3 Product descriptionStorage and transporttemperatureInterface adapterExternal indicating andadjustment unit withHART protocol• Storage and transport temperature see chapter "Supplement -Technical data - Ambient conditions"• Relative humidity 20 … 85 %3.4 Accessories and replacement partsThe interface adapter VEGACONNECT enables the connection ofcommunication-capable instruments to the USB interface of a PC. Forparameter adjustment of these instruments, an adjustment softwaresuch as PACTware with VEGA-DTM is required.You can find further information in the operating instructions "Interfaceadapter VEGACONNECT" (Document-ID 32628).VEGADIS 62 is suitable for measured value indication and adjustmentof sensors with HART protocol. It is looped into the 4 … 20 mA/HARTsignal cable.You can find further information in the operating instructions "VE-GADIS 62" (Document-ID 36469).12VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire38061-EN-121011
4 Mounting4 MountingSuitability for the processconditionsStraining clamp4.1 General instructionsMake sure that all parts of the instrument exposed to the process, inparticular the active measuring component, process seal and processfitting, are suitable for the existing process conditions. These includeabove all the process pressure, process temperature as well as thechemical properties of the medium.You can find the specifications in chapter "Technical data" and on thetype label.4.2 Mounting versionsMost simply mount the instrument via the straining clamp. For thispurpose, the connection cable is provided with a strain relief wire ofKevlar.In order to avoid faulty measured values, make sure that the sensordoes not oscillate.> 200 mm(7.87")Fig. 5: Mounting via a straining clampMounting bracketFor a rigid mounting, a mounting bracket with opening for threadG1½, e.g. from the VEGA product range, is recommended. Themounting of the sensor in the bracket is carried out via a G1½ counternut of plastic. Take note of chapter "Mounting instructions" for thedistance to the wall.38061-EN-121011VEGAPULS WL 61 • 4 … 20 mA/HART - two-wire13
- Page 1 and 2: Operating InstructionsRadar sensor
- Page 3 and 4: Quick start0,5 m(19.68")100%25 m(19
- Page 5 and 6: Contents10 Dismounting10.1 Dismount
- Page 7 and 8: 2 For your safety2 For your safety2
- Page 9 and 10: 2 For your safetytection. The envir
- Page 11: 3 Product descriptionScope of deliv
- Page 15 and 16: 4 Mounting> 200 mm(7.87")Fig. 8: Ve
- Page 17 and 18: 4 MountingFig. 12: Rotation in the
- Page 19 and 20: 4 MountingFig. 16: Mounting of the
- Page 21 and 22: 4 MountingFoam generationFlow measu
- Page 23 and 24: 5 Connecting to power supply5 Conne
- Page 25 and 26: 6 Set up with VEGADIS 626 Set up wi
- Page 27 and 28: 6 Set up with VEGADIS 62Information
- Page 29 and 30: TWISTUSB7 Setup with PACTwareVia in
- Page 31 and 32: 7 Setup with PACTwareIf these value
- Page 33 and 34: 9 Diagnosis, Asset Management and s
- Page 35 and 36: 9 Diagnosis, Asset Management and s
- Page 37 and 38: 9 Diagnosis, Asset Management and s
- Page 39 and 40: 9 Diagnosis, Asset Management and s
- Page 41 and 42: 9 Diagnosis, Asset Management and s
- Page 43 and 44: 10 Dismounting10 Dismounting10.1 Di
- Page 45 and 46: 11 Supplement3142Fig. 44: Data of t
- Page 47 and 48: 11 SupplementTracking speed of the
- Page 49 and 50: 11.2 Radio astronomy stations11 Sup
- Page 51 and 52: 11 SupplementVEGAPULS WL 61, versio
- Page 53 and 54: 11 SupplementVEGAPULS WL 61, versio
- Page 55 and 56: 11 Supplement11.4 Industrial proper
- Page 57 and 58: Notes38061-EN-121011VEGAPULS WL 61
- Page 59 and 60: Notes38061-EN-121011VEGAPULS WL 61
3 Product descriptionStorage and transporttemperatureInterface adapterExternal indicating andadjustment unit with<strong>HART</strong> protocol• Storage and transport temperature see chapter "Supplement -Technical data - Ambient conditions"• Relative humidity <strong>20</strong> … 85 %3.4 Accessories and replacement partsThe interface adapter VEGACONNECT enables the connection ofcommunication-capable instruments to the USB interface of a PC. Forparameter adjustment of these instruments, an adjustment softwaresuch as PACTware with VEGA-DTM is required.You can find further information in the operating instructions "Interfaceadapter VEGACONNECT" (Document-ID 32628).VEGADIS 62 is suitable for measured value indication and adjustmentof sensors with <strong>HART</strong> protocol. It is looped into the 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong>signal cable.You can find further information in the operating instructions "VE-GADIS 62" (Document-ID 36469).12<strong>VEGAPULS</strong> <strong>WL</strong> <strong>61</strong> • 4 … <strong>20</strong> <strong>mA</strong>/<strong>HART</strong> - <strong>two</strong>-<strong>wire</strong>380<strong>61</strong>-EN-121011