Proline Promass 83E/F/O Operation Manual - FMC Technologies
Proline Promass 83E/F/O Operation Manual - FMC Technologies
Proline Promass 83E/F/O Operation Manual - FMC Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Proline</strong> <strong>Promass</strong> 83CommissioningFig. 44:Selecting and configuring different density functions in the function matrixBrixgrade (density of hydrous saccharose solution in kg/m³)°Brix 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C0 999.70 998.20 995.64 992.21 988.03 983.19 977.76 971.785 1019.56 1017.79 1015.03 1011.44 1007.14 1002.20 996.70 989.6510 1040.15 1038.10 1035.13 1031.38 1026.96 1021.93 1016.34 1010.2315 1061.48 1059.15 1055.97 1052.08 1047.51 1042.39 1036.72 1030.5520 1083.58 1080.97 1077.58 1073.50 1068.83 1063.60 1057.85 1051.6325 1106.47 1103.59 1099.98 1095.74 1090.94 1085.61 1079.78 1073.5030 1130.19 1127.03 1123.20 1118.80 1113.86 1108.44 1102.54 1096.2135 1154.76 1151.33 1147.58 1142.71 1137.65 1132.13 1126.16 1119.7940 1180.22 1176.51 1172.25 1167.52 1162.33 1156.71 1150.68 1144.2745 1206.58 1202.61 1198.15 1193.25 1187.94 1182.23 1176.14 1169.70Issue/Rev. 0.2 (12/12) MN0M022 • Page 71