Christie DHD800 Serial Communications Protocol-Extended

Christie DHD800 Serial Communications Protocol-Extended Christie DHD800 Serial Communications Protocol-Extended

christiedigital.com
from christiedigital.com More from this publisher
12.07.2015 Views

PDG-DHT8000L Expand Serial Command Functional Specifications9.11.11 CR_OPTCTRLNO CommandCommand “CR_OPTCTRLNO”[CR]Details Get value of Option control No.Acceptable “000_%1” [CR]Response %1 Four digits of alphanumeric charactersUnacceptable “?” [CR]9.11.12 CR_LENSTYPE CommandCommand “CR_LENSTYPE”[CR]Details Get which type of Lens is currently installedAcceptable “000_%1” [CR]Response%1UnacceptableLens type %1On Axis Short Fixed LNS-W52 Lens (0.8:1)Short Zoom Lens LNS-W51 (1.2-1.5:1)Short Zoom Lens LNS-W50 (1.5-1.8:1)Short Zoom Lens LNS-W53 (1.2-1.8:1)Standard Zoom LNS-S50 Lens (1.8-2.8:1)Standard Zoom LNS-S51 Lens (1.8-2.8:1)Long Zoom Lens LNS-T50 (2.8-5.0:1)Ultra Long Zoom LNS-T51 Lens (4.8-8.0:1)“?” [CR]9.11.13 CR_COLWHEELTYPE CommandCommandDetailsResponse“CR_COLWHEELTYPE”[CR]Get which type of Color wheel is currently installedAcceptable%1Unacceptable“000_%1” [CR]“BRIGHTNESS” --- Color wheel for brightness is installed“COLREPRO” --- Color wheel for color reproduction is installed“?” [CR]DHD800 RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)99/101

PDG-DHT8000L Expand Serial Command Functional Specifications10. Command with Address Specification10.1. Overview- Commands with address are used to remote control more than one projector through RS-232C bya computer.- The command with address is defined as a single command per line that starts with “A” and endswith carriage return (0x0D).- When a projector receives carriage return (0x0D), it starts decoding.- The address such as “A001” is prefixed to the Basic Serial Command or Expand Serial Commandalready mentioned.e.g.) Functional Execution Command: “A001C05” [CR]e.g.) Status Read Command: “A001CR0” [CR]- Projector has the function to set up its own address in Service mode.Initial setting value is “No.001”Available range of the value is “001” to “999”- It clears the data in the receive buffer in the following cases.・ When receiving LF (0x0A) or EOF (0x1A)・ When it takes more than one second to receive a single command.(Until receiving carriage return after the reception of the first data)- It returns the response within 60ms.10.2. Functional Execution Command with address10.2.1. Format1) PC issues a command in the format below:“A” Address “C” Command [CR]or“A” Address “CF_” Command “_” Parameter [CR]Address: 3-digit number (”001” – “999”)Commands with “FFF” as the address are valid to all projectors.Command: string (Refer to Basic and Expand Serial Command)2) The only projector with the appropriate address decodes the received command, andwhen it is ready to receive the next command, it returns the response.[ACK] [CR]: When receiving Functional Execution Command (0x06, 0x0D)“ – “ [CR]: When the received data cannot be decodedHowever, when the address is “FFF”, the projector executes the function but does notreturn the response.DHD800 RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)100/101

PDG-DHT8000L Expand <strong>Serial</strong> Command Functional Specifications10. Command with Address Specification10.1. Overview- Commands with address are used to remote control more than one projector through RS-232C bya computer.- The command with address is defined as a single command per line that starts with “A” and endswith carriage return (0x0D).- When a projector receives carriage return (0x0D), it starts decoding.- The address such as “A001” is prefixed to the Basic <strong>Serial</strong> Command or Expand <strong>Serial</strong> Commandalready mentioned.e.g.) Functional Execution Command: “A001C05” [CR]e.g.) Status Read Command: “A001CR0” [CR]- Projector has the function to set up its own address in Service mode.Initial setting value is “No.001”Available range of the value is “001” to “999”- It clears the data in the receive buffer in the following cases.・ When receiving LF (0x0A) or EOF (0x1A)・ When it takes more than one second to receive a single command.(Until receiving carriage return after the reception of the first data)- It returns the response within 60ms.10.2. Functional Execution Command with address10.2.1. Format1) PC issues a command in the format below:“A” Address “C” Command [CR]or“A” Address “CF_” Command “_” Parameter [CR]Address: 3-digit number (”001” – “999”)Commands with “FFF” as the address are valid to all projectors.Command: string (Refer to Basic and Expand <strong>Serial</strong> Command)2) The only projector with the appropriate address decodes the received command, andwhen it is ready to receive the next command, it returns the response.[ACK] [CR]: When receiving Functional Execution Command (0x06, 0x0D)“ – “ [CR]: When the received data cannot be decodedHowever, when the address is “FFF”, the projector executes the function but does notreturn the response.<strong>DHD800</strong> RS232 Codes-Expand Technical Ref.020-000582-01 Rev. 1 (11-2012)100/101

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!