PDG-DHT8000L Expand <strong>Serial</strong> Command Functional Specifications9.9.9 CR_LAMPCORRESPH CommandCommandDetailsResponse“CR_LAMPCORRESPH” [CR]Get Lamp running time (in hours)*return lamp running time multiplied by a coefficient (not actual running time)Acceptable“000_%1” [CR]%1 “00000”-“99999”Unacceptable“Error Code” [CR]9.9.10 CR_LAMPINTERVAL CommandCommandDetailsResponse“CR_LAMPINTERVAL” [CR]Get setting status of Lamp intervalAcceptable%1Unacceptable“000_%1” [CR]“AUTO” ---------------- Auto is selected“0024”------------------ 24 Hours is selected“0200”------------------ 200 Hours is selected“0500”------------------ 500 Hours is selected“1000”------------------ 1000 Hours is selected“2000”------------------ 2000 Hours is selected“OFF” ------------------ Off is selected“?” [CR]9.9.11 CR_LAMPLIFECONTRL CommandCommandDetailsResponse“CR_LAMPLIFECONTRL” [CR]Get setting status of Lamp life control.(Available only in the normal Power ON status)Acceptable“000_%1” [CR]%1 “MODE1” ---------------- Mode1 is selected“MODE2”----------------- Mode2 is selectedUnacceptable“Error Code” [CR]<strong>DHD800</strong> RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)80/101