“RB Hub”Rainproof Bolt-On Hubs – For Use On NEMA Type 3R EnclosuresConduitSizeHeavy Duty Safety SwitchesAccessoriesClass 31103⁄4 1 1 1 ⁄4 1 1 ⁄2 2 2 1 ⁄2 3 3 1 ⁄2 4ClosingCapBoxCouplingHub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP BC200Price Each(DE1A)c$22.20 $22.20 $22.20 $22.20 $40.90 $68.00 $124.00 $190.00 $233.00 $2.40 $22.30uNEMA Type 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory installed. Order bolt-on hubs separatelyfrom table above. For more details see page 1-14. Hubs thru size 2 1 ⁄2 can be directly installed on RB devices. Devices requiring 3" or larger hubs musthave holes cut in <strong>the</strong> field. Gaskets are provided on 3" and larger hubs.All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.Watertight Hubs – For Use On NEMA Type 4, 4X and 5 Stainless Steel and Type 12 EnclosuresConduit Trade Size 1⁄23⁄4 1 1 1 ⁄4 1 1 ⁄2 2 2 1 ⁄2 3 3 1 ⁄2 4Standard-ZincHub <strong>Catalog</strong> NumberH050 H075 H100 H125 H150 H200 H250 H300 H350 H400Zinc Price Each $19.70 $28.60 $29.90 $34.30 $52.00 $76.00 $ 88.00 $112.00 $179.00 $242.00Chrome PlatedHub <strong>Catalog</strong> NumberH050CP H075CP H100CP H125CP H150CP H200CP H250CP H300CP H350CP H400CPChrome Plated Price Each 25.80 35.80 40.90 42.50 61.00 87.00 117.00 154.00 226.00 259.00<strong>Electrical</strong> Interlock Kits<strong>Electrical</strong> interlocks for heavy duty 30-1200 Ampere safety switches areavailable factory installed or in kit form for field installation. Each kitcontains instructions for proper field mounting. A pivot arm operatesfrom switch mechanism, breaking <strong>the</strong> control circuit before <strong>the</strong> mainswitch blades break. Switches with electrical interlocks installed are ULListed. For factory installed electrical interlocks add EI (for one contact)or EI2 (for two contacts) suffix to catalog number. Shipment 3 weeks.<strong>Electrical</strong> Interlock KitqSwitchAmpere Rating3060SeriesNumberE1F1F3E1F1-F3, F5F4100-200 E1-E2100 F2-F5400-1200 E2-E4<strong>Electrical</strong> Interlock Kit<strong>Catalog</strong> NumberaEK3001kEK3002kEIK031EIK032EIK1EIK2EK3061EK3062EIK1EIK2EIK031fEIK032fEK10201EK10202EIK1EIK2EIK40601EIK40602PriceFactory InstalledPrice$138. $228.138. 228.197. 287.138. 228.197. 287.138. 228.231. 321.197. 287.338. 428.q See page 3-7 for electrical interlocks on NEMA Type 4X Fiberglass Reinforced Polyester andKRYDON.a <strong>Electrical</strong> interlock kit catalog numbers with 1 suffix indicates one normally open and onenormally closed contact; 2 indicates two normally open and two normally closed contacts. Kitsare UL Listed.f H362WA, HU362WA, H362WC, H362AWA, HU362AWA, H362AWC and HU362AWC useEIK1 or EIK2 electric interlock.k HU461AWK, HU461DS Series E1 uses EK3061 or EK3062.<strong>Electrical</strong> Interlock Contact RatingsfAC - 50 or 60 HzInterlockType Volts Make Break Cont. Volts<strong>Catalog</strong> numbers ending with a 1 utilize a 9007A01 limit switch.1 NO/1 NCCONTACTDCMake &BreakCont.120 40 A 15 A 15 A 115 .50 A 15 A240 20 A 10 A 15 A 230 .25 A 15 A480 10 A 6 A 15 A – – –600 8 A 5 A 15 A 600 .05 A 15 A<strong>Catalog</strong> numbers ending with a 2 utilize a 9007C03 limit switch.120 30 A 3.0 A 10 A 115 1.0 A 10 A2 NO/2 NC 240 15 A 1.5 A 10 A 230 .30 A 10 ACONTACTS 480 7.5 A .75 A 10 A – – –600 6.0 A .60 A 10 A 600 .10 A 10 Af Single pole single throw interlock kits are rated 1 ⁄2 HP @ 110 and 220 Vac.Class R Fuse KitsWhen installed, this kit rejects all but Class R fuses. Kits are available forfield installation. For factory installation, add “CLR’’ suffix to catalognumber.Class R Fuse Kits – 240 Volt (one kit per 3-Pole switch)Switch AmpereRatingSeriesNumberClass R Fuse Kit<strong>Catalog</strong> NumberPriceFactory InstalledPrice30 E1 HRK30l $16.20 $124.0030 F1 RFK03L 16.20 124.0060 E1 HRK60 16.20 124.0060 F1, F2, F3, F5 RFK06 16.20 124.0060 F4 RFK03L 16.20 124.00100-200 E HRK1020 30.30 147.00100 F2-F5 RFK10 30.30 147.00400-600 E HRK4060 70.00 229.00l H221-2AWK uses QMB-30R Class R fuse kit, $29.70Class R Fuse Kits – 600 Volt (one kit per 3-Pole switch)Switch AmpereRatingSeriesNumberClass R Fuse Kit<strong>Catalog</strong> NumberPriceFactory InstalledPrice30k E1 HRK30Hs $16.20 $124.0030k F1 RFK03H 16.20 124.0030k F3 RFK06 16.20 124.0060k E1 HRK60H 16.20 124.0060k F1, F2, F3, F5 RFK06H 16.20 124.0060jk F4j RFK03Hj 16.20 124.00100-200k E1-E2 HRK1020 30.30 147.00100k F2-F5 RFK10 30.30 147.00400-600 E2-E4 HRK4060 70.00 229.00k See page 3-7 for Class R Fuse Kits in NEMA Type 4X Fiberglass Reinforced Polyester andKRYDON switches.s H361-2, AWK requires HRK-60 Class R fuse kit. Price $16.20j H362WA, H362WC, H362AWA, H362AWC, H362WH and H362AWH use RFK06H Class Rfuse kit.Fuse Puller KitsKit consists of three fuse pullers as required for a 3-Pole, fusible, 240 Vor 600 V heavy duty switch. Kits can be installed in switchesmanufactured after February, 1980. Fuse pullers supplied as standardequipment on NEMA Type 12, 12K, NEMA Type 4, 4X, 5 stainless steel,NEMA Type 4X Fiberglass Reinforced Polyester and KRYDON switchesthrough 100 Ampere.Switch AmpereRatingSeries NumberFuse Puller Kit<strong>Catalog</strong> NumberPrice30 E1 H30FP $19.1030 F1 FPK03 19.1030 F3 FPK0610 27.0060 E1 H60FP 22.2060 F1, F2, F3, F5 FPK0610 27.0060h F4h FPK03h 19.10100 E1-E2 H100FP 27.00100 F2-F5 FPK0610 27.00h H362WA, H362WC, H362AWA, H362AWC, H362WH and H362AWH use FPK0610 FusePuller Kit.SAFETY SWITCHES3For additional information, reference Enclosed Safety Switches <strong>Catalog</strong> 3100CT9801.KRYDON is a Registered Trademark of Crouse-Hinds Co.3/00DE1 cDE1A uPE9DiscountSchedule© 2000 Square DAll Rights Reserved3-9


Combination Service Entrance DevicesCircuit Breakers, AccessoriesClass 4119/4120LOAD CENTERS1Circuit BreakersFor use with Meter Mains and All-In-One devicesAmpereRatingcType: HOM, 1-Pole Type: HOM, 2-Pole Type: QO, 1-Pole Type: QO, 2-Pole Type: QO-VH, 1-Pole Type: QO-VH, 2-Pole<strong>Catalog</strong>NumberPrice(DE3D)<strong>Catalog</strong>NumberPrice(DE3D)<strong>Catalog</strong>NumberPrice(DE2A)<strong>Catalog</strong>NumberPrice(DE2A)<strong>Catalog</strong>NumberPrice(DE2A)<strong>Catalog</strong>Number10 . . . . . . . . . . . . QO110 $19.40 . . . . . . . . . . . . . . . . . .15 HOM115 $17.50 . . . . . . QO115 19.40 . . . . . . QO115VH $40.30 . . . . . .20 HOM120 17.50 . . . . . . QO120 19.40 . . . . . . QO120VH 40.30 . . . . . .25 HOM125 17.50 . . . . . . QO125 19.40 . . . . . . QO125VH 46.20 . . . . . .30 HOM130 17.50 HOM230 $ 40.30 QO130 19.40 QO230 $ 44.70 QO130VH 46.20 QO230VH $ 92.0035 . . . . . . HOM235 40.30 QO135 19.40 QO235 44.70 . . . . . . . . . . . .40 HOM140 17.50 HOM240 40.30 QO140 19.40 QO240 44.70 . . . . . . QO240VH 92.0045 . . . . . . HOM245 40.30 QO145 19.40 QO245 44.70 . . . . . . . . . . . .50 HOM150 17.50 HOM250 40.30 QO150 19.40 QO250 44.70 . . . . . . QO250VH 92.0060 . . . . . . HOM260 40.30 QO160 19.40 QO260 44.70 . . . . . . QO260VH 92.0070 . . . . . . HOM270 82.00 QO170 44.70 QO270 89.00 . . . . . . QO270VH 142.0080 . . . . . . HOM280 112.00 . . . . . . QO280 126.00 . . . . . . QO280VH 200.0090 . . . . . . HOM290 112.00 . . . . . . QO290 126.00 . . . . . . QO290VH 200.00100 . . . . . . HOM2100 112.00 . . . . . . QO2100 126.00 . . . . . . QO2100VH 200.00AmpereType: QOM1-VH, 2-Pole Type: QOM2-VH, 2-Pole Type: Q2L-H, 2-PoleRatingc <strong>Catalog</strong> Number Price (DE3A) <strong>Catalog</strong> Number Price (DE3A) <strong>Catalog</strong> Number Price (DE2A)50 QOM50VHq $ 89.00 . . . . . . . . . . . .60 QOM60VH 89.00 . . . . . . . . . . . .70 QOM70VH 89.00 . . . . . . . . . . . .80 QOM80VH 128.00 . . . . . . . . . . . .90 QOM90VH 128.00 . . . . . . . . . . . .100 QOM100VH 128.00 QOM2100VH $297.00 Q2L2100H $726.00110 QOM110VH 297.00 . . . . . . Q2L2110H 726.00125 QOM125VH 297.00 QOM2125VH 297.00 Q2L2125H 726.00150 . . . . . . QOM2150VH 297.00 Q2L2150H 726.00175 . . . . . . QOM2175VH 297.00 Q2L2175H 726.00200 . . . . . . QOM2200VH 297.00 Q2L2200H 726.00225 . . . . . . QOM2225VH 297.00 . . . . . .Price(DE2A)c Do not exceed mains rating of deviceq Reference National <strong>Electrical</strong> Code Article 230-79.AccessoriesDescriptionGenerator Kit: Interlocks main service disconnect andgenerator circuit breaker (order separately). For use on:HOMELINE CSED DevicesRC816F-, RC2040M-QO CSED DevicesQC816F-, QC2040M-p Order only. Not stocked in PDS. Order Point: Lexington.<strong>Catalog</strong>NumberRCGK2QCGK2PriceDisc.Sch.$148.00(DE3A)148.00Fifth Jaw Kit for:Meter Main Types: C, RC, SC, QC5J11.60 (DE3A)All-In-One Types: SC, SU (100-225A), QC, RCFifth Jaw Kit (9:00 position) for: CU12L400L,SU3040D300L, and SU3040D400L35815SPL 38.50 (DE3A)Bypass (Horn Type) for:Ringless Type Meter Mains and All-In-Ones (100-200 A)RCHB2 58.00 (DE3A)Lexan Meter Socket Cover Plate for:Ring and Ringless Type Meter MainsRing and Ringless Type All-In-Ones29007 6.40 (DE4)Meter Socket Sealing Rings for Ring TypeMeter Mains and All-In Ones:Screw Type AluminumSnap Type Stainless SteelLatch Type Stainless SteelTrim Kit for 2" X 6" stud wall, used with:REVERSE All-In-Ones, SU3040M200R, andSU3040M225RBarrel Lock Kit (Barrel Lock not included),supplied with bracket and mounting screw,refer to listings for where used.Semiflush Flange Kit for:Ring Type Convertible Surface/SemiflushMeter Mains (125-200 A)All-In-Ones (125-200 A)Ringless Type Convertible Surface/SemiflushMeter Mains (125-200 A)Semiflush Flange Kit for:Ring Type Convertible Su rface/SemiflushMeter Mains (300-400 A)All-In-Ones (300-400 A)Ringless Type Convertible Surface/SemiflushAll-In-Ones (300-400 A)Ringless Type Utility Cover for use on:SU3040D300L, SU3040D400L, and CU12L400L.Includes one piece meter socket and pull box coverwith handles and closing plate.Lug Kit includes (4) lugs, for use with#2 AWG-600 kcmil Al/Cu conductors. Lugs are forstandard 2-Hole mounting. Meter Main and All-In-Oneunits supplied with (2) Studs per phase and neutral willaccept one lug per phase and neutral29008W29209-100-02p29008GSU2X6TRIMSCBRLLOCKSC200FSU400FC400LCMELK412.8010.6012.80(DE4)161.00 (DE3A)32.10 (DE3A)19.30 (DE3A)119.00 (DE3A)161.00 (DE3A)87.00 (DE4A)AccessoriesHubs and Closing PlatesHubSeriesDescriptionConduit Size(inches)b Supplied with AAP adapter plate and “A” hub<strong>Catalog</strong>Number<strong>Catalog</strong>NumberPriceListPriceDisc.Sch.Touch-Up Paint(ASA49 Gray) PK49SP $24.80 (DE1)Ground Bar KitQC, SC, RC, and SU (100-225 A)SC3040M200RS and SC40M200SFiller Plate for:Meter Main Types: QC, CUAll-In-One Types: QCFiller Plate for:Meter Main Types: RC, SCAll-In-One Types: SC, RC, SUNeutral Lug (#6-2/0) for:Meter Main Types: RC, SC, QCAll-In-One Types: SC, SU, QC, RCPK15GTAPK23GTAQOFPHOMFPLK100AN10.9013.50 (DE3A)(DE3A)2.30 (DE3A)2.00 (DE3A)6.90 (DE3A)Disc.Sch.Closing Plate for “A” Hub opening ACP $ 8.50 (DE4)1.00 A100 21.50 (DE4)1.25 A125 21.50 (DE4)A1.50 A150 21.50 (DE4)2.00 A200 30.40 (DE4)2.50 A250 38.50 (DE4)Adapter plate to allow use of “A” Hubson “A-L” size hub openingsAAP 21.40 (DE4)Closing Plate for “A-L” Hub opening ACPL 11.60 (DE4)2.00 A200L b 52.00 (DE4)2.50 Order A250 + AAP . . . . . .A-L3.00 A300L 70.00 (DE4)3.50 A350L 72.00 (DE4)4.00 A400L 75.00 (DE4)Closing Plate for “B” Hub opening BCAP 2.40 (DE1A)0.75 B075 22.20 (DE1A)1.00 B100 22.20 (DE1A)B1.25 B125 22.20 (DE1A)1.50 B150 22.20 (DE1A)2.00 B200 40.90 (DE1A)2.50 B250 68.00 (DE1A)B300 3.00 B300 124.00 (DE1A)© 2000 Square D All Rights Reserved1-18DE1 DE1A DE2A DE3A DE3D DE4 DE4ADiscountSchedule 3/00


Heavy Duty Safety Switches240 VoltClass 3110SAFETY SWITCHES3Visible blade Heavy Duty Safety Switches are designed for applicationwhere maximum performance and continuity of service are required. AllHeavy Duty Safety Switches feature quick-make, quick-break operatingmechanism, a dual cover interlock and a color coded indicator handle.They are suitable for use as service equipment when equipped with a fieldor factory installed neutral assembly or equipment grounding kit, unless a600Y/347 V or 480 Y/277 V, 1000 Amp or greater, solidly grounded WYEsystem is used, per NEC 215-10. Heavy duty safety switches are ULListed (except as noted), File E2875 & 154828 and meet or exceed <strong>the</strong>NEMA Standard KS1. NEMA Type 12, 12K and stainless steel switchesthrough 200 Ampere are UL Marine Listed for use on vessels over 65 feetlong. For UL Listed short circuit withstand ratings, see page 3-6.240 Volt – Single Throw FusibleSystemAmpsNEMAType 1IndoorNEMAType 3RRainproof(Bolt-on Hubspage 3-9)NEMA Type 4, 4X, 5,(304 Stainless Steel)Dusttight, Watertight,Corrosion ResistantAll Cu CurrentCarrying Parts(Watertight Hubspage 3-9)NEMA Type 1 NEMA Type 3R NEMA Type 4, 4X and 5 NEMA Type 12Stainless SteelJIC-Mill & Foundry TypeAll Cu Current Carrying Parts(Watertight Hubs-page 3-9)NEMA Type 12KWithKnockoutsNEMA Type 12, 3RjWithoutKnockoutsHorsepower RatingspCat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 1Ø 3Ø 1Ø 3Ø2 Wire (2 Blades and Fuseholders) – 240 Vac, 250 Vdc30H221DS $ 1236. H221A $ 320. H221AWK $ 300. 1 1 ⁄2 – 3 – 530 Use 3 Wire Devices– – – – H2212AWKq 373. 1 1 ⁄2 – 3 – 560 For 2 Wire ApplicationsH222DS 1484. H222A – H222AWK 410. 3 7 1 ⁄2f 10 15 f 10100 H223DS 3234. H223A 640. H223AWK 602. 7 1 ⁄2 15 f 15 30 f 20200 H224DS 4419. H224A 1103. H224AWK 1043. 15 – – – 40400 H225 $1819. H225R $ 2589. H225DS 9194. – – H225AWK 2643. – – – – 50600 H226 3616. H226R 4854. H226DS 13189. – – H226AWK 4154. – 75 f – 200 f –800 H227 5639. H227Rb 7655. – – – – H227AWK 6555. 50 – 50 – 501200 H228 7788. H228Rb 10324. – – – – H228AWK 10041. 50 – 50 – 503 Wire (2 Blades and Fuseholders, 1 Neutral) – 240 Vac, 250 Vdc30 H221N $157. H221NRB $ 298. Use 2 Wire Devices,1 1 ⁄2 3 f 3 7 1 ⁄2f 560 H222N 314. H222NRB 561. Field Installable Solid Neutral Assemblies3 7 1 ⁄2f 10 15 f 10100 H223N 477. H223NRB 724. Order Separately See page 3-107 1 ⁄2 15 f 15 30 f 20200 H224N 859. H224NRB 1041. 15 25 f – 60 f 40400 H225N 2061. H225NR 2830. H225NDS $ 9389. – – H225NAWK $ 2732. – 50 f – 125 f –600 H226N 3879. H226NR 5118. H226NDS 13385. – – H226NAWK 4404. – 75 f – 200 f –800 H227N 6711. H227NRb 8144. – – – – H227NAWK 7833. 50 – 50 – 501200 H228N 8281. H228NRb 11110. – – – – H228NAWK 10910. 50 – 50 – 503 Wire (3 Blades and Fuseholders) – 240 Vac, 250 Vdc30H321DS $ 1301. H321A $ 406. H321AWK $ 384. – 3 – 7Use 4 Wire Devices⁄2 560 H322DS 1608. H322A 580. H322AWK 549. 3 7For 3 Wire Applications⁄2f 10 15 f 10100 H323DS 3394. H323A 896. H323AWK 845. 7 1 ⁄2 15 f 15 30 f 20200 H324DS 4759. H324A 1295. H324AWK 1223. – 25 – 60 40400 H325 $2283. H325R $ 2650. H325DS 9499. – – H325AWK 2700. – 50 – 125 50600 H326k 4113. H326Rk 5524. H326DSk 13587. – – H326AWKk 4676. – 75 – 200 –800 H327 7637. H327Rb 9899. – – – – H327AWK 9224. 50 100 50 250 501200 H328 9678. H328Rb 12485. – – – – H328AWK 11079. 50 100 50 250 504 Wire (3 Blades and Fuseholders, 1 Neutral) – 240 Vac, 250 Vdc30 H321N $209. H321NRB $ 370. Use 3 Wire Devices,1 1 ⁄2 3 3 7 1 ⁄2 560 H322N 352. H322NRB 594. Field Installable Solid Neutral Assemblies3 7 1 ⁄2 10 15 10100 H323N 561. H323NRB 852. Order Separately See page 3-107 1 ⁄2 15 15 30 20200 H324N 967. H324NRB 1165. – 25 – 60 40400 H325N 2525. H325NR 2881. H325NDS $ 9728. – – H325NAWK $ 2943. – 50 – 125 50600 H326N 4346. H326NR 5748. H326NDS 13815. – – H326NAWK 4925. – 75 – 200 –800 H327N 8126. H327NRb 10375. – – – – H327NAWK 10082. 50 100 50 250 501200 H328N 10209. H328NRb 13139. – – – – H328NAWK 12708. 50 100 50 250 504 Wire (4 Blades and Fuseholders)3060100200Use 600 Vac Devices See page 3-5.400600p Refer to page 5-13 for additional motor application data. The starting current of motors of more than standard horsepower may require <strong>the</strong> use of fuses with appropriate time delay characteristics.j Also suitable for NEMA Type 3R application by removing drain screw from bottom endwall.f For grounded “B’’ phase systems only and with neutral assembly installed.q 60 Ampere switch with 30 Ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks.b Suitable for NEMA Type 5 applications with drain screw installed.k No dc rating.Std.240 VacMax.250VdcNOTE: One day shipment is available on DASH program for non-stock 400 through 1200 Ampere heavy duty switches.Dimensions NEMA Type 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3-12NEMA Type 4, 4X and 5 Stainless and NEMA Type 12 . . . . . . . . Page 3-13Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 3-9 through 3-11For additional information, reference <strong>the</strong> Enclosed Safety Switches <strong>Catalog</strong> 3100CT9801.3-4© 2000 Square DAll Rights ReservedDE1DiscountSchedule3/00


Heavy Duty Safety Switches600 VoltClass 3110Class H Fuse Provisions:Fusible Square D 30 through 600 Ampere Heavy Duty Safety Switchesaccept Class H fuses as standard. With Class H fuses installed <strong>the</strong>switch is UL Listed for use on systems with up to 10,000 RMSSymmetrical Amperes available fault current.Class R Fuse Provisions:Fusible Square D 30 through 600 Ampere HeavyDuty Safety Switches will accept Class R fusesas standard. A field installable rejection kit isavailable which, when installed, rejects all butClass R fuses. With <strong>the</strong> installation of <strong>the</strong>rejection kit and Class R fuses, <strong>the</strong> switch is ULListed for use on systems with up to 200,000RMS Symmetrical Amperes available faultcurrent. See Class R Fuse Kits on page 3-9.Class J Fuse Provisions:Provisions for installing Class J fuses are included in 30 through 400Ampere 600 Volt, and 100 through 400 Ampere 240 Volt, fusible HeavyDuty Safety Switches. Conversion to Class J fuse spacing requiresrelocating <strong>the</strong> load side fuse base assembly from <strong>the</strong> standard Class Hfuse location to an alternate position as marked in <strong>the</strong> enclosure. WithClass J fuses installed, <strong>the</strong> switch is UL Listed for use on systems withup to 200,000 RMS Symmetrical Amperes available fault current.Switches rated 600 Amperes, 240 or 600 Volt, require <strong>the</strong> addition of anadapter kit, H600J at $304. One kit per 3-pole switch.Class L Fuse Provisions:Fusible 800 A and 1200 A Safety Switches use Class L bolt-in fuses andare rated for use on systems with up to 200,000 RMS SymmetricalAmperes at 600 Vac maximum.600 Volts – Single Throw FusibleSystemAmpsNEMAType 1IndoorNEMAType 3RRainproof(Bolt-on Hubspage 3-9)NEMA Type 4, 4X, 5(304 Stainless Steel)Dusttight, Watertight,Corrosion ResistantAll Cu CurrentCarrying Parts(Watertight Hubspage 3-9)JIC-Mill & Foundry TypeAll Cu CurrentCarrying Parts(Watertight Hubs-page 3-9)NEMA Type 12KWith KnockoutsNEMA Type 12, 3RjWithout KnockoutsHorsepower Ratingsp480 Vac 600 VacStd. Max. Std. Max.Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price 3Ø 3Ø 3Ø 3Ø 250 6002 Wire (2 Blades and Fuseholders) – 600 Vac, 600 Vdc30– – – – – –60 Use 3 Wire Devices– – – – – –100 For 2 Wire Applications– – – – – –200 – – – – – –400 H265 $ 2804. H265R $ 3616. H265DS $ 9499. – – H265AWK $ 3190. 100 f 250f – – 50 –600 H266 4435. H266R 7124. H266DS 13587. – – H266AWK 4747. 150 f 400f – – – –800 H267 6910. H267Rb 10923. – – – – H267AWK 9699. – – – – 50 501200 H268 9713. H268Rb 11994. – – – – H268AWK 11456. – – – – 50 503 Wire (3 Blades and Fuseholders) – 600 Vac, 600 Vdckd30 H361 $ 352. H361RB $ 599. H361DS $ 1600. H361A $ 644. H361AWK $ 607. 5 15 7 1 ⁄2 20 – 1530 H361-2q 411. H3612RBq 699. – – H361-2Aq 657. H3612AWK q 620. 5 15 7 1 ⁄2 20 – 1560 H362 425. H362RB 703. H362DS 1759. H362A 665. H362AWK 625. 15 30 15 50 – 30100 H363 792. H363RB 1096. H363DSc 3488. H363A 1032. H363AWK 977. 25 60 30 75 – 40200 H364 1138. H364RB 1506. H364DS 4879. H364A 1615. H364AWK 1524. 50 125 60 150 – 50400 H365 3034. H365R 3688. H365DS 9728. – – H365AWK 3468. 100 250 125 350 50 –600 H366 5099. H366R 7266. H366DS 13815. – – H366AWK 5843. 150 400 200 500 – –800 H367 8879. H367Ra 11000. – – – – H367AWK 10382. 200 500 250 500 50 501200 H368 11671. H368Ra 13339. – – – – H368AWK 12511. 200 500 250 500 50 504 Wire (3 Blades and Fuseholders, 1 Neutral) – 600 Vac30 H361N $ 411. H361NRB $ 657. Use 3 Wire Devices Field Installable Solid Neutral5 15 7 1 ⁄2 20 – 1560 H362N 473. H362NRB 756. Assemblies. Order Separately-See page 3-1015 30 15 50 – –100 H363N 852. H363NRB 1158. 25 60 30 75 – –200 H364N 1246. H364NRB 1605. H364NDS $ 4997. H364NA $ 1724. H364NAWK $ 1624. 50 125 60 150 – 50400 H365N 3265. H365NR 3843. H365NDS 9948. – – H365NAWK 3697. 100 250 125 350 – –600 H366N 5346. H366NR 7369. H366NDS 14046. – – H366NAWK 6095. 150 400 200 500 – –800 H367N 9362. H367NRa 11470. – – – – H367NAWK 10954. 200 500 250 500 50 501200 H368N 12076. H368NRa 13995. – – – – H368NAWK 13219. 200 500 250 500 50 504 Wire (4 Blades and Fuseholders) – 600 Vach 2Ø 2Ø 2Ø 2Ø30 H461 $ 580. – – H461-2DSqs $ 1865. – – H461AWK $ 708. 7 1 ⁄2 20 10 25 5b 15b60 H462 676. – – H462DSs 1949. – – H462AWK 798. 15 40 20 50 10b 30b100 H463 1129. – – H463DSs 5298. – – H463AWK 1227. 25 50 30 75 25b 30b200 H464 1877. – – H464DSs 7997. – – H464AWK 2046. 50 50 50 50 – –400 H465 3943. – – – – – – H465AWK 4322. – – – – – –600 H466 6415. – – – – – – – – – – – – – –6 Wire (6 Blades and Fuseholders) – 600 VachdcSAFETY SWITCHES3100 – – – – H663DSs $16485. – – H663AWK $ 3246. For applications requiring motor disconnectcapability, use electrical interlock.200 – – – – H664DSs 22471. – – H664RWKs 7760.Refer to page 3-9.p Refer to page 5-13 for additional motor application data. The starting current of motors of more than standard horsepower may require <strong>the</strong> use of fuses with appropriate time delay characteristics.j Also suitable for NEMA Type 3R application by removing drain screw from bottom endwall.c 250 Vdc maximum. Use two outside poles for switching DC.f For grounded “B’’ phase systems only and with neutral assembly installed.a Suitable for NEMA Type 5 applications with drain screw installed.k On 3-Pole devices, use two outside poles for switching DC.q 60 Ampere switch with 30 Ampere fuse spacing and clips. Must use 60 A enclosure accessories including electrical interlocks.h Not suitable for use as service equipment.s Not UL Listed – 6 week shipment.d 400 and 600 Amp – 600 Vac only.b Does not apply to NEMA Type 4, 4X and 5 switches.NOTE: One day shipment is available on DASH Program for non-stock 400 through 1200 Ampere heavy duty switches.Dimensions NEMA Type 1 and 3R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3-12NEMA Type 4, 4X and 5 Stainless and NEMA Type 12 . . . . . . Page 3-13Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 3-9 and 3-11For additional information, reference <strong>the</strong> Enclosed Safety Switches <strong>Catalog</strong> 3100CT9801.3/00DE1DiscountSchedule© 2000 Square DAll Rights Reserved3-5