Installation/startup instruction (English) - PNet - Trend
Installation/startup instruction (English) - PNet - Trend Installation/startup instruction (English) - PNet - Trend
Trouble ShootingA2Trouble Shooting (continued)10. Analyse the communications to find any faults Knowledge of MODBUS protocol is required.11. When the analysis is complete in the Debug Active box select ‘OFF’, and click .44 IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-2011
IndexIndexAAboutIQ3/XNC3 MODBUS Driver .................................................7This Manual .......................................................................5, 7BBaud Rate ...........................................................................................22CCOM error ....................................................................................22, 23ConfigureDriver Using a Solution ................................................. 13, 14IQ3/XNC3 Mbus Driver ......................................................19IQ3/XNC3 Strategy ..............................................................33Connect the IQ3/XNC3 to the MODBUS ..........................................15Contacting Trend ..................................................................................5DData Bits .............................................................................................22Download the Strategy .......................................................................35IInstall and Configure the IQ3/XNC MODBUS Driver .....................13Install the IQ3/XNC MODBUS Driver Files ....................................11LLink the Modules to the Required Connectives ................................33Link the XNC Application File ..........................................................20PParity ...................................................................................................22Port Types ...........................................................................................22RRS232 ..................................................................................................22RS485..................................................................................................22SServer ..................................................................................................27Specifying a different server .............................................................27Stop Bits ..............................................................................................22TTimeout ...............................................................................................22XXNC Interface Module ........................................ 14, 20, 22, 23, 31, 34IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-201145
- Page 5 and 6: About this Manual1 About this Manua
- Page 7: About the IQ3/XNC MODBUS Driver2 Ab
- Page 13 and 14: Configuration Process4 Configuratio
- Page 15 and 16: T T RA RB0VTXRXRTS / TXENCTS / RXEN
- Page 17 and 18: 0VT T RA RBRTS / TXENCTS / RXENTXRX
- Page 19 and 20: Configure the IQ3/XNC MODBUS Driver
- Page 21 and 22: Configure the IQ3/XNC MODBUS Driver
- Page 23 and 24: Configure the IQ3/XNC MODBUS Driver
- Page 25 and 26: Configure the IQ3/XNC MODBUS Driver
- Page 27 and 28: Configure the IQ3/XNC MODBUS Driver
- Page 29 and 30: Configure the IQ3/XNC MODBUS Driver
- Page 31 and 32: Configure the IQ3/XNC MODBUS Driver
- Page 33 and 34: Configure the IQ3/XNC Strategy7 Con
- Page 35 and 36: Configure the IQ3/XNC Strategy7.3 D
- Page 37 and 38: Configuration ExampleAppendicesA1Co
- Page 39 and 40: Configuration ExampleA1Configuratio
- Page 41 and 42: Configuration ExampleA1Configuratio
- Page 43: Trouble ShootingA2Trouble ShootingT
- Page 47 and 48: IQ3/XNC MODBUS Driver Manual TE2011
Trouble ShootingA2Trouble Shooting (continued)10. Analyse the communications to find any faults Knowledge of MODBUS protocol is required.11. When the analysis is complete in the Debug Active box select ‘OFF’, and click .44 IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-2011