12.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

Brocade MLX Series and Brocade NetIron XMR Diagnostic Guide ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MPLS API 6Nov 21 02:42:51 VLL_Peer_FSM: VC-ID: 1, Peer: 11.0.0.3[Operational] -> [Waiting for VC Withdraw] (Event: [Peer delete])Nov 21 02:42:51 VLL EVENTS: Bitmap event is DOWN, min-index 0, max-index 0Nov 21 02:42:51 VLL EVENTS: Final Index min_index 0, max-index 0Nov 21 02:42:51 VLL_MCT_FSM: VC-ID: 1[Active] -> [None] (Event: [None])Nov 21 02:42:51 VLL EVENTS: Sending VC withdrawal for VLL 1, vll-index 0, pw-index0x00000001Nov 21 02:42:51 VLL EVENTS: Bitmap Event vll-index 0, min-index 0, max-index 0Nov 21 02:42:51 VLL EVENTS: Bitmap event is DOWN, min-index 0, max-index 0Nov 21 02:42:51 VLL EVENTS: Final Index min_index 0, max-index 0Nov 21 02:42:51 VLL IPC: Sending IPC to LP as VLL 1 changed to non-operationalstateNov 21 02:42:51 VLL DY-SYNC: Trunk Outbound - vll_name = mct-vll-1, vll_id = 1,vll_port = 96, vlan_id = 401.. (output edited for brevity).Nov 21 02:42:51 VLL EVENTS: VLL VC ID 5 for Peer 11.0.0.3: current tnnl =2160, new tnnl = 2157Nov 21 02:42:51 VLL EVENTS: VLL VC ID 4 for Peer 11.0.0.3: current tnnl =2160, new tnnl = 2157Nov 21 02:42:51 VLL EVENTS: VLL VC ID 20 for Peer 11.0.0.3: current tnnl =2160, new tnnl = 2157Nov 21 02:42:51 VLL EVENTS: VLL VC ID 19 for Peer 11.0.0.3: current tnnl =2157, new tnnl = 2157Nov 21 02:42:51 VLL EVENTS : ** End peer 11.0.0.3<strong>Brocade</strong>(config-mpls)# vll mct-vll-1 1Nov 21 02:43:16 VLL EVENTS: VLL ID 1 has allocated vll-index 0Nov 21 02:43:16 VLL EVENTS: Configured VLL 1 in Tagged-mode(default-mode)<strong>Brocade</strong>(config-mpls-vll-mct-vll-1)# vll-peer 11.0.0.1 11.0.0.2<strong>Brocade</strong>(config-mpls-vll-mct-vll-1)# vlan 401<strong>Brocade</strong>(config-mpls-vll-mct-vll-1-vlan-401)# tagged e 3/1Nov 21 02:43:27 VLL IPC: Sending IPC to LP for VLL 1 to program the drop camNov 21 02:43:27 VLL DY-SYNC: Trunk Outbound - vll_name = mct-vll-1, vll_id = 1,vll_port = 96, vlan_id = 401Nov 21 02:43:27 VLL DY-SYNC: Peer 0.0.0.0, remote_vc = 0, tunnel_label = 0, modeTAGGED-MODE, action UPDATE, PW_role Active, MCT_role None, MCT_ID = 0,MCT_Client_ID = 0.. (output edited for brevity).Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 1 Received sync message (Type: [MCTstatus])Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 1 Send sync message (Type: [MCT status])is Success (err = 0)Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 5 Send sync message (Type: [MCT status])is Success (err = 0)Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 5 Received sync message (Type: [MCTstatus])Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 1 Received sync message (Type: [MCTstatus])Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 5 Received sync message (Type: [MCTstatus])Nov 21 02:43:27 VLL_MCT_SYNC_MSG: VC-ID: 1 Received sync message (Type: [MCTstatus])<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Diagnostic</strong> <strong>Guide</strong> 21353-1002426-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!