Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2Power supplies, fans, <strong>and</strong> temperatureJun 4 14:05:06:I:Security: telnet login by debra from src IP 10.55.1.103 to PRIVILEGED EXEC modeJun 4 12:29:14:W: Latched low RX Power warning, port 4/1Jun 4 12:29:14:A: Latched low RX Power alarm, port 4/1Jun 4 12:24:15:I:System: Interface ethernet 4/1, state upJun 4 12:24:14:W: Latched low RX Power warning, port 4/1Jun 4 12:24:14:A: Latched low RX Power alarm, port 4/1Jun 4 12:24:05:I:System: Interface ethernet 4/1, state down - link downJun 4 12:24:02:I:System: Interface ethernet 4/1, state upJun 4 12:23:54:I:System: Interface ethernet 4/1, state down - link downshow fan-thresholdSyntax: show fan-thresholdThis comm<strong>and</strong> displays the current settings of temperature thresholds <strong>and</strong> fan speeds, as shownin the following example.<strong>Brocade</strong># show fan-threshold=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP) ===Fan Speed Low: -1 - 60Fan Speed Med: 57 - 70Fan Speed Med-Hi: 67 - 80Fan Speed Hi: 77 - 85state = 0 (FAN_STATE_LOW)max_ts_shut_off_count = 3shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_SNM) ===Fan Speed Low: -1 - 30Fan Speed Med: 27 - 40Fan Speed Med-Hi: 37 - 50Fan Speed Hi: 47 - 75state = 1 (FAN_STATE_MED)max_ts_shut_off_count = 3shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_LP) ===Fan Speed Low: -1 - 50Fan Speed Med: 46 - 55Fan Speed Med-Hi: 51 - 60Fan Speed Hi: 56 - 95state = 0 (FAN_STATE_LOW)max_ts_shut_off_count = 3shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_LP_XPP) ===Fan Speed Low: -1 - 50Fan Speed Med: 45 - 65Fan Speed Med-Hi: 60 - 75Fan Speed Hi: 70 - 113state = 1 (FAN_STATE_MED)max_ts_shut_off_count = 3shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_STANDBY_MP) ===Fan Speed Low: -1 - 60Fan Speed Med: 57 - 70Fan Speed Med-Hi: 67 - 80Fan Speed Hi: 77 - 85state = 0 (FAN_STATE_LOW)max_ts_shut_off_count = 3shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0=== Thermal Sensor Control Block (THERMAL_SENSOR_TEST_RULE_MP_CPU) ===Fan Speed Low: -1 - 6048 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong>53-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!