12.07.2015 Views

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

Bosch Rexroth IndraDyn S - MKE Project Planning Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

112/131 <strong>Bosch</strong> <strong>Rexroth</strong> AG | Electric Drivesand Controls<strong>Rexroth</strong> <strong>MKE</strong> Synchronous Motors | <strong>Project</strong> <strong>Planning</strong> <strong>Manual</strong>Startup, Operation and Maintenance12.4 Maintenance12.4.1 GeneralSynchronous motors of the MK series operate without wear within the givenoperating conditions. However, operation under unfavorable conditions canlead to limitations in availability.●Increase availability with regular preventive maintenance measures. Observethe instructions in the maintenance schedule of the machine manufacturerand the described service measures.WARNINGDanger of injury due to moving elements! Danger of injury due to hotsurfaces!⇒ Do not carry out any maintenance measures when the machine is running.⇒ During maintenance work, secure the system against restarting and unauthorizeduse.⇒ Do not work on hot surfaces.12.4.2 Cleaning12.4.3 Bearings12.4.4 Connection CablesExcessive dirt, dust or shavings may affect the function of the motors adversely,may in extreme cases even cause a failure of the motors. For that reason, youshould cleanCooling ribs ● the cooling ribs of the motors at regular intervals, in order to obtain a sufficientlylarge heat radiation surface. If the cooling ribs are dirty in part,sufficient heat dissipation via the environmental air is not possible anylonger.An insufficient heat radiation may have undesired consequences. The bearingservice life is reduced by operation at impermissibly high temperatures (thebearing grease is decomposing). Switchoff caused by overtemperature despiteoperation on the basis of selected data, because the appropriate cooling ismissing.The nominal lifetime of the bearings is L10h = 30,000 h according toDIN ISO 281, ed. 1990, provided the permissible radial and axial forces are notexceeded (chapter 9.10.2 "Radial Load, Axial Load" on page 86). Even if thebearings are loaded with higher forces to a minor degree only, their service lifeis affected negatively.The motor bearings should be replaced if●●the nominal bearing service life has been reached,running noises occur.We recommend that bearings be replaced by the <strong>Bosch</strong> <strong>Rexroth</strong>Service.Check connection cables for damage at regular intervals and replace them, ifnecessary.Check any optionally present energy management chains (drag chains) for defects.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!