<strong>Proline</strong> <strong>Promass</strong> 83äTroubleshootingNo. Error message / Type Cause Remedy (spare partä 95)363 S: CUR IN. RANGE!: # 363Current input:The actual value for the current lies outside the setlimits.1. Change set lower-rangeäor upper-range value.2. Check settings of the external sensor.379to380S: FREQ. LIM$: # 379 to 380The measuring tube oscillation frequency is outside thepermitted range.Causes:– Measuring tube damaged– Sensor defective or damagedContact your E+H service organization.381 S: FLUIDTEMP.MIN.$: # 381382 S: FLUIDTEMP.MAX.$: # 382383 S: CARR.TEMP.MIN$: # 383384 S: CARR.TEMP.MAX$: # 384385 S: INL.SENS.DEF.$: # 385386 S: OUTL.SENS.DEF.$: # 386387 S: SEN.ASY.EXCEED$: # 387388to390S: AMP. FAULT$: # 388 to 390No. # 5xx Application error501 S: SW.-UPDATE ACT.!: # 501502 S: UP-/DOWNLOAD ACT.!: # 502571 S: BATCH RUNNING!: # 571The temperature sensor on the measuring tube is likelydefective.The temperature sensor on the carrier tube is likelydefective.One of the measuring tube exciter coils (inlet) is likelydefective.One of the measuring tube exciter coils (outlet) is likelydefective.Measuring pipe excitation coil is probably faulty.Amplifier errorNew amplifier or communication (I/O module)software version is loaded. Currently no otherfunctions are possible.Up- or downloading the device data via configurationprogram. Currently no other functions are possible.Batching is started and active (valves are open).Check the following electrical connections before you contactyour E+H service organization:– Verify that the sensor signal cable connector is correctlyplugged into the amplifier board.– Remote version:Check sensor and transmitter terminal connections No. 9and 10. ä 26Check the following electrical connections before you contactyour E+H service organization:– Verify that the sensor signal cable connector is correctlyplugged into the amplifier board.– Remote version:Check sensor and transmitter terminal connections No. 11and 12. ä 26Check the following electrical connections before you contactyour E+H service organization:– Verify that the sensor signal cable connector is correctlyplugged into the amplifier board.– Remote version:Check sensor and transmitter terminal connections No. 4, 5, 6and 7. ä 26Contact your service organization.Wait until process is finished. The device will restartautomatically.Wait until process is finished.No measures needed (during the batching process some otherfunctions may not be activated).572 S: BATCH HOLD!: # 572Batching has been interrupted (valves are closed). 1. Continue batching with command "GO ON".2. Interrupt batching with "STOP" command.586 S: OSC. AMP. LIMIT$: # 586587 S: TUBE OSC. NOT$: # 587588 S: GAIN RED.IMPOS$: # 588The fluid properties do not allow a continuation of themeasurement.Causes:– Extremely high viscosity– Process fluid is very inhomogeneous (gas or solidcontent)Extreme process conditions exist. The measuringsystem can therefore not be started.Overdriving of the internal analog to digital converter.Causes:– Cavitation– Extreme pressure pulses– High gas flow velocityA continuation of the measurement is no longerpossible!Change or improve process conditions.Change or improve process conditions.Change or improve process conditions, e.g. by reducing the flowvelocity.Issue/Rev. 0.2 (12/12) MN0M022 • Page 89

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!