UNITEDPOWERSeries MC: <strong>Power</strong> Distribution Modulesfor Mission Critical Applications


Series MC PDMsComplete Your <strong>Power</strong> System Design WithMission Critical Series <strong>Power</strong> Distribution ModulesUnited <strong>Power</strong>’s Mission Critical <strong>Power</strong>Distribution Modules (PDMs) allow you toextend the redundancy of your criticalpower system from the service entranceto the output distribution circuits feed<strong>in</strong>gyour critical load. By extend<strong>in</strong>g your system’sredundancy, Series MC PDMsensure that you receive maximum benefitfrom the <strong>in</strong>vestment you already have<strong>in</strong> your critical power system. Dual utilityfeeds, redundant back-up eng<strong>in</strong>e generatorsand sophisticated UPS systems shouldfeed a power distribution unit that<strong>in</strong>creases the system’s overall reliabilityand flexibility.Until now, virtually all computer powerdistribution units featured a s<strong>in</strong>gle ma<strong>in</strong>circuit breaker and one high isolationtransformer feed<strong>in</strong>g multiple panelboardsfor distribution of the protected power tothe critical loads. However, Series MCPDMs br<strong>in</strong>g redundancy to the po<strong>in</strong>t ofuse level by <strong>in</strong>troduc<strong>in</strong>g dual <strong>in</strong>put circuitbreakers, dual transformers and astatic transfer switch, depend<strong>in</strong>g on theSeries MC platform you choose.Series MC distribution units are customeng<strong>in</strong>eeredto maximize the strengths ofyour entire critical power system. Weoffer four basic pre-eng<strong>in</strong>eered “platforms,”each of which may be custom-tailoredto meet the requirements of yourspecific application.SOURCE ASOURCE BEQUIPMENTROOMSWITCHGEARINPUTCBCOMPUTERROOMSTANDARD PDMTRANSFORMERPANELBOARDSTO CRITICAL LOADIn the past, system redundancy often stopped before the power distribution unit. Eachload was fed from a PDM with a s<strong>in</strong>gle <strong>in</strong>put breaker and a s<strong>in</strong>gle high isolation transformer.EQUIPMENTROOMSOURCE ASOURCE BINPUTCB 1INPUTCB 2COMPUTERROOMMISSION CRITICAL PDMTRANSFORMER1TRANSFORMER2STATICTRANSFERSWITCHPANELBOARDSTO CRITICAL LOADNow, the Series MC PDM br<strong>in</strong>gs system redundancy to the po<strong>in</strong>t of use level by <strong>in</strong>troduc<strong>in</strong>gdual <strong>in</strong>put circuit breakers, dual transformers and static transfer switches.Series MC PDMs complement your power system design,allow<strong>in</strong>g you to:• Improve power reliability— Superior designs and quality components• Improve power availability— Redundancy for maximum protection• Improve system ma<strong>in</strong>ta<strong>in</strong>ability— Rout<strong>in</strong>e service with no downtime requiredInnovation <strong>in</strong> design has made United <strong>Power</strong> atechnological leader <strong>in</strong> the critical power <strong>in</strong>dustry.Our Series MC PDMs are eng<strong>in</strong>eered to provideadvanced solutions for critical power environmentsby maximiz<strong>in</strong>g system reliability and allow<strong>in</strong>g systemma<strong>in</strong>tenance and repair without downtime.


Mission Critical <strong>Power</strong> Distribution Is TheInnovative Solution To Our Customers’ NeedsSeries MC PDMs were born <strong>in</strong> the search for anadvanced solution to a difficult problem. In a criticalpower environment, downtime can mean the loss ofthousands of dollars per second for your company. Inlisten<strong>in</strong>g to our customers, we heard consultants andfacility managers from such mission critical environmentsrepeat two major concerns:• How can we maximize reliability of our criticalpower system from the utility source to the load?• How can we ma<strong>in</strong>ta<strong>in</strong> and repair the entirecritical power system, <strong>in</strong>clud<strong>in</strong>g the PDM, withoutdowntime?Draw<strong>in</strong>g on our experience and knowledge <strong>in</strong> powerdistribution products, United <strong>Power</strong> comb<strong>in</strong>ed thelatest technology and <strong>in</strong>novative design strategies todevelop the Series MC PDMs. The result is anextremely flexible power distribution unit that can beeasily modified to work with any critical power system,regardless of configuration! Today, Series MCsystems are eng<strong>in</strong>eered to protect some of the mostprestigious sites <strong>in</strong> the country — from major f<strong>in</strong>ancialdata centers to high-tech manufactur<strong>in</strong>g processes.United <strong>Power</strong> Products Are Born Of ExperienceAnd InnovationUnited <strong>Power</strong> personnel have been design<strong>in</strong>g andmanufactur<strong>in</strong>g power condition<strong>in</strong>g and distributionequipment for critical power environments for nearly20 years. Our broad product l<strong>in</strong>e <strong>in</strong>cludes:• Dual Feed & Static Switch PDMs• <strong>Power</strong> Distribution <strong>Systems</strong>• UL Listed <strong>Power</strong> Distribution Cables• Transient Voltage Surge Suppression• K-Rated, Isolation & Phase ShiftTransformers• Rotary & Static <strong>Power</strong> Condition<strong>in</strong>g<strong>Systems</strong>• S<strong>in</strong>gle-Phase UPS (4-18 kVA)• S<strong>in</strong>gle-Phase Central Light<strong>in</strong>g InvertersMC-3 PDMUnited <strong>Power</strong> Series MC PDMs are custom-eng<strong>in</strong>eered to complement your criticalpower applications.United <strong>Power</strong>’s <strong>in</strong>novation <strong>in</strong> power equipmentdesign is recognized by a grow<strong>in</strong>gcustomer list of more than 3,000 corporate,<strong>in</strong>dustrial and government sites. Wehave the technology and experience necessaryto serve the most demand<strong>in</strong>g customerrequirements.Quality is a promise and a priority at United<strong>Power</strong>. Series MC PDMs are manufactured todemand<strong>in</strong>g quality control standards. In addition,all our products meet str<strong>in</strong>gent UL standards.Wepledge to provide every customer superior serviceand knowledgeable eng<strong>in</strong>eer<strong>in</strong>g support.


Series MC-1 and MC-2Series MC PDMs Offer Cost Effective Internal RedundancyAnd Make-Before-Break TransfersUnited <strong>Power</strong>’s MC-1 and MC-2 systems provide costeffectivesolutions to those Mission Critical applicationswhere the user wants to optimize power availabilityand system ma<strong>in</strong>ta<strong>in</strong>ability. A permissive signal fromthe upstream power sources verifies synchronizationand allows the user to <strong>in</strong>itiate a “make-before-break”transfer from one side of the system to the other. Thistransfer may be made by manual operation of the ma<strong>in</strong><strong>in</strong>put circuit breakers or through push-button controlswhen our automatic control configuration has beenselected. With either configuration, our advanced controllogic prevents the possibility of operator error. Themake-before-break transfer allows the user to performsystem ma<strong>in</strong>tenance without downtime to the criticalload. Redundant PDM <strong>in</strong>put circuit breakers andtransformers dramatically reduce recovery time <strong>in</strong>the event of an equipment failure (MC-2).MC-1 — Flexible System BypassUnited <strong>Power</strong> MC-1 systems are the first step <strong>in</strong> maximiz<strong>in</strong>gthe benefits of br<strong>in</strong>g<strong>in</strong>g redundancy <strong>in</strong>to thePDM. The MC-1 is the least expensive member of ourMission Critical PDM product l<strong>in</strong>e and provides theuser with a second ma<strong>in</strong> <strong>in</strong>put circuit breaker protectivedevice. This design is often used as an economicalma<strong>in</strong>tenance bypass to accommodate theoutput of one UPS and its synchronized bypasssource. This <strong>in</strong>tegrates the system bypass function<strong>in</strong>to the PDM rather than <strong>in</strong>to expensive externalbypass switchgear.MC-1 ma<strong>in</strong> <strong>in</strong>put breakers are electrically <strong>in</strong>terlocked forsafe manual operation. They may also be automaticallyoperated for those sites where push-button controlsare desired. All MC-1 systems feature the use of United<strong>Power</strong>’s advanced control logic to ensure properoperation of the two ma<strong>in</strong> <strong>in</strong>put circuit breakers.SERIES MC-1 PDMBYPASS FEEDCB2UPS BYPASSPERMISSIVESIGNAL FROM UPSCONTROLLOGICMC-1 PDMUPS INPUTUPSSYSTEMCB1MC PDMs improve system availabilityand ma<strong>in</strong>ta<strong>in</strong>abilityThe above one-l<strong>in</strong>e diagram illustrates an MC-1 PDM used for power distribution and UPSsystem bypass functions.Data process<strong>in</strong>g facilities know that loss ofpower means lost data that can result <strong>in</strong> the lossof millions of dollars per m<strong>in</strong>ute. United <strong>Power</strong>fully understands the complex requirements ofcritical power loads. We designed our Series MCPDMs to be the <strong>in</strong>telligent solution for provid<strong>in</strong>gthe most reliable and ma<strong>in</strong>ta<strong>in</strong>able power distributionsystem offered today.


MC-2 — Dual Transformers For MaximumProtection And Ma<strong>in</strong>ta<strong>in</strong>abilityUnited <strong>Power</strong> MC-2 systems extend the redundancy<strong>in</strong> your power distribution unit beyond the ma<strong>in</strong><strong>in</strong>put breakers by <strong>in</strong>clud<strong>in</strong>g a second impedancematchedtransformer for maximum ma<strong>in</strong>ta<strong>in</strong>abilityand protection aga<strong>in</strong>st potential s<strong>in</strong>gle po<strong>in</strong>ts of failure.The MC-2 load may be transferred from one side ofthe unit to the other <strong>in</strong> a “make-before-break” manner.This allows system ma<strong>in</strong>tenance without downtime,an essential feature of a mission critical site. To completethe design, all MC-2 systems <strong>in</strong>clude outputbreakers <strong>in</strong> our two-device, classic three-device “tie”,or our unique four-device “criss-cross” configuration.The MC-2 output breakers are available with eithermanual or automatic (push-button) operation basedon your personal preference. Simply provide United<strong>Power</strong> a permissive signal that confirms that the two<strong>in</strong>puts of the PDM are fed from synchronized sourcesand make-before-break operation is allowed. The controlswith<strong>in</strong> the MC-2 do the rest to ensure safe andreliable operation of this advanced distribution system.INPUTSOURCE BPERMISSIVESIGNAL(BY OTHERS)INPUTSOURCE ACB2CB1CONTROLLOGICOur MC-2 three breaker “tie” configuration allows you to place100% of the load onto either side of the PDM for system ma<strong>in</strong>tenancewithout downtime. Dur<strong>in</strong>g normal operation, each transformersupports no more than 50% of the load.CB4CB3CB5MC-1 and MC-2 FeaturesFeatureMC-1 MC-2System kVA Range75-300kVA S SSystem VoltagesInput: 480V 3 phase, Output: 208/120V 3 phase S SInput: 208V 3 phase, Output: 208/120V 3 phase O OOther <strong>in</strong>ternational voltage & frequency comb<strong>in</strong>ations O OLoad Transfer Control (select one below)Padlocks on breakers S N/AElectrically <strong>in</strong>terlocked breakers S SMotor operated breakers S SInput Circuit BreakersDual <strong>in</strong>put circuit breakers S SLightn<strong>in</strong>g Arrestor/Surge SuppressorHigh energy surge protection on the transformer primary O OIsolation TransformersK-13 rated S SK-20 rated O ODual impedance matched transformers N/A SHarmonic mitigat<strong>in</strong>g transformers O N/AOutput Circuit Breakers (select one below)Two breaker output bus N/A SThree “tie” breaker output bus N/A SFour “Criss Cross” breaker output bus N/A STransient Voltage Surge SuppressionOne stage (L-N) @ 80,000 Amps total O OTwo stage (L-N & N-G) @ 160,000 Amps total O OThree stage (L-N, N-G & L-G) @ 240,000 Amps total O OFocus Microprocessor Controlled Monitor<strong>in</strong>gTrue RMS voltage, current, kVA, demand, alarm<strong>in</strong>g, etc. S SThree phase sag/surge transient, THD monitor O ODistribution PanelboardsTwo through eight 42-pole panelboards available S S225 amp secondary ma<strong>in</strong> breaker feed<strong>in</strong>g each panelboard S SSubfeed Distribution BreakersUp to four 225A 3-pole breakers <strong>in</strong> lieu of a panelboard O OS = Standard O = Optional N/A = Not AvailableThe chart above illustrates standard and optional features of theMC-1 and MC-2 systems to help you determ<strong>in</strong>e which MissionCritical configuration most closely meets your requirements.The telecommunications <strong>in</strong>dustry is a missioncritical environment ensur<strong>in</strong>g cont<strong>in</strong>uous communicationthrough such facilities as remote cellularswitch<strong>in</strong>g stations and long distance call rout<strong>in</strong>gcenters. United <strong>Power</strong> Series MC PDMs extendthe redundancy of critical power systems <strong>in</strong> thetelecommunications <strong>in</strong>dustry, help<strong>in</strong>g to providethe cont<strong>in</strong>uous service expected and required.


Series MC-3 and MC-4Series MC PDMs Offer Static Transfer Switch TechnologyFor Transparent Switch<strong>in</strong>g Between SourcesThe MC-3 and MC-4 feature advanced static transferswitch (STS) technology complete with on-board diagnosticsthat monitor each of the two <strong>in</strong>put sources forany abnormal characteristics. In the event of a powerproblem, the STS provides the ability to transfer fromthe preferred power source to the alternate powersource with<strong>in</strong> four milliseconds (less than one-quartercycle). By <strong>in</strong>tegrat<strong>in</strong>g the ultra-fast STS <strong>in</strong>to the powerdistribution unit, we <strong>in</strong>crease the reliability and flexibilityof your entire critical power system. Other featuressuch as redundant circuit breakers and isolation transformershave made these systems the choice of missioncritical environments across the country.INPUTSOURCE BTRANSFERCONTROLLOGICMCS2MCS1SS2SS1MCS4MCS5PDMCONTROLLOGICCB1MC-3 — Input-Positioned STSINPUTSOURCE AMCS3Model MC-3 is the first “platform”with<strong>in</strong> the Mission Criticalproduct l<strong>in</strong>e to feature astatic transfer switch (STS).The 100% rated STS is positionedon the <strong>in</strong>put of thesystem’s isolation transformer.In popular 480 Vac <strong>in</strong>put,120/208 Vac output applications,we position the STSat a higher operat<strong>in</strong>g voltageto reduce the size and costassociated with the switch.Our “l<strong>in</strong>e up and match” cab<strong>in</strong>etryprovides a clean look forthe data center, clean room orother high-tech environment.Focus Level III microprocessormonitor<strong>in</strong>g is standard on allMC-3 units and a mimic panelis provided to show the criticalpower path of the system.United <strong>Power</strong> MC-3 systems feature an <strong>in</strong>put-positioned STS,provid<strong>in</strong>g 4mS switch<strong>in</strong>g between two different sources.A static transfer switch <strong>in</strong>tegrated <strong>in</strong>to the PDM <strong>in</strong>creases system reliability and flexibility.MC-4 PDMProcess control environments require missioncritical power distribution to ensure consistentperformance and accurate control <strong>in</strong> productionand manufactur<strong>in</strong>g. From process flow controlsto robotics, United <strong>Power</strong> MC PDMs provide bothreliable and ma<strong>in</strong>ta<strong>in</strong>able power distribution technologyfor today’s sophisticated manufactur<strong>in</strong>gprocesses.


MC-4 — Output-Positioned STS On DualTransformersUnited <strong>Power</strong>’s MC-4 is the ultimate power distributionsystem and is currently support<strong>in</strong>g some of thenation’s most critical data process<strong>in</strong>g facilities. In theMC-4, we have comb<strong>in</strong>ed the attributes of the STSwith dual high isolation transformers to optimize theredundant characteristics of the system. As a result,the MC-4 provides <strong>in</strong>creased reliability, ma<strong>in</strong>ta<strong>in</strong>ability,and availability of conditioned power for yourcritical load. Perhaps this is why so many of our customershave chosen this PDM configuration.The MC-4 boasts flexibility not found <strong>in</strong> other distributionsystems. For clients with a high concentrationof “dual corded” loads, we can feed “dual corded”loads directly from the output of the isolation transformersand feed “s<strong>in</strong>gle corded” loads from the STSoutput. This will typically reduce the necessaryampere rat<strong>in</strong>g of the STS while optimiz<strong>in</strong>g reliabilityand cost.INPUTSOURCE BINPUTSOURCE ACB2PDM BCONTROLLOGICPDM ACONTROLLOGICCB1TRANSFERCONTROLLOGICMCS2MCS1SS2SS1MCS4MCS5MCS3MC-3 and MC-4 FeaturesFeatureMC-3 MC-4System kVA Range75-300kVA S SSystem VoltagesInput: 480V 3 phase, Output: 208/120V 3 phase S SInput: 208V 3 phase, Output: 208/120V 3 phase O OOther <strong>in</strong>ternational voltage & frequency comb<strong>in</strong>ations O OStatic Transfer Switch (STS)STS on transformer primary S N/ASTS on transformer secondary N/A SFive switch STS bypass circuit S SSix switch STS bypass circuit O OTransformer Input BreakersS<strong>in</strong>gle circuit breaker (for s<strong>in</strong>gle transformer systems) S N/ATwo circuit breakers (for dual transformer systems) O SLightn<strong>in</strong>g Arrestor/Surge SuppressorHigh energy surge protection on the transformer primary O OIsolation TransformersK-13 rated S SK-20 rated O ODual impedance matched transformers O SHarmonic mitigat<strong>in</strong>g transformers O N/ATransient Voltage Surge SuppressionOne stage (L-N) @ 80,000 Amps total O OTwo stage (L-N & N-G) @ 160,000 Amps total O OThree stage (L-N, N-G & L-G) @ 240,000 Amps total O OFocus Microprocessor Controlled Monitor<strong>in</strong>gTrue RMS voltage, current, kVA, demand, alarm<strong>in</strong>g, etc. S SThree phase sag/surge transient, THD monitor O ODistribution PanelboardsTwo through eight 42-pole panelboards available S S225 amp secondary ma<strong>in</strong> breaker feed<strong>in</strong>g each panelboard S SPanelboards for “Dual Corded” loads N/A OSubfeed Distribution BreakersUp to four 225A 3-pole breakers <strong>in</strong> lieu of a panelboard O OS = Standard O = Optional N/A = Not AvailableTwo ma<strong>in</strong> breakers, two impedance-matched transformers, anda five-device STS are comb<strong>in</strong>ed to create the ultimate MissionCritical PDM.The chart above illustrates standard and optional features of theMC-3 and MC-4 systems to help you determ<strong>in</strong>e which MissionCritical configuration most closely meets your requirements.Semi-conductor fabrication relies on robotic systemsto ensure efficiency and reliability <strong>in</strong> production.Microprocessor-controlled mach<strong>in</strong>e toolsprovide absolute repeatability and require missioncritical power distribution to ensure quality products.United <strong>Power</strong>’s Series MC PDMs can be custom-eng<strong>in</strong>eeredto meet the power distributionrequirements of any manufactur<strong>in</strong>g need.


Series MC PDMsGeneral SpecificationskVA75-300 kVA, 3-phaseInputDual feed compatible3-phase, 3 wire plus ground208, 480 or 600 Vac, 60 HzOutput3-phase, 4 wire plus ground208/120 Vac, 60 HzTransformerK-13, K-20 optionalDouble shieldedCopper w<strong>in</strong>d<strong>in</strong>gsCompensation taps:2 @ 2.5% above nom<strong>in</strong>al4 @ 2.5% below nom<strong>in</strong>alGroundS<strong>in</strong>gle po<strong>in</strong>t per FIPS PUB 94Static Transfer Switch (MC-3 & MC-4)100% rated for cont<strong>in</strong>uous duty100% non-l<strong>in</strong>ear load capability1/4 cycle transfer timeWrap around ma<strong>in</strong>tenance bypassDistribution225A, 42-pole panelsMa<strong>in</strong> CB protection per panelPlug-<strong>in</strong> or bolt-on branch CBsSub-feed breakers available (>100A)Meter<strong>in</strong>g (True RMS)Input voltage and output voltagePhase A, B, C, neutral and grd currentkVA, kW, kWHFrequencyPercent load<strong>Power</strong> factorSag/surge/transient/THD (optional)Alarm<strong>in</strong>gHigh voltageLow voltageHigh currentPhase lossGround faultPhase rotationTransformer high temperatureTransformer shutdownSummary alarmAnnunciation80-character LCD displayAlarm hornAcknowledge pushbuttonIllum<strong>in</strong>ated EPO pushbutton<strong>Power</strong> flow mimic panel (MC2-4)Physical Specifications: Series MC PDMs (480 Vac Input, 60 Hz)Model No. kVA Panelboards Width (In)* Depth (In) Height (In) Weight (Lb)MC-1MC1MC1MC1MC1MC1MC1MC-2MC2MC2MC2MC2MC2MC2MC-3MC3MC3MC3MC3MC3MC3MC-4MC4MC4MC4MC4MC4MC475100125150200225300751001251502002253007510012515020022530075100125150200225300444444444444464444444444444643.543.543.543.543.543.553989898989898117109.5109.5109.5109.5109.5109.5109.5129129129129129129149Consult factory for MC PDM systems requir<strong>in</strong>g other voltage configurations.* United <strong>Power</strong> offers a wide variety of output distribution options. Width dimension is subjectto change based on different output distribution configurations.* All dimensions are for systems requir<strong>in</strong>g front access only for rout<strong>in</strong>e field service. Widthdimension may be reduced when rear clearance is available. Consult factory for applicationsassistance and custom AutoCAD draw<strong>in</strong>g generation for your custom MC PDM.UL478 (PDM) and 1008 (STS) Listed • NEMA • NEC • ANSI • IEEE • FIPS 94UNITEDPOWER34343434343434343434343434343434343434343434343434343434696969696969696969696969696969696969696969696969696969691,2501,3601,5201,6301,9002,0102,7802,3502,5702,8903,1103,6503,8705,3102,4502,5602,7202,8303,1003,2103,9503,1403,3603,6804,2004,5804,8006,700United <strong>Power</strong> Corporation2132 Tomlynn Street, Richmond, VA 23230(804) 359-6500 (800) 545-4426FAX (804) 359-6659www.unitedpowercorp.comProduct <strong>in</strong><strong>format</strong>ion is subject to change as warranted by manufactur<strong>in</strong>g or eng<strong>in</strong>eer<strong>in</strong>g processes.United <strong>Power</strong> reserves the right to make changes, additions or deletions <strong>in</strong> equipment design and/orcomponents.MC 8PG 3/98-15K