12.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Interface module diagnostics 2(387059 bytes) from code flashIronWare : Version 3.5.0T177 Copyright (c) 1996-2009 <strong>Brocade</strong> Communications, Inc.Compiled on Jul 19 2009 at 07:50:18 labeled as xmlp03500b279(3163145 bytes) from PrimaryFPGA versions:Valid PBIF Version = 2.13, Build Time = 2/14/2009 11:55:00Valid XPP Version = 3.05, Build Time = 5/14/2009 11:12:00Valid XGMAC Version = 0.11, Build Time = 10/11/2009 12:45:00Clearing traffic management statisticsTo clear traffic management statistics, enter the clear tm-voq-stat src_port dst_port comm<strong>and</strong>.The following comm<strong>and</strong>s can be useful for displaying <strong>and</strong> clearing information about interfacemodules:• clear tm-voq-stat src_port dst_port [priority]• show tm-voq-stat src_port multicast• clear tm-voq-stat src_port multicast• show tm-voq-stat src_port cpu-queue• clear tm-voq-stat src_port cpu-queueFor information about these comm<strong>and</strong>s, refer to the <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> FamilyConfiguration <strong>Guide</strong>.Interface module debug comm<strong>and</strong>sThere are no debug comm<strong>and</strong>s specific to interface modules.Common diagnostic scenariosCommon diagnostic situations involving interface modules can include the following situations:• The module is not receiving power.• A link has not been successfully established.• A port is not transmitting or receiving packets.• Packets fail to enter an ingress queue on the traffic manager. This can happen because thequeue has reached its maximum length, or Weighted R<strong>and</strong>om Early Detection (WRED) isenabled to prevent an output queue from ever filling to capacity.Interface modules continue to send traffic when a switchover occurs between managementmodules. After a switchover event, interface modules send updates to the new active managementmodule, which verifies that the interface modules are synchronized.If the new active management module becomes out of sync with an interface module, informationon the interface module may be overwritten, which can cause an interruption of traffic forwarding.This must only occur if there is a Layer 3 topology change elsewhere in the network during themanagement module switchover. <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong> series routers support<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong> 3753-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!