12.07.2015 Views

7130 Oil Burner Controls LMO14... LMO24... LMO44... - Romstal

7130 Oil Burner Controls LMO14... LMO24... LMO44... - Romstal

7130 Oil Burner Controls LMO14... LMO24... LMO44... - Romstal

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Commissioning notes• When commissioning the plant or when doing maintenance work, make the followingsafety checks:Safety checka) <strong>Burner</strong> startup with flame detector darkenedb) <strong>Burner</strong> startup with flame detector exposedto extraneous lightc) <strong>Burner</strong> operation with simulated loss offlame; for that purpose, darken the flamedetector during operation and maintainthat stateAnticipated responseLockout at the end of «TSA»Lockout after no more than 40secondsRepetition followed by lockout atthe end of «TSA»Standards and certificatesConformity to EEC directives- Electromagnetic compatibility EMC (immunity)- Low-voltage directive2004/108/EC2006/95/ECISO 9001: 2000Cert. 00739ISO 14001: 2004Cert. 38233Type Identification code to EN 230:<strong>LMO14.</strong>..F M L L X N<strong>LMO24.</strong>..F M L L X N<strong>LMO44.</strong>..F M L L X N to WLEService notes• Use the KF8885 / KF8833 / KF8840 service adapters for short periods of time onlyLife cycle<strong>Burner</strong> controls has a designed lifetime* of 250,000 burner startup cycles which, undernormal operating conditions in heating mode, correspond to approx. 10 years of usage(starting from the production date given on the type field). This lifetime is based on theendurance tests specified in standard EN230 and the table containing the relevant testdocumentation as published by the European Association of Component Manufacturers(Afecor) (www.afecor.org).The designed lifetime is based on use of the burner controls according to the manufacturer’sData Sheet. After reaching the designed lifetime in terms of the number ofburner startup cycles, or the respective time of usage, the burner control is to be replacedby authorized personnel.* The designed lifetime is not the warranty time specified in the Terms of DeliveryDisposal notesThe unit contains electrical and electronic components and must not be disposed of togetherwith domestic waste.Local and currently valid legislation must be observed.3/13Building TechnologiesCC1N<strong>7130</strong>enHVAC Products 15.09.2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!