VersaFlow Coriolis 1000 Mass Flow Sensor Specification - Honeywell

VersaFlow Coriolis 1000 Mass Flow Sensor Specification - Honeywell VersaFlow Coriolis 1000 Mass Flow Sensor Specification - Honeywell

merkantile.hr
from merkantile.hr More from this publisher
12.07.2015 Views

34-VF-03-03Page 2Technical DataTitanium versions:Operating dataSize T06 T10 T15 T25 T40 T50 T80Flow RateNominal flow rate [kg/h] 950 2700 11250 34500 91500 180000 430000Nominal flow rate [lbs/min] 35 100 400 1250 3300 6600 15800Maximum flow rateMinimum flow rateAccuracyAccuracy, liquidAccuracy, gasRepeatabilityZero stabilityReference conditionsProduct130% of nominal flow rateAccuracy dependant±0.1% of actual measured flow rate±0.5% of actual measured flow rateBetter than 0.05% plus zero stability (includes the combined effects of repeatability, linearity and hysteresis)±0.008% of nominal flow rate with respective sensor sizeWaterTemperature 20°C / 68°FOperating pressureDensity1 bar rel. / 14.5 psigMeasuring range 500…2000 kg/m 3 / 30…125 lbs/ft 3Accuracy ±2 kg/m 3 / ±0.13 lbs/ft 3Accuracy (on-site calibration) ±0.5 kg/m 3 / ±0.033 lbs/ft 3TemperatureMeasuring rangeAccuracy-40…+150°C / -40…+302°F±1°C / ±1.8°FDevice SpecificationSize T06 T10 T15 T25 T40 T50 T80MaterialsMeasuring tubeFlange raised faceFlangesTitaniumTitaniumStainless steel 1.4435 / AISI 316LOuter cylinder (secondary pressure containment) Stainless steel 1.4301 /AISI 304 (optional: stainless steel 1.4435 /AISI 316L)Sensor electronics housingNominal pressure at 20°C or 68°FMeasuring tubeOuter cylinder (secondary pressure containment)TemperatureProcess temperature - flanged connectionsProcess temperature - hygienic type connectionsAmbient temperature - compact versionAmbient temperature - remote versionProcess effects on the sensorStainless steel 1.4435/AISI 316L-1...100 bar rel. / -14.5...1450 psigStandard: -1...63 bar rel. / -14.5...910 psig; Optional: -1...100 bar rel. /-14.5...1450 psig-40...+150°C/ -40...+302°F-20...+150°C/ -4...+302°F-40...+55°C/ -40...+130°F-40...+60°C/ -40...+140°FTemperature 0.002% of the nominal flow rate per 1°C / 0.001% of the nominal flow rate per 1°FPressure0.015% of the nominal flow rate per 1 bar rel. / 0.001% of the nominal flow rate per 1 psig

34-VF-03-03Page 2Technical DataTitanium versions:Operating dataSize T06 T10 T15 T25 T40 T50 T80<strong>Flow</strong> RateNominal flow rate [kg/h] 950 2700 11250 34500 91500 180000 430000Nominal flow rate [lbs/min] 35 100 400 1250 3300 6600 15800Maximum flow rateMinimum flow rateAccuracyAccuracy, liquidAccuracy, gasRepeatabilityZero stabilityReference conditionsProduct130% of nominal flow rateAccuracy dependant±0.1% of actual measured flow rate±0.5% of actual measured flow rateBetter than 0.05% plus zero stability (includes the combined effects of repeatability, linearity and hysteresis)±0.008% of nominal flow rate with respective sensor sizeWaterTemperature 20°C / 68°FOperating pressureDensity1 bar rel. / 14.5 psigMeasuring range 500…2000 kg/m 3 / 30…125 lbs/ft 3Accuracy ±2 kg/m 3 / ±0.13 lbs/ft 3Accuracy (on-site calibration) ±0.5 kg/m 3 / ±0.033 lbs/ft 3TemperatureMeasuring rangeAccuracy-40…+150°C / -40…+302°F±1°C / ±1.8°FDevice <strong>Specification</strong>Size T06 T10 T15 T25 T40 T50 T80MaterialsMeasuring tubeFlange raised faceFlangesTitaniumTitaniumStainless steel 1.4435 / AISI 316LOuter cylinder (secondary pressure containment) Stainless steel 1.4301 /AISI 304 (optional: stainless steel 1.4435 /AISI 316L)<strong>Sensor</strong> electronics housingNominal pressure at 20°C or 68°FMeasuring tubeOuter cylinder (secondary pressure containment)TemperatureProcess temperature - flanged connectionsProcess temperature - hygienic type connectionsAmbient temperature - compact versionAmbient temperature - remote versionProcess effects on the sensorStainless steel 1.4435/AISI 316L-1...100 bar rel. / -14.5...1450 psigStandard: -1...63 bar rel. / -14.5...910 psig; Optional: -1...100 bar rel. /-14.5...1450 psig-40...+150°C/ -40...+302°F-20...+150°C/ -4...+302°F-40...+55°C/ -40...+130°F-40...+60°C/ -40...+140°FTemperature 0.002% of the nominal flow rate per 1°C / 0.001% of the nominal flow rate per 1°FPressure0.015% of the nominal flow rate per 1 bar rel. / 0.001% of the nominal flow rate per 1 psig

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!