Installation/startup instruction (English) - PNet - Trend
Installation/startup instruction (English) - PNet - Trend Installation/startup instruction (English) - PNet - Trend
Configure the IQ3/XNC MODBUS Driver6.4.1.1.5 Bit write. (MODBUS Function 5)The example below shows a store configured to write 1 bit at MODBUS address 21 in device 1. The IQ3/XNCretrieves the value to write from the TCL input 1.E001#F05#A00021#N01#I001#C0000 Format type (always 00 for function 5)0001 TCL input of value to write. (This would normally be linked to adigital point in the strategy e.g. reset switch).01 Number of values to write (always 1)00021 Location value to write to.05 MODBUS function (function 5)001 device number6.4.1.1.6 16 bit word write (MODBUS function 6)The example below shows a store configured to write 1 word at MODBUS address 20 in device 1. The IQ3/XNCretrieves the value to write from the TCL input 2.E001#F06#A00020#N01#I002#C02#MS/LSMS/LS Least significant bit first02 Format type0002 TCL input of value to write. (This would normally be linked to ananalogue point in the strategy e.g. setpoint).01 Number values to write (always 1)00020 Location of value to write to.06 MODBUS function (function 6)001 device number30 IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-2011
Configure the IQ3/XNC MODBUS Driver6.4.1.1.7 Multiple 16 bit word write (MODBUS function 16)The example below shows a store configured to write 2 words at MODBUS address 27 in device 1. The IQ3/XNC3retrieves the first value from TCL input 3 to be written to MODBUS address 27, then the second from TCL input 4to be written to MODBUS address 28.E001#F16#A00027#N02#I003#C01#MS/LSMS/LS Most significant bit first12 Format type0002 TCL input of first value to write02 Number values to write00027 Location of first value to write to.16 MODBUS function (function 16)001 device number6.5 Configure Input/Output LabelsTo make identification of the inputs and outputs easier when linking them to the strategy it is recommend that thetheir labels are configured so that they are understandable. They could be set to match those supplied by the device.To configure the input/output labels:1. Run SET, open the SET project, display a strategy page for the IQ3/XNC, right-click a strategy page, point toDevice and click XNC Interface Module. The XNC Interface Module dialogue box is displayed.2. In the Inputs or Outputs area double-click on the label that is to be specified.3. Enter the new label.4. Click OK.Labels can be copied and pasted by right-clicking on the label and clicking Copy Label or Paste Label. Labels can bepasted into more than one input, or output by copying the required information to the clipboard, the information foreach input or output must be on a new line, selecting the required input or output, right-clicking, and clicking Paste.Clicking Select All will select all the labels.IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-201131
- Page 5 and 6: About this Manual1 About this Manua
- Page 7: About the IQ3/XNC MODBUS Driver2 Ab
- Page 13 and 14: Configuration Process4 Configuratio
- Page 15 and 16: T T RA RB0VTXRXRTS / TXENCTS / RXEN
- Page 17 and 18: 0VT T RA RBRTS / TXENCTS / RXENTXRX
- Page 19 and 20: Configure the IQ3/XNC MODBUS Driver
- Page 21 and 22: Configure the IQ3/XNC MODBUS Driver
- Page 23 and 24: Configure the IQ3/XNC MODBUS Driver
- Page 25 and 26: Configure the IQ3/XNC MODBUS Driver
- Page 27 and 28: Configure the IQ3/XNC MODBUS Driver
- Page 29: Configure the IQ3/XNC MODBUS Driver
- Page 33 and 34: Configure the IQ3/XNC Strategy7 Con
- Page 35 and 36: Configure the IQ3/XNC Strategy7.3 D
- Page 37 and 38: Configuration ExampleAppendicesA1Co
- Page 39 and 40: Configuration ExampleA1Configuratio
- Page 41 and 42: Configuration ExampleA1Configuratio
- Page 43 and 44: Trouble ShootingA2Trouble ShootingT
- Page 45 and 46: IndexIndexAAboutIQ3/XNC3 MODBUS Dri
- Page 47 and 48: IQ3/XNC MODBUS Driver Manual TE2011
Configure the IQ3/XNC MODBUS Driver6.4.1.1.7 Multiple 16 bit word write (MODBUS function 16)The example below shows a store configured to write 2 words at MODBUS address 27 in device 1. The IQ3/XNC3retrieves the first value from TCL input 3 to be written to MODBUS address 27, then the second from TCL input 4to be written to MODBUS address 28.E001#F16#A00027#N02#I003#C01#MS/LSMS/LS Most significant bit first12 Format type0002 TCL input of first value to write02 Number values to write00027 Location of first value to write to.16 MODBUS function (function 16)001 device number6.5 Configure Input/Output LabelsTo make identification of the inputs and outputs easier when linking them to the strategy it is recommend that thetheir labels are configured so that they are understandable. They could be set to match those supplied by the device.To configure the input/output labels:1. Run SET, open the SET project, display a strategy page for the IQ3/XNC, right-click a strategy page, point toDevice and click XNC Interface Module. The XNC Interface Module dialogue box is displayed.2. In the Inputs or Outputs area double-click on the label that is to be specified.3. Enter the new label.4. Click OK.Labels can be copied and pasted by right-clicking on the label and clicking Copy Label or Paste Label. Labels can bepasted into more than one input, or output by copying the required information to the clipboard, the information foreach input or output must be on a new line, selecting the required input or output, right-clicking, and clicking Paste.Clicking Select All will select all the labels.IQ3/XNC MODBUS Driver Manual TE201101 Issue 2, 12-Apr-201131