äTroubleshooting <strong>Proline</strong> <strong>Promass</strong> 83No. Error message / Type Cause Remedy (spare partä 95)No. # 6xx Simulation mode activeä601 S: POSITIVE ZERO RETURN!: # 601Positive zero return active." Caution!This message has the highest display priority.Switch off positive zero return.611to614S: SIM. CURR. OUT. n!: # 611 to 614Simulation current output active.621to624S: SIM. FREQ. OUT n!: # 621 to 624Simulation frequency output active.Switch off simulation.631to634S: SIM. PULSE n!: # 631 to 634Simulation pulse output active.Switch off simulation.641to644S: SIM. STAT. OUT. n!: # 641 to 644Simulation status output active.Switch off simulation.651to654S: SIM. RELAY n!: # 651 to 654Simulation relay output active.Switch off simulation.661to664S: SIM. CURR. IN n!: # 661 to 664Simulation current input active.Switch off simulation.671to674S: SIM. STAT IN n!: # 671 to 674Simulation status input active.Switch off simulation.691 S: SIM. FAILSAFE!: # 691692 S: SIM. MEASURAND!: # 692698 S: DEV. TEST AKT.!: # 698Simulation of response to error (outputs) active.Simulation of measuring variables (e.g. mass flow).The measuring device is being checked on site via thetest and simulation device.Switch off simulation.Switch off simulation.No. # 8xx Other error messages with software options (Coriolis flowmeter)800 S: M. FL. DEV. LIMIT!: # 800Advanced Diagnostics: The mass flow is outside thelimit value, set in the corresponding diagnosis function.801 S: DENS. DEV. LIMIT!: # 801802 S: REF. D. DEV. LIM.!: # 802Advanced Diagnostics: The density is outside the limitvalue, set in the corresponding diagnosis function.Advanced Diagnostics: The reference density is outsidethe limit value, set in the corresponding diagnosisfunction.803 S: TEMP. DEV. LIMIT!: # 803804 S: T. DAMP DEV. LIM!: # 804Advanced Diagnostics: The temperature is outside thelimit value, set in the corresponding diagnosis function.Advanced Diagnostics: The tube damping is outside thelimit value, set in the corresponding diagnosis function.805 S: E.D. SEN. DEV. LIM!: # 805806 S: F. FLUCT. DEV. LI!: # 806807 S: TD FLUCT. DEV. LI!: # 807Advanced Diagnostics: The electrodynamic sensor isoutside the limit value, set in the correspondingdiagnosis function.Advanced Diagnostics: The fluctuation of the operatingfrequency is outside the limit value set in thecorresponding diagnosis functions.Advanced Diagnostics: The fluctuation of the pipedamping is outside the limit value set in thecorresponding diagnosis functions.Page 90 • MN0M022Issue/Rev. 0.2 (12/12)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!