4 MountingFlow measurement withKhafagi Venturi flumed90°3 ... 4 x h maxh max21BFig. 22: Flow measurement with Khafagi-Venturi flume: d = Min. distance to sensor;h max.= max. filling of the flume; B = tightest constriction in the flume1 Position sensor2 Venturi flumeIn general, the following points must be observed:Installation of the sensor at the inlet side• Installation in the centre of the flume and vertical to the liquidsurfaceDistance to the Venturi flume• Min. distance of the sensor to max. storage level22<strong>VEGAPULS</strong> <strong>WL</strong> <strong>61</strong> • 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong> - <strong>two</strong>-<strong>wire</strong>380<strong>61</strong>-EN-121011