12.07.2015 Views

Non-Condensing Models - AO Smith Water Heaters

Non-Condensing Models - AO Smith Water Heaters

Non-Condensing Models - AO Smith Water Heaters

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Troubleshooting Guide5.4 TROUBLESHOOTING ‐ PROCEDURESVerifying proper Dipswitch settings… p.19Draining the unit………………………………p.21Cleaning the filter…………………………….p.21Checking for a Cross Connection………p.21Check for Reverse Connection………….p.21Check gas supply pressure………………. p.21Purge the gas line of air………………….. p.22Adjusting manifold pressure…………….p.22Resetting the computer board………… p.23Checking the OHCF…………………………. p.24Figure 15VERIFYING PROPER DIPSWITCH SETTINGS:• Incorrect Dipswitch settings can cause a 031 error code, or a number of operational problems.Table 3 – 310 (T‐K4), 110 (T‐KJr2) Dipswitch SettingsNo. Function ON position OFF position1 Gas type Propane Disable2 Natural Gas Disable34FM+, FM++, FM+++ 110 Indoor (T‐KJr2‐IN), 310 Indoor (T‐K4‐IN)No.3OF position N positionNo.4 OFF position 0% +6%ON position +12% +18%110 Outdoor (T‐KJr2‐OS), 310 Outdoor (T‐K4‐OS)No.3OFF positionDipswitch BankON positionNo.4 OFF position 0% +4%ON position +8% +12%5 N/A N/A N/A (Default)6 Model type Outdoor 110 (T‐KJr2‐OS),Outdoor 310 (T‐K4‐OS)Indoor 110 (T‐KJr2‐IN),Indoor 310 (T‐K4‐IN)7 Output temperature settings (Default 122F)819| Page