12.07.2015 Views

Christie DHD800 Serial Communications Protocol-Extended

Christie DHD800 Serial Communications Protocol-Extended

Christie DHD800 Serial Communications Protocol-Extended

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PDG-DHT8000L Expand <strong>Serial</strong> Command Functional Specifications8.9.15 CF_PIPMODEFREE CommandCommand%1DetailsResponse“CF_PIPMODEFREE_%1” [CR]“USER1” --------------------------- Set User1 to Free status“USER 2” -------------------------- Set User2 to Free status“USER 3” -------------------------- Set User3 to Free status“USER 4” -------------------------- Set User4 to Free status“USER 5” -------------------------- Set User5 to Free statusDelete the data registered in Custom User1–5 and returns it to Free status.This command operates the same way as resetting to User1-5 in “Picture inPicture” Menu.(Available only in the normal Power ON status)*When there is only one user mode of stored state, return “101” [CR]AcceptableUnacceptable“000” [CR]“Error Code” [CR]8.9.16 CF_PIPRST CommandCommand“CF_PIPRST_%1” [CR]%1 “RST” ---------------------- Reset current setting statusDetailsResponseReset current setting status of “Picture in Picture”.(Available only in the normal Power ON status)AcceptableUnacceptable“000” [CR]“Error Code” [CR]8.9.17 CF_EDGEBLENDING CommandCommand%1DetailsResponse“CF_EDGEBLENDING_%1” [CR]“ON” ---------------------- Set Edge blending to On“OFF” -------------------- Set Edge blending to OffSet Edge blending.(Available only in the normal Power ON status)The status set by this command is stored in EEPROM and setting remainseffective even after the power is turned to ALL OFF status.AcceptableUnacceptable“000” [CR]“Error Code” [CR]8.9.18 CF_BLEND CommandCommand%1%2DetailsResponse“CF_BLEND_%1_%2” [CR]“LEFT” ---------------------- Left side“RIGHT” -------------------- Right side“TOP” ----------------------- Upper side“BOTTOM” ---------------- Lower side“000”-“960”-------------------- Directly specify value of direction of %1*Value of upper limit changes by choice of %1Left ---------------------- 000~960Right -------------------- 000~960Top ---------------------- 000~540Bottom ----------------- 000~540Set value of direction specified by Edge blending %1.(Available only in the normal Power ON status)The status set by this command is stored in EEPROM and setting remainseffective even after the power is turned to ALL OFF status.AcceptableUnacceptable“000” [CR]“Error Code” [CR]<strong>DHD800</strong> RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)43/101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!