12.07.2015 Views

WDP100-AL English.pdf - Munters

WDP100-AL English.pdf - Munters

WDP100-AL English.pdf - Munters

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Evaporative Humidifier<strong>WDP100</strong>-<strong>AL</strong>Water Distribution SystemEQUIPMENT<strong>WDP100</strong>-<strong>AL</strong>• Excellent durability – extrudedaluminium• Corrosion resistant• Quick and easy installation:– longer distances betweenmounting brackets– perforated water distributionpipe is incorporated into the topaluminium gutter• Complete watering kits• Neat finishThe <strong>WDP100</strong>-<strong>AL</strong> water distribution system from <strong>Munters</strong> provides highlydurable means of mounting 100 mm thick CELdek ® evaporative coolingpads and supplying water to the pads. Together these form an ideal completesystem for incorporating evaporative cooling into the ventilation system of astructure.Corrosion of metal parts is a frequent problem amongst gutters used tomount evaporative cooling pads. This leads to frequent leaks and a short lifeexpectancy on such systems. Additionally a lot of time can be wasted onmaintenance by trying to keep the system functional. In order to reduce thetime and money spent on such unnecessary activities and increase the lifeexpectancy of such a system, all the parts of the <strong>WDP100</strong>-<strong>AL</strong> system aremanufactured in either extruded aluminium or plastic, which provides for anextremely durable system.The main structural components of the system are the top and bottomextruded aluminium gutters. They have the dual purpose of holding the padsas well as distributing the water. A perforated water distribution pipe with aunique self cleaning shape is incorporated into the top gutter. This allowsfor the even distribution of water onto the top of the pads, eliminating drystreaks in the pads. In such dry streaks no evaporative cooling can take placeand consequently hot dry air can enter the structure through such spaceseven while the system is in operation. The extruded aluminium channels arevery sturdy which allows for a longer distance between mounting brackets.


Order informationTop and bottom gutterBy using the combination of lengthsavailable any total length upwards from1.2 m is possible, using 0.6 m increments.Each gutter kit consist of the followingequipment:1 x top aluminium gutter,1 x bottom aluminium gutter,1 x top plastic connection piece,1 x bottom connection piece,2 x top stainless steel mounting brackets,2 x bottom stainless steel brackets.Aluminium gutter lengthOrdering code3.0 m WDP-100-<strong>AL</strong>-GU-30001.8 m WDP-100-<strong>AL</strong>-GU-18001.2 m WDP-100-<strong>AL</strong>-GU-1200Gutter sidesThe gutter side kit provides a neat endingand prevents water spillage from thepads. It also provides a plumbing kitthat can be used for cleaning the waterdistribution pipe. One kit is required persection. Each kit consists of the followingequipment:2 x top plastic ends,2 x bottom plastic ends,2 x aluminium end sections,2 x plastic plumbing kits with plasticpiping, connections and valve.Pad heightOrdering code1.2 m WDP-100-<strong>AL</strong>-SD-12001.5 m WDP-100-<strong>AL</strong>-SD-15001.8 m WDP-100-<strong>AL</strong>-SD-1800Drain kitThe drain kit is used to channel thereturn water back from the bottom gutterto the water tank. It consists of thefollowing equipment:1 x plastic spigot,1 x flexible pipe (12 m long),plastic connections, clamp and mountingscrews.Kit typeDrain KitOrdering codeWDP-100-<strong>AL</strong>-DK


Watering kitTwo watering kits are available.Watering Kit-A has a 300 l tank and 0.5hp submersible pump while wateringKit-B has a 500 l tank with a 0.75 hpsubmersible pump. A pump stand canbe placed in the bottom of the tankwhen the pump is installed. This preventsthe pump from sucking up anypossible dirt that might accumulatethere. The kits can be used for all installationoptions listed above. Each kitconsists of the following equipment:1 x submersible pump with float valve,1 x plastic tank,1 x in-line filter, connection for bleed-off,plastic piping, connections and valves,2 x silicone tubes for installation,1 x PVC glue tube for piping,1 x installation manual,1 x stainless steel pump stand.Technical specificationsWatering Kit-AWatering Kit-BKit typeOrdering codeElectricity supply 230 VAC 50 or 60 Hz 230 VAC 50 or 60 HzCurrent 2.1 A 3.5 APhases 1 1Power 0.5 hp 0.75 hpA (50 Hz electrical supply)A (60 Hz electrical supply)B (50 Hz electrical supply)B (60 Hz electrical supply)WDP-100-<strong>AL</strong>-WK-A-50WDP-100-<strong>AL</strong>-WK-A-60WDP-100-<strong>AL</strong>-WK-B-50WDP-100-<strong>AL</strong>-WK-B-60The diagram below indicates the sizes of all the external plumbing connections that can be made,25mm nipple for hose connection20mm nipple for hose connection1/2” male thread – water pressure at least 1 barOrdering code – exampleTo complete an installation with a gutter length of 19.2 m and a pad height of 1.5 m,the following equipment needs to be ordered.6 x WDP-100-<strong>AL</strong>-GU-30001 x WDP-100-<strong>AL</strong>-GU-12001 x WDP-100-<strong>AL</strong>-SD-15001 x WDP-100-<strong>AL</strong>-WK-A-50 (for 50Hz electrical supply).1 x WDP-100-<strong>AL</strong>-DK<strong>WDP100</strong>-<strong>AL</strong> cooling system is developed and produced by <strong>Munters</strong> Italy, S.p.A., Italy.<strong>Munters</strong> Europe AB, HumiCool Division, Kung Hans Väg 8, P.O. Box 434, SE-191 24 Sollentuna, Sweden. Phone +46 8 626 63 00, Fax +46 8 754 56 66.<strong>Munters</strong> Italy S.p.A., Strada Piani 2, IT-18027 Chiusavecchia, Italy. Phone +39 0183-52 11, Fax +39 0183-521 333.www.munters.comAustralia <strong>Munters</strong> Pty Limited, Phone +61 2 6025 6422, Fax +61 2 6025 8266, Austria via sales organization in Germany, Brazil <strong>Munters</strong> Brasil Industria eComercio Ltda, Phone +55 11 5054 0150, Fax +55 11 5054 0883, China <strong>Munters</strong> Air Treatment Equipment (Beijing) Co., Ltd., Phone +86 10 80 481 121, Fax+86 10 80 483 493, Denmark via sales organization in Sweden, Finland <strong>Munters</strong> Oy, Phone +358 9 83 86 030, Fax +358 9 83 86 0336, France <strong>Munters</strong> FranceS.A., Phone +33 1 34 11 57 50, Fax +33 1 34 11 57 51, Germany <strong>Munters</strong> Euroform GmbH, Phone +49 241 89 00 0, Fax +49 241 89 00 5199, Indonesia<strong>Munters</strong>, Phone +62 21 9105446-7, Fax +62 21 5310509, Italy <strong>Munters</strong> Italy S.p.A., Phone +39 0183-52 11, Fax +39 0183-521 333, Japan <strong>Munters</strong> K.K.,Phone +81 3 5970 0021, Fax +81 3 5970 3197, Kingdom of Saudi Arabia and Middle East Hawa <strong>Munters</strong>, c/o Hawa United Cooling Syst. Co. Ltd., Phone+966 1 477 15 14, Fax +966 1 476 09 36, Korea <strong>Munters</strong> Korea Co,. Ltd, Phone +82 2 761 8701, Fax +82 2 761 8777, Mexico <strong>Munters</strong> Mexico Phone +52722 270 40 30, Fax +52 722 270 41 95, Norway via sales organization in Sweden, South Africa and Sub-Sahara Countries <strong>Munters</strong> (Pty) Ltd, Phone +27 11971 9700, Fax +27 11 971 9701, Spain <strong>Munters</strong> Spain S.A., Phone +34 91-640 09 02, Fax +34 91-640 11 32, Sweden <strong>Munters</strong> Europe AB, Phone +46 8 62663 00, Fax +46 8 754 56 66, Switzerland via sales organization in Germany, Thailand <strong>Munters</strong> (Thailand) Co. Ltd., Phone +66 2 645 2708-12, Fax +66 2 6452710, United Kingdom <strong>Munters</strong> Ltd, Phone +44 845 644 3980, Fax +44 845 644 3981, USA <strong>Munters</strong> Corporation Fort Myers, Phone+1 239 936 1555, Fax +1 239 936 8858, <strong>Munters</strong> Corporation Mason, Phone +1 888 335 0100, Fax +1 517 676 7078, Export & Other countries <strong>Munters</strong>Europe AB, Phone +46 8 626 63 00, Fax +46 8 754 56 66.Your closest distributorHC/MMA/EqGB-0639-04/06 2000 SOS ReklamStudio ® CELdek is a registered trademark of Carl <strong>Munters</strong> AB.<strong>Munters</strong> reserves the right to make alterations to specifications, quantities, etc., for production or other reasons, subsequent to publication.© <strong>Munters</strong> Europe AB, 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!