Management module diagnostics 2Common diagnostic scenariosManagement module switchover eventsIn a redundant management module configuration, whenever the st<strong>and</strong>by management moduleassumes the role of active module a switchover event has occurred. This happens when the activemodule becomes unavailable (for example, power is lost or a component fails), you perform amanual switchover, or you remove or replace the active management module. When a switchoveroccurs between the active <strong>and</strong> st<strong>and</strong>by modules, management sessions, syslog, <strong>and</strong> SNMP trapsmay be affected.When an active module becomes unavailableThe following events will cause an active module to become unavailable <strong>and</strong> trigger a switchover:• An active module experiences a problem significant enough to cause a reset of the module. Ifthis is a software problem, capture the output from the show tech comm<strong>and</strong>. If the outputcontains a crash dump, contact <strong>Brocade</strong> Technical Support.• The active module loses power. This may happen if a power supply fails, or because of ageneral disruption in power.Before a switchover occurs, the active module resets itself <strong>and</strong> sends an interrupt signal to thest<strong>and</strong>by module. The st<strong>and</strong>by module then becomes the active module, allowing the modules tocontinue forwarding traffic.The new active module also begins to manage the system. When the original active module againbecomes available or is replaced, the new active module resumes in the role of st<strong>and</strong>by.Management module error messagesThe following messages are displayed in the event of a switchover event, if there is a problem withthe st<strong>and</strong>by management module in a redundant configuration.Warning: Active MP running image is not in its flash or PCMCIA card, imagesynchronization is not possible:Warning: St<strong>and</strong>by Module is not allowed - put st<strong>and</strong>by MP in reset.Switchover syslog <strong>and</strong> SNMP trapsWhen a switchover occurs, the system sends a syslog message to the local syslog buffer <strong>and</strong> to thesyslog server, if one is configured. The system also sends an SNMP trap to the receiver, if one isconfigured.If the system is reset as the result of a switchover to the st<strong>and</strong>by management module, the systemsends a warm start message <strong>and</strong> trap.Monitoring management module redundancyYou can monitor the following aspects of management module redundancy:• The status of the management modules (if a module is the active or st<strong>and</strong>by module).• The switchover history for the management modules.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong> 2953-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!