12.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Interface module diagnostics 2NOTE<strong>Brocade</strong> recommends that you run diagnostics on the module running with factory defaultconfiguration, so that the module does not work any protocol process while the diagnostics arerunning. If you need to configure some comm<strong>and</strong>s such as snmp-server max-ifindex-per-module to recognize the modules, the minimum configuration to recognize would be approved.To run diagnostics on an interface module, perform the following steps.1. Boot the module into interactive mode by entering the following comm<strong>and</strong>s.<strong>Brocade</strong># lp boot sys in 1<strong>Brocade</strong># Reset slot 1Slot 1: booted to Interactive Mode.2. With the module in interactive mode, remote console to the module by entering the followingcomm<strong>and</strong>.<strong>Brocade</strong># rcon 1Remote connection to LP slot 1 establishedPress CTRL-X or type 'exit' to disconnect itLP-1 Monitor>3. Boot the module in the OS mode.LP-1 Monitor>boot os flash primaryLP-1 OS>4. Run the diagnostic using the diag burn comm<strong>and</strong>. You must see output similar to the followingexample.LP-1 OS>diag burnPRAM 0 -- TM DDRII support disabledXPP PLL Status Register at 0 micro-sec = 0x0000ff0fXPP PLL Status Register at 2 micro-sec = 0x0000ff0fXPP PLL Status Register at 4 micro-sec = 0x0000ff0fXPP PLL Status Register at 6 micro-sec = 0x0000ff0fXPP PLL Status Register at 8 micro-sec = 0x0000ff0fXPP PLL Status Register at 10 micro-sec = 0x0000ff0fXPP PLL Status Register at 12 micro-sec = 0x0000ff0fXPP PLL Status Register at 14 micro-sec = 0x0000ff0fXPP PLL Status Register at 16 micro-sec = 0x0000ff0fXPP PLL Status Register at 18 micro-sec = 0x0000ff0fXPP PLL Status Register at 20 micro-sec = 0x0000ff0fXPP PLL Status Register at 22 micro-sec = 0x0000ff0fXPP PLL Status Register at 24 micro-sec = 0x0000ff0fXPP PLL Status Register at 26 micro-sec = 0x0000ff0fXPP PLL Status Register at 28 micro-sec = 0x0000ff0fXPP Reset Sequence Done - PLL Status Register = 0x0000ff0fXPP Reset Sequence Done - PLL Status Register = 0x0000ff0fXPP Reset Sequence Done - PLL Status Register = 0x00c0ffffXPP: P1 board or higher detectedPASSEDDev 0 PRAM passedSTATSRAM 0 -- PASSEDDev 0 STATSRAM passedTXVLAN Table 0 -- PASSEDDev 0 TXVLANRAM passedCAM2PRAM 0 -- PASSEDDev 0 CAMTOPRAMRAM passedAGERAM 0 -- Pass 1Pass 2<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong> 3153-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!