VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire
VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire VEGAPULS WL 61 - 4 ⦠20 mA/HART - two-wire
4 Mounting1Fig. 10: Horizontal mounting with the optional mounting strap with integratedreflector1 Reference planeInformation:With this combination (by default), the offset is already taken into account.The lower side of the mountng seal is the reference plane.FlangeFor mounting the instrument on a socket or a manhole cover, an unassembledcombination compression flange is optionally available forDN 80 (ASME 3" or JIS 80), also as a retrofitting part. As an alternative,the instrument can be already supplied with a tight, fix-mountedadapter flange from DN 100 (ASME 4" or JIS 100).You can find drawings of these mounting options in chapter "Dimensions".Fig. 11: Mounting by means of an adapter flange, for example, on a manhole lid.164.3 Mounting preparations, mounting strapThe optional mounting strap is supplied unassembled. It must bescrewed to the sensor before setup with the attached screws. Max.torque, see chapter "Technical data". Required tools: Allen wrenchsize 4.There are two different ways of screwing the strap to the sensor.Depending on the selected method, the sensor can be rotated inthe strap infinitely variable through 180° or in three steps 0°, 90° and180°.VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire38061-EN-121011
4 MountingFig. 12: Rotation in the centre with ceiling mountingFig. 13: Adjustment of the angle of inclination in case of wall mountingTight installation of theplastic horn antennaPolarisation plane4.4 Instructions for installationFor tight installation of the version with plastic horn antenna with compressionor adapter flange, the following conditions must be fulfilled:1. Use suitable flat seal, e.g. of EPDM with Shore hardness 25 or 502. Make sure the number of flange screws corresponds to the numberof flange holes3. Tighten all screws with the torque stated in the technical dataThe emitted radar impulses of the radar sensor are electromagneticwaves. The polarisation plane is the direction of the electrical wavecomponent. By turning the instrument in the connection flange ormounting strap, the polarisation can be used to reduce the effects offalse echoes.The position of the polarisation level is marked by marking bars on theinstrument.38061-EN-121011VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire17
- Page 1 and 2: Operating InstructionsRadar sensor
- Page 3 and 4: Quick start0,5 m(19.68")100%25 m(19
- Page 5 and 6: Contents10 Dismounting10.1 Dismount
- Page 7 and 8: 2 For your safety2 For your safety2
- Page 9 and 10: 2 For your safetytection. The envir
- Page 11 and 12: 3 Product descriptionScope of deliv
- Page 13 and 14: 4 Mounting4 MountingSuitability for
- Page 15: 4 Mounting> 200 mm(7.87")Fig. 8: Ve
- Page 19 and 20: 4 MountingFig. 16: Mounting of the
- Page 21 and 22: 4 MountingFoam generationFlow measu
- Page 23 and 24: 5 Connecting to power supply5 Conne
- Page 25 and 26: 6 Set up with VEGADIS 626 Set up wi
- Page 27 and 28: 6 Set up with VEGADIS 62Information
- Page 29 and 30: TWISTUSB7 Setup with PACTwareVia in
- Page 31 and 32: 7 Setup with PACTwareIf these value
- Page 33 and 34: 9 Diagnosis, Asset Management and s
- Page 35 and 36: 9 Diagnosis, Asset Management and s
- Page 37 and 38: 9 Diagnosis, Asset Management and s
- Page 39 and 40: 9 Diagnosis, Asset Management and s
- Page 41 and 42: 9 Diagnosis, Asset Management and s
- Page 43 and 44: 10 Dismounting10 Dismounting10.1 Di
- Page 45 and 46: 11 Supplement3142Fig. 44: Data of t
- Page 47 and 48: 11 SupplementTracking speed of the
- Page 49 and 50: 11.2 Radio astronomy stations11 Sup
- Page 51 and 52: 11 SupplementVEGAPULS WL 61, versio
- Page 53 and 54: 11 SupplementVEGAPULS WL 61, versio
- Page 55 and 56: 11 Supplement11.4 Industrial proper
- Page 57 and 58: Notes38061-EN-121011VEGAPULS WL 61
- Page 59 and 60: Notes38061-EN-121011VEGAPULS WL 61
4 Mounting1Fig. 10: Horizontal mounting with the optional mounting strap with integratedreflector1 Reference planeInformation:With this combination (by default), the offset is already taken into account.The lower side of the mountng seal is the reference plane.FlangeFor mounting the instrument on a socket or a manhole cover, an unassembledcombination compression flange is optionally available forDN 80 (ASME 3" or JIS 80), also as a retrofitting part. As an alternative,the instrument can be already supplied with a tight, fix-mountedadapter flange from DN 100 (ASME 4" or JIS 100).You can find drawings of these mounting options in chapter "Dimensions".Fig. 11: Mounting by means of an adapter flange, for example, on a manhole lid.164.3 Mounting preparations, mounting strapThe optional mounting strap is supplied unassembled. It must bescrewed to the sensor before setup with the attached screws. Max.torque, see chapter "Technical data". Required tools: Allen wrenchsize 4.There are <strong>two</strong> different ways of screwing the strap to the sensor.Depending on the selected method, the sensor can be rotated inthe strap infinitely variable through 180° or in three steps 0°, 90° and180°.<strong>VEGAPULS</strong> <strong>WL</strong> <strong>61</strong> • 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong> - <strong>two</strong>-<strong>wire</strong>380<strong>61</strong>-EN-121011