2Management module diagnostics• You can allocate memory for more VLANs or virtual routing interfaces. By default, you canconfigure up to 512 VLANs <strong>and</strong> virtual routing interfaces on the router. Although this is thedefault maximum, the <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong> series devices can support upto 4094 VLANs <strong>and</strong> 4095 virtual routing interfaces. (VLAN IDs 0 <strong>and</strong> 4095 are reserved.) Ifmany of your VLANs will have an identical configuration, you might want to configure VLANgroups. To learn more about VLAN groups <strong>and</strong> how to configure them, refer to the <strong>Brocade</strong> <strong>MLX</strong><strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> Family Configuration <strong>Guide</strong>.Management module diagnosticsThe management modules control <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong> series hardwarecomponents, run networking protocols, <strong>and</strong> provide the Real Time Operating System (RTOS).Each chassis requires one management module, <strong>and</strong> can accept a second module for redundancythat works in conjunction with the active management module. If the active management modulebecomes unavailable, the redundant management module automatically takes over the systemoperation, minimizing system downtime.Running management module diagnosticsYou can run diagnostics on the management modules to check if the devices needed for properoperation are accessible <strong>and</strong> in working order. The diagnostics for the Line Processor (LP) modulesbegin after the completion of diagnostics for the management processor (MP) modules, if the LPmodules are present in the chassis.MP module is considered to have passed the diagnostics if the result of all the checks is "Passed".If an MP or an LP does not pass the diag burn-in comm<strong>and</strong>, contact <strong>Brocade</strong> Technical Support forfurther assistance.NOTERemove the st<strong>and</strong>by management module from the chassis before running the diagnostics. If thest<strong>and</strong>by management module is present, running the diagnostics on the interface module fails.To run diagnostics on management modules, perform the following steps.1. Reload the system <strong>and</strong> immediately press the B key repeatedly until the system boots intomonitor mode.2. Type boot os flash primary to enter the OS.The prompt will change from MP Monitor> to MP OS>.3. From the MP OS> prompt, enter diag burn-in, as shown in the following example.MP-1 OS>diag burn-inPCI access- Passed88E1145 PHY- PassedStorage Card- PassedM41T11 RTC- PassedFE (slot 0; FE 0; 0x11fe6000) access passed;FE (slot 0; FE 1; 0x11fe6000) access passed;FE (slot 0; FE 2; 0x11fe6000) access passed;FE (slot 1; FE 0; 0x11fe6000) access passed;FE (slot 1; FE 1; 0x11fe6000) access passed;24 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong>53-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!