12.07.2015 Views

Residential Diaphragm Meters Technical Data - The Meter and ...

Residential Diaphragm Meters Technical Data - The Meter and ...

Residential Diaphragm Meters Technical Data - The Meter and ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Module Replacement ProgramBecause of the “single joint” design of the Sensusresidential meter, easy replacement of all internalworking parts is possible. A new measuring modulecan be installed simply by removing <strong>and</strong> replacingseveral screws.Listed below are the modules available for ourcurrent line of residential meters. <strong>The</strong>y are availablein st<strong>and</strong>ard or temperature compensatedconstruction <strong>and</strong> can be inserted into existing bodies<strong>and</strong> covers <strong>and</strong> calibrated in your shop.This program is important in your long-rangeplanning. It means that the Sensus meters youpurchase today can be updated to new conditionyears from now at about two-thirds of the costof new meters.Consider updating your meter population at afraction of the cost of new meters. For yourimmediate planning, many of the modules listedbelow fit into older meters--those currently in yoursystem that need attention now.Base Module Part Numbers<strong>Meter</strong> Non-Temperature TemperatureModel Compensated CompensatedS-275, R-275,R-315001-63-502-06 001-63-502-07MR-5, MR-8MR-9001-63-502-19 001-63-502-20#415 001-41-502-70 001-41-502-71MR-12 001-41-502-72 001-41-502-73<strong>The</strong> <strong>Meter</strong> ReplacementsSensus offers a complete line of residential meter replacements for the 5 Lt. <strong>and</strong> 10 Lt. tin meters,without any need for special connections or modifications to the meter set.<strong>The</strong> RT-230 has 5 Lt.connections on 11-1/4"centers <strong>and</strong> makes useof the internal workingparts of the R-275residential meter.RT-230210 SCFHNote:All capacities are maximum, basedon 0.6 specific gravity gas measuredat 4 oz. base pressure <strong>and</strong> 60° Fat 1/2" w.c. differential pressure –in accordance with B109.1specifications. Recommended meteroperating temperature range:-30° F to +150° F. See temperaturecompensation description page 7.RT-275250 SCFH<strong>The</strong> same R-275 is convertedto an RT-275 by fitting itwith 10 Lt. connections on11-1/4” centers.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!