68/131 <strong>Bosch</strong> <strong>Rexroth</strong> AG | Electric Drivesand Controls<strong>Rexroth</strong> <strong>MKE</strong> Synchronous Motors | <strong>Project</strong> <strong>Planning</strong> <strong>Manual</strong>Connection Techniqueon the motor flange). Protective conductor cross-section see fig. 8-2 " Additionalprotective conductor" on page 66.8.3 Connection according to American Standard (UL)Power and encoder connectionFig.8-5:Connection overview according to American standardThe connection of the <strong>MKE</strong> motors, according to American standard, consistsof the following components:●●●a power connector, incl. connection for temperature sensor and holdingbrake, single-wire constructionencoder connection, standard-cable constructionadditional outside connection for an equipotential bonding conductor (accordingto EN 50014: 1992)The connection cable of the <strong>MKE</strong> motors are to be realised through a specialcable duct into the motor. The ca. 1.5 m long connection cables have to be ledthrough a ¾ inch metal pipe into an approved Ex terminal box (see fig. 8-1 "Connection variants <strong>MKE</strong> motors" on page 65). Standard connection cableslead from an Ex terminal box to a drive control device.