VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire
VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire
11 Supplement11 Supplement11.1 Technical dataGeneral dataMaterials, wetted partsƲ Adapter flangePPƲ Seal, adapter flangeFKM (COG VI500), EPDM (COG AP310)Ʋ Antenna PBT-GF 30Ʋ Focussing lensePPMaterials, non-wetted partsƲ Compression flangePPƲ Mounting strap316LƲ Fixing screws, mounting strap 316LƲ Fixing screws, adapter flange 304Ʋ Housingplastic PBT (Polyester)Ʋ type label support on cablePE hardProcess fitting, mounting thread on the housingƲ FlangeDIN from DN 80, ANSI from 3", JIS from DN 100 10KƲ Pipe thread, cylindrical (ISO 228 T1) G1½Instrument weight, depending on process0.7 … 3.4 kg (1.543 … 7.496 lbs)fittingWeight suspension cable0.1 kg/m (0.07 lbs/ft)Max. torque for mounting strap on sensor 4 NmhousingMax. torque flange screwsƲ Compression flange DN 805 Nm (3.689 lbf ft)Ʋ Adapter flange DN 1007 Nm (5.163 lbf ft)Input variableMeasured variableThe measured variable is the distance between the processfitting of the sensor and the product surface. Thereference plane is the lower side of the flange.44VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire38061-EN-121011
11 Supplement3142Fig. 44: Data of the input variable1 Reference plane2 Measured variable, max. measuring range3 Antenna length4 Useful measuring rangeMax. measuring range15 m (49.21 ft)Output variableOutput signal4 … 20 mA/HARTFulfilled HART specification 7.0Signal resolution 0.3 µAFailure signal current output (adjustable) mA-value unchanged 20.5 mA, 22 mA, < 3.6 mAMax. output current22 mAStarting current≤ 3.6 mA; ≤ 10 mA for 5 ms after switching onLoadsee load diagram under Power supplyDamping (63 % of the input variable), 0 … 999 sadjustableHART output values according to HART 7.0 1)Ʋ PV (Primary Value)Distance to the levelƲ SV (Secondary Value)Level as percentage valueƲ TV (Third Value)Linearised percentage valueƲ QV (Fourth Value)Scaled measured valueResolution, digital< 1 mm (0.039 in)38061-EN-121011Accuracy (according to DIN EN 60770-1)Process reference conditions according to DIN EN 61298-1Ʋ Temperature+18 … +30 °C (+64 … +86 °F)Ʋ Relative humidity 45 … 75 %Ʋ Air pressure860 … 1060 mbar/86 … 106 kPa (12.5 … 15.4 psig)1)Default values, can be assigned individuallyVEGAPULS WL 61 • 4 … 20 mA/HART - two-wire45
- Page 1 and 2: Operating InstructionsRadar sensor
- Page 3 and 4: Quick start0,5 m(19.68")100%25 m(19
- Page 5 and 6: Contents10 Dismounting10.1 Dismount
- Page 7 and 8: 2 For your safety2 For your safety2
- Page 9 and 10: 2 For your safetytection. The envir
- Page 11 and 12: 3 Product descriptionScope of deliv
- Page 13 and 14: 4 Mounting4 MountingSuitability for
- Page 15 and 16: 4 Mounting> 200 mm(7.87")Fig. 8: Ve
- Page 17 and 18: 4 MountingFig. 12: Rotation in the
- Page 19 and 20: 4 MountingFig. 16: Mounting of the
- Page 21 and 22: 4 MountingFoam generationFlow measu
- Page 23 and 24: 5 Connecting to power supply5 Conne
- Page 25 and 26: 6 Set up with VEGADIS 626 Set up wi
- Page 27 and 28: 6 Set up with VEGADIS 62Information
- Page 29 and 30: TWISTUSB7 Setup with PACTwareVia in
- Page 31 and 32: 7 Setup with PACTwareIf these value
- Page 33 and 34: 9 Diagnosis, Asset Management and s
- Page 35 and 36: 9 Diagnosis, Asset Management and s
- Page 37 and 38: 9 Diagnosis, Asset Management and s
- Page 39 and 40: 9 Diagnosis, Asset Management and s
- Page 41 and 42: 9 Diagnosis, Asset Management and s
- Page 43: 10 Dismounting10 Dismounting10.1 Di
- Page 47 and 48: 11 SupplementTracking speed of the
- Page 49 and 50: 11.2 Radio astronomy stations11 Sup
- Page 51 and 52: 11 SupplementVEGAPULS WL 61, versio
- Page 53 and 54: 11 SupplementVEGAPULS WL 61, versio
- Page 55 and 56: 11 Supplement11.4 Industrial proper
- Page 57 and 58: Notes38061-EN-121011VEGAPULS WL 61
- Page 59 and 60: Notes38061-EN-121011VEGAPULS WL 61
11 Supplement11 Supplement11.1 Technical dataGeneral dataMaterials, wetted partsƲ Adapter flangePPƲ Seal, adapter flangeFKM (COG VI500), EPDM (COG AP310)Ʋ Antenna PBT-GF 30Ʋ Focussing lensePPMaterials, non-wetted partsƲ Compression flangePPƲ Mounting strap316LƲ Fixing screws, mounting strap 316LƲ Fixing screws, adapter flange 304Ʋ Housingplastic PBT (Polyester)Ʋ type label support on cablePE hardProcess fitting, mounting thread on the housingƲ FlangeDIN from DN 80, ANSI from 3", JIS from DN 100 10KƲ Pipe thread, cylindrical (ISO 228 T1) G1½Instrument weight, depending on process0.7 … 3.4 kg (1.543 … 7.496 lbs)fittingWeight suspension cable0.1 kg/m (0.07 lbs/ft)Max. torque for mounting strap on sensor 4 NmhousingMax. torque flange screwsƲ Compression flange DN 805 Nm (3.689 lbf ft)Ʋ Adapter flange DN 1007 Nm (5.163 lbf ft)Input variableMeasured variableThe measured variable is the distance between the processfitting of the sensor and the product surface. Thereference plane is the lower side of the flange.44<strong>VEGAPULS</strong> <strong>WL</strong> <strong>61</strong> • 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong> - <strong>two</strong>-<strong>wire</strong>380<strong>61</strong>-EN-121011