ZEFIROM CORRECT PROCEDURE OF DECOMPRESSIONEnglish• Insert the gun clamp (M1).M1Clamp releasedM3Clamp inserted• Move the switch (M2) to the OFF (0) position to stop theequipment.• Release the gun clamp (M1), point the gun at the tank of theproduct and press the trigger to release pressure. At the endof the operation, insert the gun clamp.• Open the recirculation - safety valve (M4) to release theresidual pressure always clockwise.OFFM4H2WARNING:If the equipment is still under pressure after performingthe operations above described becauseof the nozzle or the flexible hose clogged, proceedas follows:• Loosen very slowly the gun nozzle.• Release the clamp.• Point the gun at the container of the productand press the trigger to release pressure.• Loosen very slowly the fitting of connectionfrom the flexible hose to the gun.• Clean or replace the flexible hose and thenozzle.• Disconnect the power supply cable (M3).20