Operation Manual - Home Mega Global Solution

Operation Manual - Home Mega Global Solution Operation Manual - Home Mega Global Solution

megaglobalsolution.com
from megaglobalsolution.com More from this publisher
12.07.2015 Views

5. ELECTRICAL CONNECTIONSConnections to the Module are via plug and sockets.5.1 CONNECTION DETAILSThe following describes the connections and recommended cable sizes to the 6 plugs and socketson the rear of the Module. See rear panel layout FIG 5.PLUG “A” 18 WAYPIN DESCRIPTION CABLENOTESNoSIZE*1 Oil Pressure sender +ve 0.5mm or digital pressure switch connection.2 Oil Pressure sender -ve 0.5mm3 Oil Pressure sender -ve 0.5mm for use with insulated return type sendersfeed4 Fuel level sender +ve 0.5mm or digital fuel level switch connection5 Fuel level sender -ve 0.5mm6 Fuel level sender -ve feed 0.5mm for use with insulated return type senders7 Engine Coolant Temp. +ve 0.5mm or digital temperature switch input8 Engine Coolant Temp. -ve 0.5mm9 Engine Coolant Temp. -ve 0.5mm for use with insulated return type sendersfeed10 Engine Oil Temp. +ve 0.5mm or digital temperature switch input11 Engine Oil Temp. -ve 0.5mm12 Engine Oil Temp. -ve feed 0.5mm for use with insulated return type senders13 DO NOT USE Ensure no connection is made to this pin14 Generator CT on L1 2.5mm Do not fit resistors to CT’s15 Generator CT on L2 2.5mm if single phase then not used16 Generator CT on L3 2.5mm if single phase then not used17 CT common if Neutral CT 2.5mm only use if neutral CT fittedfitted18 Neutral CT if fitted 2.5mm If no neutral CT fitted use as CT commonPLUG “B” 15 WAYPIN DESCRIPTION CABLENOTESNoSIZE*19 Output 8 Normally closed 0.5mm Normally spare20 Output 8 Common0.5mm “ “connection21 Output 8 Normally open 0.5mm “ “22 DO NOT USE Ensure no connection is made to this pin23 Output 7 Normally closed 0.5mm Normally spare24 Output 7 Common0.5mm “ “connection25 Output 7 Normally open 0.5mm “ “26 DO NOT USE Ensure no connection is made to this pin.27 Output 6 Normally closed 0.5mm Normally Generator contactor control unlessusing breaker control. Then used forgenerator ACB close connection28 Output 6 Common0.5mm “ “ “connection29 Output 6 Normally open 0.5mm “ “ “30 DO NOT USE Ensure not connection is made to this pin20607 OPERATING MANUAL ISSUE 1 11/27/00 MR

PIN DESCRIPTION CABLENOTESNoSIZE*31 Output 5 Normally closed 0.5mm Normally spare unless using breaker control.Then used for generator ACB shunt trip orUV coil feed.32 Output 5 Common0.5mm “ “ “connection33 Output 5 Normally open 0.5mm “ “ “PLUG “C” 12 WAYPIN DESCRIPTION CABLENOTESNoSIZE*34 35 Output 1 Volt Free 0.5mm Normally configured for Common alarmoutput. Refer to the source of your moduleconfiguration for full details.3637Output 2 Volt Free 0.5mm Normally configured for Engine Pre-heateroutput. Refer config source.3839Output 3 Volt Free 0.5mm Normally configured for engine intake airflapoutput. Refer config source.4041Output 4 Volt Free 0.5mm Normally configured for fuel transfer controloutput. Refer config source.4243Output 9 Volt Free 0.5mm Normally configured for common shutdownalarm output. Refer config source.4445Output 10 Volt Free 0.5mm Normally configured for common warningalarm output. Refer config source.PLUG “D” 13 WAYPIN DESCRIPTION CABLENOTESNoSIZE*46 RS485 line A 2 core- For use with future developments47 RS485 line B -screen- “ “ “48 RS485 Screen -cable. “ “ “49 DO NOT CONNECT Ensure no connection is made to this pin50 Plant Battery -ve input 2.5mm51 Plant Battery +ve input 2.5mm Feed via 2A rated fuse.52 Charge alternator input 0.5mm Connect to WL terminal on chargealternator53 -ve Modem Power output 0.5mm Output to modem54 +ve Modem Power output 0.5mm Output to modem55 DO NOT USE Ensure no connection is made to this pin56 Fuel solenoid output 2.5mm Fed internally from EM Stop input57 Starter solenoid output 2.5mm Fed internally from EM stop input58 Emergency stop +ve input 2.5mm Feed via 15A rated fuse. Internally connectto fuel and crank outputs.607 OPERATING MANUAL ISSUE 1 11/27/00 MR 21

5. ELECTRICAL CONNECTIONSConnections to the Module are via plug and sockets.5.1 CONNECTION DETAILSThe following describes the connections and recommended cable sizes to the 6 plugs and socketson the rear of the Module. See rear panel layout FIG 5.PLUG “A” 18 WAYPIN DESCRIPTION CABLENOTESNoSIZE*1 Oil Pressure sender +ve 0.5mm or digital pressure switch connection.2 Oil Pressure sender -ve 0.5mm3 Oil Pressure sender -ve 0.5mm for use with insulated return type sendersfeed4 Fuel level sender +ve 0.5mm or digital fuel level switch connection5 Fuel level sender -ve 0.5mm6 Fuel level sender -ve feed 0.5mm for use with insulated return type senders7 Engine Coolant Temp. +ve 0.5mm or digital temperature switch input8 Engine Coolant Temp. -ve 0.5mm9 Engine Coolant Temp. -ve 0.5mm for use with insulated return type sendersfeed10 Engine Oil Temp. +ve 0.5mm or digital temperature switch input11 Engine Oil Temp. -ve 0.5mm12 Engine Oil Temp. -ve feed 0.5mm for use with insulated return type senders13 DO NOT USE Ensure no connection is made to this pin14 Generator CT on L1 2.5mm Do not fit resistors to CT’s15 Generator CT on L2 2.5mm if single phase then not used16 Generator CT on L3 2.5mm if single phase then not used17 CT common if Neutral CT 2.5mm only use if neutral CT fittedfitted18 Neutral CT if fitted 2.5mm If no neutral CT fitted use as CT commonPLUG “B” 15 WAYPIN DESCRIPTION CABLENOTESNoSIZE*19 Output 8 Normally closed 0.5mm Normally spare20 Output 8 Common0.5mm “ “connection21 Output 8 Normally open 0.5mm “ “22 DO NOT USE Ensure no connection is made to this pin23 Output 7 Normally closed 0.5mm Normally spare24 Output 7 Common0.5mm “ “connection25 Output 7 Normally open 0.5mm “ “26 DO NOT USE Ensure no connection is made to this pin.27 Output 6 Normally closed 0.5mm Normally Generator contactor control unlessusing breaker control. Then used forgenerator ACB close connection28 Output 6 Common0.5mm “ “ “connection29 Output 6 Normally open 0.5mm “ “ “30 DO NOT USE Ensure not connection is made to this pin20607 OPERATING MANUAL ISSUE 1 11/27/00 MR

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!