12.07.2015 Views

Proline Promass 83E/F/O Operation Manual - FMC Technologies

Proline Promass 83E/F/O Operation Manual - FMC Technologies

Proline Promass 83E/F/O Operation Manual - FMC Technologies

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Proline</strong> <strong>Promass</strong> 83äTroubleshootingNo. Error message / Type Cause Remedy (spare partä 95)S = System error$ = Fault message (with an effect on the outputs)! = Notice message (without any effect on the outputs)äNo. # 0xx Hardware error001 S: CRITICAL FAILURE$: # 001011 S: AMP HW EEPROM$: # 011012 S: AMP SW EEPROM$: # 012031 S: SENSOR HW DAT$: # 031032 S: SENSOR SW DAT$: # 032041 S: TRANSM. HW DAT$: # 041042 S: TRANSM. SW DAT$: # 042051 S: A / C COMPATIB.$: # 051061 S: HW F-CHIP$: # 061No. # 1xx Software errorSerious device errorAmplifier:Defective EEPROMMeasuring amplifier: Error when accessing data of theEEPROM1. S-DAT is not plugged into the amplifier boardcorrectly (or is missing).2. S-DAT is defective.1. T-DAT is not plugged into the amplifier boardcorrectly (or is missing).2. T-DAT is defective.The I/O board and the amplifier board are notcompatible.F-Chip transmitter:1. F-Chip is defective.2. F-Chip is not plugged into the I/O board or ismissing.Replace the amplifier board.Replace the amplifier board.The EEPROM data blocks in which an error has occurred aredisplayed in the TROUBLESHOOTING function.Press Enter to acknowledge the errors in question; default valuesare automatically inserted instead of the errored parameter values.! Note!The measuring device has to be restarted if an error has occurredin a totalizer block (see also error No. 111 / CHECKSUMTOTAL.).1. Check whether the S-DAT is correctly plugged into theamplifier board.2. Replace the S-DAT if it is defective.Check that the new, replacement DAT is compatible with themeasuring electronics.Check the:- Spare part set number- Hardware revision code3. Replace measuring electronics boards if necessary.4. Plug the S-DAT into the amplifier board.1. Check whether the T-DAT is correctly plugged into theamplifier board.2. Replace the T-DAT if it is defective.Check that the new, replacement DAT is compatible with themeasuring electronics.Check the:- Spare part set number- Hardware revision code3. Replace measuring electronics boards if necessary.4. Plug the T-DAT into the amplifier board.Use only compatible modules and boards.Check the compatibility of the modules used.Check the:– Spare part set number– Hardware revision code1. Replace the F-Chip.Accessories ä 832. Plug the F-Chip into the I/O board.111 S: CHECKSUM TOTAL.$: # 111Totalizer checksum error 1. Restart the measuring device2. Replace the amplifier board if necessary.121 S: A / C COMPATIB.!: # 121No. # 2xx Error in DAT / no communicationDue to different software versions, I/O board andamplifier board are only partially compatible (possiblyrestricted functionality).! Note!– This message is only listed in the error history.– Nothing is displayed on the display.Module with lower software version has either to be actualized byFieldCare with the required software version or the module has tobe replaced.Issue/Rev. 0.2 (12/12) MN0M022 • Page 87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!