Structure of the classification matrix for Thick and Thin Places (NSLT)CharacteristicsDescriptionFault classificationFault lengths A: shorter than 1 cmB+TB:1 to 2 cmC+TC:2 to 4 cmD+TD:4 to 8 cmE: longer than 8 cmF+H:8 to 32 cmG+I:longer than 32 cmFault sizes 0: +45 to +100%1: +100 to +150%2: +150 to +250%3: +250 to +400%4: over +400%E: over +100%F+G: +45 to 100%DP2/FP21/FP22/GP21/GP22: +30 to +45%CP1/DP1: +45 to +75%TB1/TC1/TD1/H1/I1: -30 to -45%TB2/TC2/TD2/H2/I2: -45 to -75%Fault channels of the clearersN channel for very short thick placesS channel for short thick placesL channel for long thick placesT channel for long thin placesC channel for count deviationsSensitivityReference lengthN channel: +100% to +500% 0.1 to 1 cmS channel: +50% to +300% 1 to 10 cmL channel: +10% to +200% 1 to 200 cmT channel: -10% to -80% 10 to 200 cmC channel: ±5% to ±80% 12.8 mTable 4-17 Classing matrix of the USTER ® CLASSIMAT 5 for Thin and Thick Places (NSLT)USTER ® STATISTICS 26 (36)