12.07.2015 Views

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

66/131 <strong>Bosch</strong> <strong>Rexroth</strong> AG | Electric Drivesand Controls<strong>Rexroth</strong> <strong>MKE</strong> Synchronous Motors | <strong>Project</strong> <strong>Planning</strong> <strong>Manual</strong>Connection TechniqueThe connection of the PTC resistors for the motor temperature analysis isstipulated in the respective terminal diagram of the drive control devices.DANGERAdditional protective conductorRisk of explosion due to impermissible temperature increase in case ofwrong temperature analysis!⇒ The temperature analysis of the motors must be done with drive control devicesby <strong>Rexroth</strong>!⇒ Connections [1] and [2] of the PTC resistor must be connected to the temperaturemonitoring unit of the drive control device!The <strong>MKE</strong> motors comply with the temperature class T4 according toEN 50014:1992. Thus the maximum permissible surface temperature of theequipment amounts to ≤ 135 °C. The PTC resistors mounted in the <strong>MKE</strong> motorsensure a reliable and safe overtemperature interruption in connection with theplotting system of the drive control devices.Protective-conductor terminalNominalcross-sectionTerminal area<strong>MKE</strong>037<strong>MKE</strong>047<strong>MKE</strong>098<strong>MKE</strong>1182.5 mm²2.5 mm² fine-strand up to4.0 mm² single-strandTemperature resistance of connectioncablesFig.8-2:Additional protective conductorFor using the <strong>MKE</strong> motors in explosive areas, cables with a temperature resistanceof 80 °C (176 °F) have to be used.Ready-made connection cablesFig.8-3:Information sign temperature resistance connection cableThe cables of <strong>Rexroth</strong> given in the selective lists comply with this conditionprecedent.Ready-made connection cables in various length for motors according to EuropeanStandard can be ordered at <strong>Bosch</strong> <strong>Rexroth</strong>.Selective lists of available connection cables chapter 14.2 "Selection of ConnectionCable" on page 121Additional documentation:DOK-CONNEC-CABLE*STAND-AUxx-EN-P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!