Input of Brand “X” Double Conversion UPSat Full Linear LoadVolts400Powerware InputAmps20003001500200100010050000-100-500-200-1000CVCI-300-1500AV-400-200017:21:22,000 17:21:22,005 17:21:22,010 17:21:22,015 17:21:22,020CHA Volts CHB Volts CHC Volts CHA Amps CHB Amps CHC AmpsBIBVAITimed event at 12.10.2000 17:21:22,000Sync channel =CHA (4 WIRE 3 PROBE)Unit A B C D ABCV 268.1 269.8 269.0 268.8 269.0I 645.6 649.4 647.4 0.0 1942.5kW 144.0 146.4 145.1 0.0 435.5kVA 173.1 175.2 174.2 0.0 522.5kVAR 96.0 96.2 96.3 0.0 288.6PF 0.832 0.836 0.833 0.000 0.834VTHD 5.87 5.63 5.85 5.95ITHD 29.76 29.90 30.17 0.00V H3 2.9 2.8 2.4 3.2I H3 0.5 0.0 0.3 0.0KFact 6.3 6.4 6.5 0.0Demand 131.8 134.4 133.1 0.0 399.2 (kW)Energy 60.1 62.7 62.0 0.0 184.7 (kWh)ICF 4.3 1.9 1.6 0.0HZ 60.0Vunbal 0.3Critical Facilities Round Table8/27/2004Power Conversion Technology Options
Input of Brand “X” Double Conversion UPSat 25% Linear LoadVolts400Powerware InputAmps100030075020050010025000-100-250-200-500CVCI-300-750AV-400-100017:10:16,000 17:10:16,005 17:10:16,010 17:10:16,015 17:10:16,020CHA Volts CHB Volts CHC Volts CHA Amps CHB Amps CHC AmpsBIBVAITimed event at 12.10.2000 17:10:16,000Sync channel =CHA (4 WIRE 3 PROBE)Unit A B C D ABCV 275.4 276.0 274.2 275.2 275.2I 181.1 182.5 181.3 0.0 544.9kW 37.7 38.2 37.8 0.0 113.7kVA 49.9 50.4 49.7 0.0 149.9kVAR 32.6 32.8 32.3 0.0 97.7PF 0.756 0.759 0.760 0.000 0.758VTHD 3.63 3.30 3.45 3.24ITHD 44.80 44.78 45.17 0.00V H3 2.8 2.5 2.8 2.6I H3 0.4 0.7 1.3 0.0KFact 11.5 8.7 9.3 0.0Demand 38.0 38.1 37.7 0.0 113.8 (kW)Energy 46.3 48.7 48.1 0.0 143.1 (kWh)ICF 15.0 2.0 2.7 0.0HZ 60.0Vunbal 0.4Critical Facilities Round Table8/27/2004Power Conversion Technology Options
- Page 1 and 2: Rotary and Static UPS TechnologiesP
- Page 3 and 4: “Incompatible”MGDCG/MCritical F
- Page 5 and 6: Hybrid Rotary UPSAuto Bypass Breake
- Page 7 and 8: Kinetic Diesel UPSUtilityContactorT
- Page 9 and 10: Delta Conversion UPSAutomatic Stati
- Page 11: UPS Input Parameters That ImpactOn-
- Page 15 and 16: Input of Brand “Y” Double Conve
- Page 17 and 18: Brand “Y” Double Conversion UPS
- Page 19 and 20: Input of Delta Conversion UPSat Ful
Input of Br<strong>and</strong> “X” Double Conversion <strong>UPS</strong>at 25% Linear LoadVolts400Powerware InputAmps100030075020050010025000-100-250-200-500CVCI-300-750AV-400-100017:10:16,000 17:10:16,005 17:10:16,010 17:10:16,015 17:10:16,020CHA Volts CHB Volts CHC Volts CHA Amps CHB Amps CHC AmpsBIBVAITimed event at 12.10.2000 17:10:16,000Sync channel =CHA (4 WIRE 3 PROBE)Unit A B C D ABCV 275.4 276.0 274.2 275.2 275.2I 181.1 182.5 181.3 0.0 544.9kW 37.7 38.2 37.8 0.0 113.7kVA 49.9 50.4 49.7 0.0 149.9kVAR 32.6 32.8 32.3 0.0 97.7PF 0.756 0.759 0.760 0.000 0.758VTHD 3.63 3.30 3.45 3.24ITHD 44.80 44.78 45.17 0.00V H3 2.8 2.5 2.8 2.6I H3 0.4 0.7 1.3 0.0KFact 11.5 8.7 9.3 0.0Dem<strong>and</strong> 38.0 38.1 37.7 0.0 113.8 (kW)Energy 46.3 48.7 48.1 0.0 143.1 (kWh)ICF 15.0 2.0 2.7 0.0HZ 60.0Vunbal 0.4<strong>Critical</strong> <strong>Facilities</strong> <strong>Round</strong> <strong>Table</strong>8/27/2004Power Conversion Technology Options