12.07.2015 Views

CC488 Solution Ultima 880 Control Panel - SourceSecurity.com

CC488 Solution Ultima 880 Control Panel - SourceSecurity.com

CC488 Solution Ultima 880 Control Panel - SourceSecurity.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2 | <strong>CC488</strong> <strong>Solution</strong> <strong>Ultima</strong> <strong>880</strong> <strong>Control</strong> <strong>Panel</strong>Codepad Tamper AlarmCodepad tamper limits the number of times thatsomeone can try to enter the wrong user code. Whensomeone exceeds the limit, the system starts an alarmand sends a report to a security monitoring station.Choice of End-Of-Line (EOL) Resistor ValueUsers can choose different EOL resistor values whenprogramming the control panel. The selected valueapplies to all zones at once. Users can add the controlpanel into an existing system without changing theEOL resistors.Built-in Telephone Line Fault MonitorWhen the system detects a telephone line failure, itcreates a telephone line fault. Users can program thesystem to sound an alarm if the telephone line is cutwhile the control panel is armed.Zone LockoutThe first zone to send an alarm condition is locked anda siren runs for a specified time. All other zones thatsend alarm conditions are reset when the sirens reset,but continue to report if another alarm conditionoccurs. This prevents an intruder from setting off thealarms in all zones, waiting for the sirens to stop, andthen entering the site.Automatic Battery TestingThe system performs a battery test each time a userarms the sys-tem, and automatically every four hours.When the system detects a low capacity back-upbattery, it creates a low battery fault.Event Memory RecallEvent Memory Recall plays the last 40 system events,including all alarms, system arming, and systemdisarming. If the control panel is partitioned, EventMemory Recall plays the last 10 system events.Programmable Ring Burst TimeTelephone ring times might be longer or shorterdepending on the technology in a system. Differenttiming can cause control panels to answer calls thatshould be answered by an answering machine, fax, ora person. Users can program the control panel for thecorrect ring burst time. Adjust the ring time from 0 msto 1200 ms in 5 ms increments.Call ForwardingThe tele<strong>com</strong>munications provider must offer a callforwarding option. Users can program call forwardingmodes to operate when the system is armed in theAWAY Mode.Call Forward Modes• Immediate On: Redirects all in<strong>com</strong>ing calls to anothernumber, including mobile phones, pagers, andanswering services. The telephone called first doesnot ring.• No Answer: Redirects all in<strong>com</strong>ing calls to anothernumber when the telephone that was called first isnot answered within 20 seconds. Outgoing calls canstill be made from the first telephone.Certifications and approvalsA-Tick Supplier CodeN663New Zealand Telepermit PTC 211/98/083RegionEuropeCertificationCECEInstallation/configuration notesCompatibility InformationRF ReceiversRF TransmittersRE005E RF Receiver with OutputsRE012E Two-channel Hand-held TransmitterRE013E Four-channel Hand-held TransmitterCodepads • CP105A Night Arm Station• CP500AW LED Area Addressable• CP500ALW LCD Area Addressable• CP500PW LED Partitionable• CP516LW LCD• CP516W LEDModulesTechnical specificationsEnclosureDimensions:Weight:MO144 Universal Timer Module30.6 cm x 26.2 cm x 8.4 cm(12 in x 10.3 in x 3.3 in)Packed in carton2.5 kg (5.5 lb)Environmental ConsiderationsRelative Humidity:Temperature (Operating):Power RequirementsCurrent Draw (Standby):Current Draw (Alarm):Current Draw (withCodepad):Primary:Secondary:Trademarks10% to 95% non-condensing0°C to +45°C (+32°F to +113°F)65 mA115 mA105 mA240 VAC, 18 VAC at 1.3 A from aTF008 Plug Pack12 VDC, 6 Ah from a rechargeablesealed lead/acid batteryMS-DOS ® is a registered trademark of Microsoft Corporation in theUnited States and/or other countries.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!