12.07.2015 Views

Catalogue angl PART A.pdf - FCE

Catalogue angl PART A.pdf - FCE

Catalogue angl PART A.pdf - FCE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

WELLTESTING EQUIPMENT FLOWHEADS16DESCRIPTIONThe flowhead is used as a temporary wellhead on a drillingrig. <strong>FCE</strong> offers a compact light weight unitized flowheadfitted with:- 2 1/16 ” kill wing gate valve & a 2” Fig.1502F connection.- 3 1/16 ” flow wing gate valve & a 3” Fig.1502M connection.- 3” upper and lower Kelly valves.- 400 000 lbs Swivel allowing the test string to rotate.- 4 ½ ” IF bottom sub connection c/w test cap.- 5¾” - 4 Otis ACME box lift sub top connection c/w pin andcollar test cap.The flowhead is supplied with it’s own lift sub and can beunitised with it’s own transport skid.The flow wing gate valve is fitted with a hydraulic actuatorand can be used as an ESD valve.OPTIONS- 250 000 lbs Swivel.- Low temperature service (up to -40°C).- High temperature service (up to +190°C).- Other top and bottom connections on request.- “Stiff” Joint- Check valve on kill wing.- Specific inspection level on customer request.(PSL3, PED certification & CE marking, etc.).- DNV 2.7.3 or 2.7.1 certified skid.PROCESS & DESIGN DATAAPI 6A / NACE MR 01-75 for sour gasDesign pressure ......................................... : 10 000 PSI.Design temperature ................................. : -29°C to 121°C.Wing valve hyd. operating pressure ....... : 6000 PSI max.Inspection level ......................................... : PSL2.WEIGHTS & DIMENSIONS (with transport skid)Length in mm 5000Width in mm 1500Height in mm 1600Weight in kg 2500WELLTESTING EQUIPMENTESDV’S & CONTROL SYSTEMSDESCRIPTIONEmergency ShutDown Valves (ESDV) for well testingapplications are generally reverse acting gate valvesequipped with a hydraulic linear actuator (occasionallypneumatic) and complete with the required x-overs. Inoffshore applications this valve may be incorporated intoa flowhead, but for land use, it is normally skid mountedand installed close to the wellhead. Actuators are fail close,usually single acting with hydraulic pressure to open andspring assist to close upon the loss of hydraulic pressure.The ESD Panel, in its more basic form, consists of a smallhydraulic oil tank, an air driven hydraulic pump providingopening pressure via a hose to the ESDV and a hydrauliccircuit to permit ”push button” ESDV closure.The panel will receive its ”process” signal from upstream highor low pressure switches (or pilots) or from additional inputs.PROCESS & DESIGN DATAAPI6A and NACE MR01-75 for sour gas service.Nominal line size .................... : 3”Standard rating ..................... : 5000 / 10000 / 15000 PSI.Temperature rating ............... : -29°C to 121°C.Inspection level per API ........ : PSL2.WEIGHTS & DIMENSIONSLength in mm 1200Width in mm 500Height in mm 1660Weight in kg 610OPTIONS- 2” or 4” ESD valve size.- Hand pump.- Additional pumps.- Additional process inputs (fusible plug/fire detection,gas alarms, etc.) up to a Full Blown ”Process Panel”.- Specific inspection level on customer request.(PSL3, PED certification & CE marking, etc.).- DNV 2.7.3 or 2.7.1 certified skid.3 1/8 ” x 5000 PSI ESD Valve c/wportable control panel and remote ESD stations

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!