7 Setup with PACTware7 Setup with PACTware7.1 Connect the PCVia interface adapter tothe signal cable2 4LOCK13TWISTOPENUSB5Fig. 25: Connecting the PC to the signal cable1 Sensor2 HART resistance 250 Ω (optional depending on processing)3 Connection cable with 2 mm pins and terminals4 Processing system/PLC/Voltage supply5 Interface adapter, for example VEGACONNECT 4Note:With power supply units with integrated HART resistance (internalresistance approx. 250 Ω), an additional external resistance is notnecessary. This applies, e.g. to the VEGA instruments VEGATRENN149A, VEGAMET 381, VEGAMET 391. Common Ex separators arealso usually equipped with a sufficient current limitation resistance. Insuch cases, the interface converter can be connected parallel to the4 … 20 mA cable (dashed line in the previous illustration).28VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire38061-EN-121011
TWISTUSB7 Setup with PACTwareVia interface adapter tothe VEGAMET signal conditioninginstrument1 23122on%1OPENLOCKVEGAMET 3814Fig. 26: Connection of the PC to the VEGAMET signal conditioning instrument1 Sensor2 Connection cable with 2 mm pins3 Signal conditioning instrument, e.g. VEGAMET 3814 Interface adapter, for example VEGACONNECT 4Prerequisites7.2 Parameter adjustment with PACTwareFor parameter adjustment of the sensor via a Windows PC, the configurationsoftware PACTware and a suitable instrument driver (DTM)according to FDT standard are required. The up-to-date PACTwareversion as well as all available DTMs are compiled in a DTM Collection.The DTMs can also be integrated into other frame applicationsaccording to FDT standard.Note:To ensure that all instrument functions are supported, you shouldalways use the latest DTM Collection. Furthermore, not all describedfunctions are included in older firmware versions. You can downloadthe latest instrument software from our homepage. A description ofthe update procedure is also available in the Internet.Further setup steps are described in the operating instructions manual"DTM Collection/PACTware" attached to each DTM Collection andwhich can also be downloaded from the Internet. Detailed descriptionsare available in the online help of PACTware and the DTMs.38061-EN-121011VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire29
- Page 1 and 2: Operating InstructionsRadar sensor
- Page 3 and 4: Quick start0,5 m(19.68")100%25 m(19
- Page 5 and 6: Contents10 Dismounting10.1 Dismount
- Page 7 and 8: 2 For your safety2 For your safety2
- Page 9 and 10: 2 For your safetytection. The envir
- Page 11 and 12: 3 Product descriptionScope of deliv
- Page 13 and 14: 4 Mounting4 MountingSuitability for
- Page 15 and 16: 4 Mounting> 200 mm(7.87")Fig. 8: Ve
- Page 17 and 18: 4 MountingFig. 12: Rotation in the
- Page 19 and 20: 4 MountingFig. 16: Mounting of the
- Page 21 and 22: 4 MountingFoam generationFlow measu
- Page 23 and 24: 5 Connecting to power supply5 Conne
- Page 25 and 26: 6 Set up with VEGADIS 626 Set up wi
- Page 27: 6 Set up with VEGADIS 62Information
- Page 31 and 32: 7 Setup with PACTwareIf these value
- Page 33 and 34: 9 Diagnosis, Asset Management and s
- Page 35 and 36: 9 Diagnosis, Asset Management and s
- Page 37 and 38: 9 Diagnosis, Asset Management and s
- Page 39 and 40: 9 Diagnosis, Asset Management and s
- Page 41 and 42: 9 Diagnosis, Asset Management and s
- Page 43 and 44: 10 Dismounting10 Dismounting10.1 Di
- Page 45 and 46: 11 Supplement3142Fig. 44: Data of t
- Page 47 and 48: 11 SupplementTracking speed of the
- Page 49 and 50: 11.2 Radio astronomy stations11 Sup
- Page 51 and 52: 11 SupplementVEGAPULS WL 61, versio
- Page 53 and 54: 11 SupplementVEGAPULS WL 61, versio
- Page 55 and 56: 11 Supplement11.4 Industrial proper
- Page 57 and 58: Notes38061-EN-121011VEGAPULS WL 61
- Page 59 and 60: Notes38061-EN-121011VEGAPULS WL 61
7 Setup with PACTware7 Setup with PACTware7.1 Connect the PCVia interface adapter tothe signal cable2 4LOCK13TWISTOPENUSB5Fig. 25: Connecting the PC to the signal cable1 Sensor2 <strong>HART</strong> resistance 250 Ω (optional depending on processing)3 Connection cable with 2 mm pins and terminals4 Processing system/PLC/Voltage supply5 Interface adapter, for example VEGACONNECT 4Note:With power supply units with integrated <strong>HART</strong> resistance (internalresistance approx. 250 Ω), an additional external resistance is notnecessary. This applies, e.g. to the VEGA instruments VEGATRENN149A, VEGAMET 381, VEGAMET 391. Common Ex separators arealso usually equipped with a sufficient current limitation resistance. Insuch cases, the interface converter can be connected parallel to the4 … <strong>20</strong> <strong>mA</strong> cable (dashed line in the previous illustration).28<strong>VEGAPULS</strong> <strong>WL</strong> <strong>61</strong> • 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong> - <strong>two</strong>-<strong>wire</strong>380<strong>61</strong>-EN-121011