Commissioning <strong>Proline</strong> <strong>Promass</strong> 836 Commissioning6.1 Function checkMake sure that the following function checks have been performed successfully before switching onthe supply voltage for the measuring device:• Checklist for "Post-installation check" ä 25• Checklist for "Post-connection check" ä 326.2 Switching on the measuring deviceOnce the function check has been performed successfully, the device is operational and can beswitched on via the supply voltage. The device then performs internal test functions and thefollowing messages are shown on the local display:PROMASS 83START-UPRUNNINGStartup messagePROMASS 83▼DEVICE SOFTWAREV XX.XX.XXCurrent software version▼CURRENT OUTPUTFREQUENCY OUTPUTRELAYSTATUS INPUTList of installed input/output modules▼SYSTEM OK OPERATIONBeginning of normal measuring mode▼!Note!Normal measuring mode commences as soon as startup completes.Various measured value and/or status variables appear on the display (HOME position).If startup fails, an error message indicating the cause is displayed.Page 54 • MN0M022Issue/Rev. 0.2 (12/12)