TYPICAL INDEX RATIO CATALYST MONITOR ENTRY CONDITIONS:Entry condition Minimum MaximumTime since engine start-up (70 o F start)330 secondsEngine Coolant Temp 170 o F 230 o FIntake Air Temp 20 o F 180 o FTime since entering closed loop fuelInferred Rear HO2S sensor Temperature30 sec900 o FEGR flow (Note: an EGR fault disables EGR) 1% 12%Throttle Position Part Throttle Part ThrottleRate of Change of Throttle Position 0.2 volts /0.050 secVehicle Speed 5 mph 70 mphFuel Level 15%First Air Mass Cell 1.0 lb/min 2.0 lb/minEngine RPM for first air mass cell 1,000 rpm 1,300 rpmEngine Load for first air mass cell 15% 35%Monitored catalyst mid-bed temp. (inferred) for first air mass cell 850 o F 1,200 o FNumber of front O2 switches required for first air mass cell 50Second Air Mass Cell 2.0 lb/min 3.0 lb/minEngine RPM for second air mass cell 1,200 rpm 1,500 rpmEngine Load for second air mass cell 20% 35%Monitored catalyst mid-bed temp. (inferred) for second air mass cell 900 o F 1,250 o FNumber of front O2 switches required for second air mass cell 70Third Air Mass Cell 3.0 lb/min 4.0 lb/minEngine RPM for third air mass cell 1,300 rpm 1,600 rpmEngine Load for third air mass cell 20% 40%Monitored catalyst mid-bed temp. (inferred) for third air mass cell 950 o F 1,300 o FNumber of front O2 switches required for third air mass cell 30(Note: Engine rpm and load values for each air mass cell can vary as a function of the power-to-weight ratioof the engine, transmission and axle gearing and tire size.)TYPICAL MALFUNCTION THRESHOLDS:Rear-to-front O2 sensor switch/index-ratio > 0.75 (bank monitor)Rear-to-front O2 sensor switch/index-ratio > 0.60 (Y-pipe monitor)Rear-to-front O2 sensor switch/index ratio > 0.50 for E10 to > 0.90 for E85 (flex fuel vehicles)FORD MOTOR COMPANY REVISION DATE: APRIL 28, 2004 PAGE 6 OF 131

J1979 CATALYST MONITOR MODE $06 DATATest ID Comp ID Description for J1850 Units$10 $11 Bank 1 switch-ratio and max. limit unitless$10 $21 Bank 2 switch-ratio and max. limit unitless$10 $10 Bank 1 index-ratio and max. limit unitless$10 $20 Bank 2 index-ratio and max. limit unitlessMonitor ID Test ID Description for CAN$21 $80 Bank 1 index-ratio and max. limit unitless$22 $80 Bank 2 index-ratio and max. limit unitlessConversion for J1850 Test ID $10: multiply by 0.0156 to get a value from 0 to 1.0** NOTE: In this document, a monitor or sensor is considered OK if there are no DTCs stored for that componentor system at the time the monitor is running.FORD MOTOR COMPANY REVISION DATE: APRIL 28, 2004 PAGE 7 OF 131

J1979 CATALYST MONITOR MODE $06 DATATest ID Comp ID Description <strong>for</strong> J1850 Units$10 $11 Bank 1 switch-ratio and max. limit unitless$10 $21 Bank 2 switch-ratio and max. limit unitless$10 $10 Bank 1 index-ratio and max. limit unitless$10 $20 Bank 2 index-ratio and max. limit unitlessMonitor ID Test ID Description <strong>for</strong> CAN$21 $80 Bank 1 index-ratio and max. limit unitless$22 $80 Bank 2 index-ratio and max. limit unitlessConversion <strong>for</strong> J1850 Test ID $10: multiply by 0.0156 to get a value from 0 to 1.0** NOTE: In this document, a monitor or sensor is considered OK if there are no DTCs stored <strong>for</strong> that componentor system at the time the monitor is running.FORD MOTOR COMPANY REVISION DATE: APRIL 28, 2004 PAGE 7 OF 131

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!