area approvals available.CS&S is a certified UL and CSA manufacturing facility.14 CONDENSED CATALOG <strong>2008</strong>


PANELS ANDSYSTEMSPanels Systems for Basic Shutdownand Autostart (Catalog Section 50)Basic Shutdown/Autostart PanelFeaturing The Centurion TM Controller●●A hybrid of annunciator and compressor controllerCombines the monitoring and shutdown features of an annunciator,with auto-start and basic engine controls that help prevent shutdowncommunications I/O configurableI/Onon-incendiveinputsintrinsicallysafe inputsareaclassificationCenturion RS232/RS485 53/12USB* NO/NC16/4 • •** csa cl. I, div. 2grps. B, C, DS1501 RS232/RS485 64/7 • • csa cl. I, div. 1NO/NCgrps. C & D*Communication ports utilized for operation visibility and control**Available with use of external barriersPanels Systems for Full-FeaturedControl (Catalog Section 50)Full-Featured Control Panel FeaturingThe Millennium TM Controller●●Full-featured monitoring, control and data acquisition systemHighest-end controller availablecommunicationscomplex configurable configurablecalculations I/O I/O expansionnon-incendiveinputsintrinsicallysafe inputsareaclassificationMillennium RS232 • 17/10 74/12** • •*** csa cl. I, div. 2RS485*NO/NCgrps. B, C, D3rd Party user • user defined user defined • •*** csa cl. I, div. 2PLC defined*grps. C & D*Communication ports utilized for operation visibility and control**I/O can be of any configuration of five (5) expansion modules***Available with use of external barriersADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 15


COMPRESSORCONTROLSBasic shutdown? Temperature scanning? Total control?Whatever level of control you need, <strong>Murphy</strong> has you covered.Don’t pay extra, and don’t settle for too little. Find a controllerwith the right mix of features for you.Annunciators(Catalog Section 50)Featured Product: TTD TM Annunciator●●●●Digital annunciator with shutdown capabilitiesMonitors up to 48 user-configurable sensor inputsCommunications ports includedAdditional options available, such as tachometer,pre/post lube, and lube no-flow detectionDCpowerignitionpowerACpowerDiv. 1classificationDiv. 2classificationinternaltachometerhourmeterNO/NCinputsTTD • • • • • 48LCDT • • • • 47/45S1501 • • • • • 26/6416 CONDENSED CATALOG <strong>2008</strong>


COMPRESSORCONTROLSControllers(Catalog Section 50)Featured Product: Centurion TM Controller●●●Fully-configurable control and monitoring systemExpandable to meet most 3-stage compressor applicationsNo programming experience required. Off-the-shelf programminghandles the most commonly used control sequencesanaloginputsthermocoupleinputsanalogoutputsdigitalinputsdigitaloutputsexpandability expansion I/O communicationportsUSBdisplayCenturion 12 8 2 (optional) 32 10 1 module 8 AI + 8 TC 2 RS485/+ 4 AO RS232 + USB• graphic LCDMillennium by expansion by expansion 2 16 8 5 modules varies by module, 4 RS485 +up to 5 modules 2 RS232character VFDTemperature Scanners(Catalog Section 10)Featured Product: TDXMTemperature Scanner●●●Scans up to 24 channelsThree adjustable trip points per channelAccepts any combination of J- or K- typegrounded or ungrounded thermocouplespointsdigitaldisplaycommunications(RS485)DC powerignitionpowerAC powerTDXM 24 • • • 3TDX6 6 • • • • 6MDTM89 2 • • • • 2outputsADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 17


PROCESS MONITORINGINSTRUMENTSDo you have a function of your equipment that needs monitoring orcontrolling? That’s what you’ll find here. Get clear information on thehealth of your equipment, and protect it through automatic monitoring.Vibration Switches and Controls(Catalog section 20)Featured Product: EVS TM – Electronic Vibration Switch●●●●●Electronically integrated output signal trips on velocity-based vibrationAdjustable calibrated set-point controlsAccelerometer-based for accuracy and durabilityOptional 4-20 mA output for continuous monitoring capabilityAvailable for class 1, div.1 or 2, grps. c & d hazardous areasVS2•VS2EX • •EVS • • • •CSS-series • •VS94•*specific models onlyVibrationswitchmonitor4-20 mAoutputhazardousrated*Level Maintainers and Level Switches(Catalog section 15)Featured Product: LM2000 Lube Level Maintainer●●●Automatically maintains lube levelDisplays oil level and condition without shutting downPositive sealing Thumb-Valve Operationmaintainer sight glass gage hazardousrated*LM2000 • •LM300-series • • •L150•EL150-series • •L129L100-series••OPLH-series • •*specific models only18 CONDENSED CATALOG <strong>2008</strong>


PROCESS MONITORINGINSTRUMENTSScrubber Level Controls (Catalog section 15)Featured Product: LS200 Liquid Level Switch●●●●●304 stainless steel float operates in 0.5 specificgravity and heavier fluidsRated for 2000 psi (13.8 MPa) [138 bar] working pressureElectric and pneumatic models availableImproved snap actionScrews directly into the vessel or mounts via externalfloat chamberpneumatic electric SPDT DPDT inlet pipe hazardousoption size rated*LS200 • • • 2 NPT •LS200N • 2 NPT • • •L1100 • • • 1.5 NPT •DVOpilot valveL1100N • 1.5 NPT • • •*specific models onlyDVORw/filterregulatorValves (Catalog section 15/55)Featured Product: DVU Series Dump Valve●●●For Separators/Scrubbers to 2000 psiHex union allows plug and seat replacement withoutpiping removalOperates on 30-70 psi control pressureinlet pipe size outlet pipe size max. working pressure150-series* 1 NPT 1/2 NPT 1800 psi175-series* 1 NPT 3/4 NPT 1800 psi2100-series 2 NPT 1 NPT 500-2000 psi*316 stainless steel model available.ADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 19


PROCESS MONITORINGINSTRUMENTS continuedFuel Valves (Catalog section 55)Featured Product: M50 SeriesFuel Shutoff Valve●●●Instant response to shut off signalPositive valve closureVents gases trapped after shutdownshutoff valve check valve pressurerelief valveenergizeto openapplicationsSV-series • • dieselCKV • dieselPRV • dieselM25 • natural gasM50 • natural gasPressure and Temperature Sensors(Catalog section 5/10)Featured Product: PXT Series Pressure Transmitters●●●●●0.25% accuracy4-20 mA output signalPrecision etched silicon sensorCorrosion resistant constructionHigh stabilitypressure temperature SPDT switch transmitter direct mountPSB • • (factory set) • •TSB • • (factory set) • •PXT • •20 CONDENSED CATALOG <strong>2008</strong>


PROCESS MONITORINGINSTRUMENTS continuedTemperature Sensors(Catalog section 10)Featured Product: ThermocoupleEncased in 1/4” Stainless Steel●●●●316 braided shield with Teflon overlay extension wireK type, 6” and 10” long 1/4” probesCan be bent anywhere along its length to a 90° angleTip sensitive to minimize temperature influence fromsurrounding environmentsensor transmitter direct mount conduit head outputTC-series J/K • • mv1/4” Thermocouple K • mvRTD 100 Ohm, • • 100 Ohm,platinum3 wireRTDT 100 Ohm, • •platinum 4-20 mA4-20 mASpeed Measurement and Switches(Catalog section 20)Featured Product: SHD30 Tach/Hourmeter●●●Digital tachometer hourmeter with overspeed trip pointNormally open and normally closed overspeed alarm and shutdownApproved for class I, division 2 gps. c & d hazardous areasspeed sensor speed switchadjustablesetpoint output SPDT mag Pickup CD ignition alternatorMP (Mag Pickup) • pulsed •SS300 series • 1 relay • • •OS77 series • 1 transistor • •HD9063 series • 2 relay • •SHD30 • 1 solid state/ • • •relayADDITIONAL MODELS AVAILABLE. SEE FULL CATALOG FOR MORE DETAILS. 21


<strong>FW</strong> <strong>Murphy</strong>P.O. Box 470248Tulsa, Oklahoma 74147 USAPhone: 918.317.4100 Fax: 918.317.4266E-mail: sales@fwmurphy.comWeb site: www.fwmurphy.comIndustrial Panel Division**P.O. Box 470248Tulsa, Oklahoma 74147 USAPhone: 918.317.4100 Fax: 918.317.4124E-mail: ipdsales@fwmurphy.comWeb site: www.fwmurphy.com/ipdControl Systems &Services Division*P.O. Box 1819Rosenberg, Texas 77471 USAPhone: 281.633.4500 Fax: 281.633.4588E-mail: sales@fwmurphy.comWeb site: www.fwmurphy.com*Oil & Gas Markets: Field Gas Gathering,Gas Transmission, Gas Power Generation**Industrial Markets: Industrial Stationary,Off Highway, Marine, Power GenerationFrank W. <strong>Murphy</strong>, LTDSwichgage House, Church RdLaverstock Salisbury, SP1 1QZUnited KingdomPhone: +44 1722 410055 Fax: +44 1722 410088E-mail: sales@fwmurphy.co.ukWeb site: www.fwmurphy.co.ukComputronic Controls LTD.41 – 43 Railway TerranceNechells Birmingham, B7 5NGUnited KingdomPhone: +44 (0) 121 327 8500 Fax: +44 (0) 121 327 8501E-mail: info@computroniccontrols.com<strong>FW</strong> <strong>Murphy</strong> <strong>Instruments</strong>(Hangzhou) Co. LTD.77 23rd StreetHangzhou Economic & Technological Development AreaHangzhou, Zhejiang 310018, ChinaPhone: +86 571 8788 6060 Fax: +86 571 8684 8878Frank W. <strong>Murphy</strong> International Trading(Shanghai) Co., LTD.Suite 1784, Tower B, City Center of Shanghai; 100 Zunyi RoadShanghai, 200051, ChinaPhone: +86 21 6237 2082 Fax: +86 21 6237 2083E-mail: mhong@fwmurphy.com<strong>2008</strong>REGISTEREDDistributed by:In order to consistently bring you the highest quality,full featured products, we reserve the right tochange our specifications and designs at any time.Specifications and performance data subject tochange without notice. Certified specifications andperformance data available upon request.All trade marks and service marks used in this documentare the property of their respective owners.0710221-Cond. 4/08 Printed in USAwww.fwmurphy.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!