Technical parametersThe <strong>LAMBDA</strong> <strong>MINIFOR</strong> fermentor/<strong>bioreactor</strong> is controlled by two microprocessors.Power:Dimensions:Display:Fermentor vessel:Working volumes:Mains 100-240 V AC/50-60Hz, 510W, CE conform22x40x38cm (WxDxH)LCD 4 x 40 digits with backlight illuminationPyrex glass with 6 to 8 side necks 0.3, 0.4, 1, 3 and 7 l35ml to over 6 litersTemperature control:IR radiation heat source with gilded reflector 150WRegulation: from 5°C above RT to over 70°CMeasurement:from 0 to 99.9°C in 0.1°C stepsPrecision:± 0.2°C (0 to 60°C)Sensor:Pt 100 incorporated in the pH sensorpH control:Pumps:pO 2 control:Resolution:Precision:Range:sterilizable pH electrode (Mettler), pH 0-13, with automatictemperature correction, Variopin connector, two-pointsemiautomatic calibration0.01 pH unit± 0.02 pH unitup to 4 independent peristaltic pumps (PRECIFLOW,MULTIFLOW, HIFLOW or MAXIFLOW) with speed variationfrom 0 to 100 % can be used with <strong>MINIFOR</strong>sterilizable Clark type oxygen sensor, PEEK body, Mettlermembrane module, automatic temperature correction0 to 25 mg oxygen/l, in 0.1 mg/l steps, automatic controlthrough regulation of air flow rateAir flow:0 to 5 l/min. in 0.1 l/min. steps, mass flow meter, linearity± 3%,Reproducibility: ± 0.5%Control:proportional valvefor supplied air pressure:between 0.05 – 0.2 MPa (max.)Agitation:Selectable parameter:Sampling/addition ports:Working temperature: 0 - 40 °CWorking relative humidity:50 W Vibromixer 0 to 20 Hz (0 to 1200 rpm), in 0.1 Hzsteps, with 1 or more stirring discsSterility comparable to magnetic couplingan additional parameter can be controlled by theinstrument (foaming control, pCO 2 , optical density,conductivity, etc.)up to 4 stainless steel needles with <strong>LAMBDA</strong> PEEKdouble-seal fittings can be used for sampling and additionof correction solutions0 - 90 % RH (non condensing)Security: conform to IEC 1010/1Weight:PC control:Warranty:7.5 kgcomplete PC control and data treatment using FNet or SIAMfermentation software (optional)2 years<strong>LAMBDA</strong> Laboratory Instruments<strong>LAMBDA</strong> CZ s.r.o.Dr. Pavel Lehky Lozibky 1Imfeldsteig 12CZ-61400 BrnoCH-8037 ZürichCzech RepublicSwitzerlandTel: +41 (0)44 450 20 71 Tel/Fax: +420 545 578 643Fax: +41 (0)44 450 20 72 Hotline: +420 603 274 677E-mail: info@lambda-instruments.comWeb: www.lambda-instruments.comwww.<strong>bioreactor</strong>s.eu6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!