Christie DHD800 Serial Communications Protocol-Extended
Christie DHD800 Serial Communications Protocol-Extended
Christie DHD800 Serial Communications Protocol-Extended
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
PDG-DHT8000L Expand <strong>Serial</strong> Command Functional Specifications9.4 Image Status Read Commands9.4.1 CR_CONT CommandCommand “CR_CONT” [CR]Details Get user controlled value of ContrastAcceptable “000_%1” [CR]Response %1 “000” – “063”Unacceptable “?” [CR]9.4.2 CR_BRIGHT CommandCommand “CR_BRIGHT” [CR]Details Get user controlled value of BrightnessAcceptable “000_%1” [CR]Response %1 “000” – “063”Unacceptable “?” [CR]9.4.3 CR_COLOR CommandCommandDetailsResponse“CR_COLOR” [CR]Get user controlled value of ColorAcceptable“000_%1” [CR]%1 “000” – “063”Unacceptable“Error Code” [CR] -----------When command is invalid in the givencondition (such as being selected input)“?” [CR] --------- When unknown command is received9.4.4 CR_TINT CommandCommandDetailsResponse“CR_TINT” CR]Get user controlled value of TintAcceptable“000_%1” [CR]%1 “000” – “063”Unacceptable“Error Code” [CR] -----------When command is invalid in the givencondition (such as being selected input)“?” [CR] --------- When unknown command is received9.4.5 CR_APCTRL CommandCommandDetailsResponse“CR_APCTRL” [CR]Get setting status of Auto Picture ControlAcceptable%1Unacceptable“000_%1” [CR]“L1” ------------------ Operate Auto Picture Control with Level1“L2” ------------------ Operate Auto Picture Control with Level2“OFF” --------------- Set Auto Picture Control OFF“?” [CR]<strong>DHD800</strong> RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)60/101