12.07.2015 Views

Lateral Line March 2011 - Hill Country Cichlid Club

Lateral Line March 2011 - Hill Country Cichlid Club

Lateral Line March 2011 - Hill Country Cichlid Club

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

13rack frame, but if your rack is like mine,then you are up a creek. Wood is not a goodgrounding conductor.As a backup solution, I thought to install astainless steel foil sheet behind all of mylights. I need to ensure that I am touchingthe Stainless steel sheet whenever I amworking with the electricity in the fish room.Doing do will ensure that if I get shocked, Iwill probably not be killed. I selectedStainless steel foil for 2 reasons. (1) it doesn’trust and (2) aluminum was not a goodoption because it reacts in humid environmentswith copper and I am using copperwire.For other instructions on how to build thelight fixture, I recommend trial and error andlook at the pictures. It will be for me to explainever little thing that needs to be donewhen building the lights. I figured that thebest I can do is take pictures of the installationfrom every angle and let you figure itout for yourselves.The Testing:In an attempt to be as scientific and unbiasedas possible, I borrowed a light meter fromwork. I placed the light meter at ten inch intervalsdown the length of the rack. I placeda white reflector underneath the test meterand another white reflector on the shelfabove the test rack. The readings were takensix inches from the front of the rack and sixinches from the back of the rack. Figure 4displays the test locations while comparingthe three lighting systems. The measurementswere taken after each light had fiveminutes to warm up and with all other roomlights off.The test results are displayed in Table 7. Allunits of measurements are in Foot-Candles,a standard measuring unit for light levels.The T8 light fixture had by far the highestoutput light level of the 3 systems, but it alsohas the highest power input. The T8 lampswere also 3½ inches closer to the light meterbecause they intrude into the clearance spacebetween the rack and the aquarium. In acomparison of light per watt of electricity,the clear winner is the LED light fixture. Toincrease the light level, additional LEDlamps can be installed if desired.Cost of Ownership Analysis:As part of the cost of ownership I must includethe following items:1. Capital Installation Cost (100% in thefirst year)2. Monthly Electricity Cost3. Lamp Replacement CostCFL lamps have an average life of 10,000hours. This means that they will require replacementevery 4 ½ years. In comparison,the T8 florescent lamps have an average lifeof 25,000 years and will only need to be replacedevery 11.5 years. The LED lamps

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!