Packet over SONET modules 3Path Trace (J1 byte) fieldThe Path Trace (J1 byte) field in the SONET payload envelope (SPE) transmits a 64-byte,fixed-length string that the receiving Path Terminating Equipment uses to verify the connection tothe sending device. You can configure the string that a POS interface transmits in the Path Tracefield, <strong>and</strong> you can display Path Trace strings received <strong>and</strong> configured on the POS interface.Cable specificationsTable 5 lists the cable specifications for POS modules.TABLE 5TransceiverPOS interface specificationsPowerbudgetLaunchwindowTransmit power Receive power MaximumdistanceOC-3c POS interfacesSingle-mode short-reach 13 dB 1270 to1380 nmSingle-mode intermediate-reach 29 dB 1280 to1335 nmMultimode 11.5 dB 1270 to1380 nmOC-12c POS interfacesSingle-mode long-reach 25 dBm 1280 to1335 nmSingle-mode intermediate-reach 13 dBm 1274 to1356 nmMultimode short-reach 6 dBm 1270 to1380 nmOC-48c POS interfacesSingle-mode short-reach 8 dB 1260 to1580 nmSingle-mode intermediate-reach 13 dB 1260 to1360 nm-28 to -8 dBm -31 to -8 dBm 9.75 miles(15 Km)-5 to 0 dBm -34 to -8 dBm 26 miles(40 Km)-18 to -14 dBm -30 to -14 dBm 1.3 miles(2 Km)-3 to 2 dBm -28 to -8 dBm 65 miles(100 Km)-15 to -8 dBm -28 to -7 dBm 9.32 miles(40 Km) 1-20 to -14 dBm -26 to -14 dBm 1640 ft.(500 m)-10 to -3 dBm -18 to -3 dBm 9.75 miles(15 Km)-5 to 0 dBm -18 to 0 dBm 26 miles(40 Km)1. If the transceiver part number for the OC-12c POS module is HFCT-5208B (before May 2000), the maximumdistance is 15 Km, not 40 Km.NOTEIt is recommended that you do not use Network Processor Architecture (NPA) POS modules <strong>and</strong>non-NPA POS modules in the same circuit. For example, if you have an NPA module on one end of aPOS link, do not use a non-NPA module on the other end of the link.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong> 6353-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!