12.07.2015 Views

TENDER FOR PROCUREMENT OF LABORATORY EQUIPMENTS ...

TENDER FOR PROCUREMENT OF LABORATORY EQUIPMENTS ...

TENDER FOR PROCUREMENT OF LABORATORY EQUIPMENTS ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Tea Board/Kolkata/2011-12- QCL Tender Document-OriginalSystem suitable for complying to USP/BPMetabolite ID software/other customized software.etcAutomated calibration and quantitativeoptimization.Automated MS to MS/MS switching a single runwith user selectable criteria.Perform alternating POS/NEG scan in one run.Automated quantification & reporting ofacquired samplesThe software should have 21 CFR Part IIcompliance.LIMS compatibility Software for batch analysis.Computer platformPreferably IBM ,Suitable branded computer,i7 processor with 12 GB DDR3Memory, Up to 1 TB SATA hard drive (7200 RPM)DVD-RW 24” LCD Monitor with suitableOperating SystemLaserJet mono color printer.Gas cylindersArgon gas generator/cylinders, regulators and purifier for the system. Specification with purityand safety data sheet and certificate from competent authorityLow noise and vibration free gas generator, with compressor, should be able to supply all thegases required for the LC-MS/MS instrument at requiredpurity, pressure and flow rate. It should be complete with all accessories such as regulator, gaspurification panel etc. If gas cylinders, minimum two nos.HPLC (Fast LC)Online solvent degasser unitQuaternary System with vaccum degasser (2 channel built in degasser), Auto sampler, columnoven, 2 nos of C18 2.1 x 100 mm 1.7 μm . and 2 nos. 2.X50mm Complete system and MSshould be controlled by MS software.Flow rate – 0.01 - 2ml/min.Syringe should be capable of taking even though the sample is in less quantityIt should have the facility of keeping the sample in acooling condition(temperature range from 4 to 400 COperating pressure – upto 15000 psiFlow accuracy – +0.5% RSDFlow precision – +0.1%Injection vol. – 0.5-10 μlAutosampler The Autosampler must accommodate not less than 50vialsInjection accuracy – More than 0.3% RSDVial capacity – upto 2mlNeedle washing facility – should have needle washing facility from internal and external sideprogrammableBuilt in dilution and derivative system facilitySyringe size –Should accommodate the injection volume stated above.Linearity – > 0.999 coefficient of deviation35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!